Suhua Zhang

Suhua Zhang

Auto-generated profile, based on publicly available information

Suhua Zhang

Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2018 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
JDJing Dong
Jing Dong
YZYaqin Zhang
Yaqin Zhang
HZHaining Zhang
Haining Zhang
ZJZhijie Jia
Zhijie Jia
SZSuhua Zhang
Suhua Zhang
Xiaogang WangXiaogang Wang
Xiaogang Wang
To investigate corneal densitometry values obtained using Scheimpflug tomography in normal and highly myopic (HM) eyes and to assess the differences in densitometry values between them. Highly myopic and normal corneas were examined using the Pentacam Scheimpflug imaging system. Corneal densitometry was automatically performed over a 12-mm diameter area, which was divided on the basis of annular concentric zones (0–2 mm, 2–6 mm, 6–10 mm, 10–12 mm, total diameter) and depth (anterior layer: inner 120 μm; center layer: from 120 μm to the last 60 μm; posterior layer: last 60 μm; total corneal thickness). A total of 100 normal and 100 HM eyes were enrolled in this study. Upon total corneal thickness densitometry, the HM group was found to have significantly lower values compared with the normal group in 4 annuli, including the 2 mm central zone, 2-6 mm zone, 6–10 mm zone, and 0–12 mm total diameter. Upon anterior layer densitometry, the HM group demonstrated statistically lower values in the 2-6 mm and 6–10 mm zones. Upon densitometry of the central and posterior layers, the HM group was found to have lower values in all annuli. The densitometry map reveals that light backscatter was lower in most portions of the HM cornea than in the normal cornea.

1 July 2016 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
LWLi Wang
Li Wang
SZSuhua Zhang
Suhua Zhang
ZZZhe Zhang
Zhe Zhang
DKDouglas D. Koch
Douglas D. Koch
YJYading Jia
Yading Jia
XLXiaoyan Li
Xiaoyan Li
To evaluate the effectiveness of femtosecond laser penetrating corneal relaxing incisions (CRIs) in reducing corneal astigmatism during cataract surgery. Shanxi Eye Hospital, Taiyuan, Shanxi Province, China. Prospective case series. Using the Lensx laser, CRIs were placed at a diameter of 8.0 mm with a depth of 90%. Corneal astigmatism was measured before surgery and 1 and 3 months after surgery. Vector analyses were performed. To obtain the net corneal changes, the with-the-wound (WTR) and against-the-wound (ATR) changes were calculated along the meridian of the CRI. Multiple regression analysis with generalized estimating equations was used to evaluate the factors contributing to the effectiveness of CRIs. The study comprised 51 eyes. One and 3 months postoperatively, respectively, the mean keratometric astigmatism was reduced significantly by 0.65 diopter (D) and 0.67 D (both P < .05); compared with preoperative corneal astigmatism, the percentage of eyes within ±0.50 D of refractive astigmatism significantly increased by 42.6% and 46.7% (both P < .05) and the mean refractive astigmatism was significantly decreased at 1 month (0.27 @ 93 versus 0.17 × 17) (P < .05) but not at 3 months (0.09 @ 138 versus 0.07 × 172) (P > .05). The mean WTW and ATW changes were -1.05 D and -1.00 D, respectively, and 14.9% and 6.7% of eyes, respectively, were overcorrected. Age, CRI length, and CRI location were factors contributing to net corneal changes. A nomogram is proposed. Femtosecond laser CRIs were effective in reducing corneal astigmatism during cataract surgery, and their long-term effectiveness should be evaluated. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Laboratories, Inc., and Revision Optics, Inc. None of the other authors has a financial or proprietary interest in any material or method mentioned.

1 January 2018 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
XWXiaogang Wang
Xiaogang Wang
ZZZhe Zhang
Zhe Zhang
XLXiaoyan Li
Xiaoyan Li
LXLisha Xie
Lisha Xie
HZHaining Zhang
Haining Zhang
SZSuhua Zhang
Suhua Zhang
PURPOSE: To investigate the wound healing changes of clear corneal incisions performed with a femtosecond laser or a steel bevel knife in cataract surgery using spectral-domain optical coherence tomography. METHODS: Prospectively, consecutive patients undergoing either femtosecond laser–assisted cataract surgery (femtosecond laser group) using the LenSx laser (Alcon Laboratories, Inc., Fort Worth, TX) or traditional cataract surgery using steel blades (control group) were enrolled. The incidence of posterior wound gape, Descemet's membrane detachment, posterior wound retraction, and the inner and outer corneal incision thicknesses were assessed. RESULTS: Compared to the control group, the femtosecond laser group had significantly lower incidences of posterior wound gape at 1 day ( P = .012) and Descemet's membrane detachment at 1 week ( P = .030), 1 month ( P = .048), and 3 months ( P = .048), and a significantly higher incidence of posterior wound retraction at 1 month ( P < .001) and 3 months ( P < .001) postoperatively. The inner and outer corneal incision thicknesses decreased over time in both groups. CONCLUSIONS: The clear corneal incisions created by femtosecond laser demonstrated a lower incidence of posterior wound gape and Descemet's membrane detachment. However, the higher posterior wound retraction incidence, which indicated that there was wound remodeling, was apparent. [ J Refract Surg. 2018;34(1):17–22.]

