Sihem Aliouat

Sihem Aliouat

Auto-generated profile, based on publicly available information

Sihem Aliouat

Faculty of Electrical Engineering, University of Science and Technology Houari Boumediene (USTHB), Algiers, Algeria

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
SASihem Aliouat
Sihem Aliouat
ANAzzeddine Nacer
Azzeddine Nacer
KBKamel Boudjit
Kamel Boudjit
SCSofiane Chiheb
Sofiane Chiheb
HMHocine Moulai
Hocine Moulai

3 February 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MGM. Gueraichi
M. Gueraichi
ANA. Nacer
A. Nacer
NDN. Dhahbi-Megriche
N. Dhahbi-Megriche
SAS. Aliouat
S. Aliouat
HMH. Moulai
H. Moulai
HV insulation systems under AC or DC are subject to partial discharges (PD) phenomena which happen randomly and can lead to progressive damage of the dielectric material and/or the outage of the line in which they occur. In order to automate the predictive maintenance, these discharges must be monitored in real time to recognize their energetic nature: low-energy (LE) ones which extinguish by themselves, or contrarily high-energy (HE) ones which can lead to flashovers that imply line outage. One has then to focus on high-energy discharges since they constitute the major risk for the insulation systems and the network stability. For this aim, an experimental investigation was performed for HVDC voltages applied to composite insulators, from levels corresponding to low energy partial discharges to flashover occurrence. Thereby, low noise nanosecond scale measurements are taken simultaneously for voltages, currents and radiated magnetic fields by both types of discharge where a qualitative database was obtained. This paper presents the use of efficient and fast feature selection software that uses the Fisher score as evaluation criterion. The features are selected, and then classified from the most to the least discriminant. The number of the most successive discriminant features which correspond to the best high-energy discharges recognition ratio is then searched. The obtained results from the achieved algorithm, combined with SVM, allow an important reduction of feature number from 25000 to only 37, and an improvement of 4.9% of high-energy discharges recognition when compared to the results obtained before feature selection. The approach is suitable for real time diagnosis of insulator chains close to substations and power plants.