1 April 2020 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YZYaqin Zhang
Yaqin Zhang
JDJing Dong
Jing Dong
SZSuhua Zhang
Suhua Zhang
BSBin Sun
Bin Sun
XWXiaoliang Wang
Xiaoliang Wang
Xiaogang WangXiaogang Wang
Xiaogang Wang
Purpose. To investigate interdevice agreement among corneal topography/ray-tracing aberrometry (iTrace), partial coherence interferometry (IOLMaster), and Scheimpflug imaging (Pentacam) for the measurement of corneal astigmatism. Methods. The analysis included 90 eyes of 90 subjects without ocular disease. The main outcome measures were corneal cylinder power and axis of astigmatism. All corneal astigmatism measurements were converted to two perpendicular components by using vector analysis. Interdevice agreement was assessed using Bland–Altman analysis, paired sample t-test, and one-way analysis of variance. Results. No significant interdevice difference existed in the astigmatism magnitude, cardinal component, and oblique component (all P>0.05). On comparing iTrace wavefront and simulated keratometry (SimK) astigmatism, significant differences were observed in the astigmatism magnitude and oblique component (both P<0.01), but not in the cardinal component (P=0.687). On comparing Pentacam pupil 3 mm and corneal vertex 3 mm axial astigmatism, significant difference was observed in the astigmatism magnitude (P<0.001), but not in the cardinal and oblique components (both P>0.05). Conclusions. The iTrace, IOLMaster, and Pentacam devices could be used interchangeably for corneal astigmatism measurement. However, the measurement difference in iTrace wavefront and SimK astigmatism and Pentacam pupil 3 mm and vertex 3 mm axial astigmatism should be considered in clinic practice.

16 November 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
ZZZhe Zhang
Zhe Zhang
HLHui Li
Hui Li
JZJing Zhou
Jing Zhou
YZYaqin Zhang
Yaqin Zhang
SZSuhua Zhang
Suhua Zhang
Background: Currently, there is no standard technique for determining corneal astigmatism. The iTrace wavefront aberrometry of cornea calculated steep power and axis based on the best Zernike mathematical fit from all topo data within 4 mm circle. It was supposed to be more accurate than iTrace simulated keratometry which was calculated based on only 4 points on the circle of 3 mm. This aim of this study was to evaluate visual outcomes and rotational stability after toric intraocular lens (IOL) implantation using the wavefront aberrometry of the cornea with iTrace. Setting: Single site in China, Shanxi Eye Hospital, Shanxi, China. Design: Prospective case series. Methods: The study included 85 eyes of 63 patients undergoing phacoemulsification and toric IOL implantation. The IOL power and cylinders were chosen with the help of the iTrace toric planning program using wavefront keratometric astigmatism. Astigmatic changes were assessed using Alpins vector method over a 3-month follow-up period. Results: Preoperative mean corneal topographic astigmatism was 1.91 diopters (D) ± 0.69 (standard deviation). Postoperative mean refractive astigmatism decreased significantly to 0.48 D ± 0.34. Surgical induced astigmatism was 1.73 D ± 0.77 and the mean correction index was 0.89 ± 0.22, showing a slight undercorrection. The proportion of astigmatism ≤0.50 D increased from 0 to 71.8% postoperatively. Conclusions: This is the first study on evaluation of clinical outcomes of toric IOL implantation in corneal astigmatism patients using iTrace wavefront keratometric readings. The findings show that use of iTrace built-in toric calculator is safe and effective for planning toric IOL surgery for wavefront keratometric astigmatism. Trial registration: Current Controlled Trials ISRCTN94956424, Retrospectively registered (Date of registration: 05 February 2020).

19 September 2018
Verified
Book Chapter
Open access
PDF file
Xiaogang WangXiaogang Wang
Xiaogang Wang
JDJing Dong
Jing Dong
SZSuhua Zhang
Suhua Zhang
BSBin Sun
Bin Sun
Optical coherence tomography (OCT), especially anterior segment OCT (AS-OCT), plays an important role in ophthalmology. With the technology evolving from time-domain to spectral-domain, more and more detailed ocular information has become available. Anterior segment OCT provides particularly useful information for cataract surgeons. This chapter focuses mainly on AS-OCT evaluation of eyes before and after cataract surgery. Four aspects including: (1) anterior lens capsule and lens epithelium evaluation using spectral-domain OCT (SD-OCT); (2) investigation of clear corneal incision in femtosecond laser assisted cataract surgery using SD-OCT; (3) capsular block syndrome evaluation before and after treatment using SD-OCT; (4) IOL power calculation in post-myopic excimer laser eyes using SD-OCT, will be discussed in this chapter.