Haipeng Jia

Haipeng Jia

Auto-generated profile, based on publicly available information

Haipeng Jia

Department of Radiology, Qilu Hospital of Shandong University, Jinan 250012, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2018 in Thoracic Cancer
Verified
Journal Article
Open access
PDF file
CLChunhai Li
Chunhai Li
BLBo Liu
Bo Liu
HJHaipeng Jia
Haipeng Jia
ZDZhenyu Dong
Zhenyu Dong
HMHong Meng
Hong Meng
Background: This retrospectively study was conducted to assess the efficiency and safety of computed tomography (CT)‐guided hook wire localization of pulmonary ground‐glass nodules (GGNs) prior to video‐assisted thoracoscopic surgery (VATS).Methods: From 2015 to 2018, a total of 86 patients with 86 pulmonary GGNs underwent preoperative CT‐guided hook wire localization before VATS. The technical details and clinicopathological findings were analyzed.Results: All 86 pulmonary GGNs (25 pure GGNs and 61 part‐solid GGNs) were successfully located and resected. The mean diameter of the GGNs was 1.4 ± 0.4 cm (range 0.6–2.2) and the mean lesion distance to the pleural surface was 7.3 ± 4.3 mm (range 2–19). Complications of hook wire marking included asymptomatic minor pneumothorax in 21 patients (24%) and focal pulmonary hemorrhage in 18 (21%). The median hook wire localization time was 19.1 minutes (range 10–30) and the median VATS time was 49 minutes (range 28–89). Pathology revealed 72 precancerous lesions or primary lung adenocarcinomas, 5 metastatic tumors, and 9 benign lesions.Conclusions: Preoperative localization of small pulmonary GGNs using CT‐guided hook wire was efficient and safe prior to VATS resection.


18 June 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HJHaipeng Jia
Haipeng Jia
CWCuiyan Wang
Cuiyan Wang
GWGuangbin Wang
Guangbin Wang
LQLei Qu
Lei Qu
WCWeibo Chen
Weibo Chen
BZBin Zhao
Bin Zhao
To prospectively evaluate the impact of 3.0 T Cardiac MR imaging using dual-source parallel radiofrequency (RF) transmission with patient-adaptive B1 shimming compared with single-source RF transmission in the RF homogeneity, image contrast and image quality. The study was approved by the local institutional review board, and all subjects provided written informed consent. Fourteen healthy volunteers were examined at 3.0 T MR, with both the conventional single-source and the new dual-source RF transmission. B1 calibrations (RF shimming) of the heart region were performed to acquire a percent of the prescribed flip angle (FA) of B1 maps, which were used for quantitative assessment of RF homogeneity. Contrast ratios (CRs) between ventricular blood pool and septum were calculated on balanced-turbo field echo (B-TFE) cine images. The off-resonance artifacts of cine images were blindly assessed by two radiologists according to a 4-point grading-scale. A significantly lower mean coefficients of variance of the achieved FA with dual-source revealed better RF homogeneity compared to single-source (P = 0.0094). Dual-source RF shimming significantly increased the CRs (P<0.05) and reduced the off-resonance artifacts of B-TFE cine images (P0.65). Dual-source parallel RF transmission significantly improves the RF homogeneity, increases image contrast and reduces image artifacts of cardiac B-TFE images compared to single-source mode. This may be of value in reducing the observer-dependence of cardiac MR images and enhancing diagnostic confidence for clinical practice using CMR at 3.0 T.

10 July 2019 in Thoracic Cancer
Verified
Journal Article
Open access
PDF file
HJHaipeng Jia
Haipeng Jia
JTJie Tian
Jie Tian
BLBo Liu
Bo Liu
HMHong Meng
Hong Meng
FPFengmin Pan
Fengmin Pan
CLChunhai Li
Chunhai Li
Background To evaluate the efficacy and safety of artificial pneumothorax with position adjustment for computed tomograpy (CT)‐guided percutaneous transthoracic microwave ablation (MWA) of small subpleural lung tumors. Methods Fifty‐six patients with small subpleural lung tumors (< 3.0 cm) entered the study and underwent CT‐guided MWA with (group I: 24 patients with 24 tumors) or without (group II: 32 patients with 34 tumors) the support of artificial pneumothorax. Follow‐up contrast‐enhanced CT scans were reviewed. Pain VAS (visual analog scale) scores at, during, and after ablation were compared between the two groups. Technical success, technique efficacy, local tumor control and complications were compared. Results Creation of the artificial pneumothorax was achieved for 24/24 (100%) in group I and no complication related to the procedure was observed. Technical success of MWA was achieved for all 58 tumors. Primary efficacy of MWA was achieved in 23 of 24 tumors (95.8%) treated in group I, and 32 of 34 tumors (94.1%) treated in group II (P = 0.771). The 12‐month local tumor control was achieved in 87.5% (21/24) in group I compared with 88.2% (30/34) in group II (P = 0.833). Pain VAS scores in group I were significantly decreased after the pneumothorax induction at, during, and after ablation compared with group II (P < 0.05). There was no significant difference in MWA‐related complications (P > 0.05). Conclusion Artificial pneumothorax with position adjustment for CT‐guided MWA is effective and may be safely applied to small subpleural lung tumors. Artificial pneumothorax is a reliable therapy for pain relief.

6 August 2021 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
CLChunhai Li
Chunhai Li
DWDexiang Wang
Dexiang Wang
FYFengxia Yang
Fengxia Yang
YSYang Song
Yang Song
XYXuejuan Yu
Xuejuan Yu
WZWei Zhou
Wei Zhou
Background: We aim to analyze the risk factors for pneumothorax associated with computed tomography (CT)-guided percutaneous core needle biopsy (PCNB) of the lung. Whether the lung function characteristics are related to pneumothorax is unclear. Methods: We retrospectively evaluated 343 patients who received CT-guided pulmonary PCNBs and underwent preoperative pulmonary function testing. Demographical, lesion-related, procedure-related features and histopathological diagnosis, as well as results of pulmonary function test were analyzed as risk factors of pneumothorax Results: Variables associated with higher rate of pneumothorax were location of lesion, presence of emphysema, and dwell time. The proportion of middle lobe, lingular, or lower lobe lesions in pneumothorax group (30/50, 60.0%) is higher than non-pneumothorax group (113/293, 38.6%). The incidence of emphysema in pneumothorax group was significantly higher than that in non-pneumothorax group (34.0% vs. 7.5%). Obstructive pulmonary function abnormalities, not restrictive, mixed ventilation function abnormalities and small airway dysfunction, correlated with pneumothorax. Multivariate logistic regression analysis showed lower location of lesion sampled and presence of emphysema were independent predictors of pneumothorax. Although dwell time, FEV1/FVC ratio, FEF50%, FEF75% and FEF25–75% were significantly correlated with pneumothorax on univariate analysis, these were not confirmed to be independent predictors. Conclusions: Patients with obstructive pulmonary dysfunction have a higher risk of pneumothorax. Presence of emphysema was the most important predictor of pneumothorax, followed by location of lesion.

15 December 2016 in PeerJ
Verified
Journal Article
Open access
PDF file
HWHaipeng Wang
Haipeng Wang
BZBin Zhao
Bin Zhao
HJHaipeng Jia
Haipeng Jia
FGFei Gao
Fei Gao
JZJunyu Zhao
Junyu Zhao
CWCuiyan Wang
Cuiyan Wang
Background: Fulminant myocarditis (FM) is an inflammatory disease of the myocardium that results in ventricular systolic dysfunction and causes acute-onset heart failure. Cardiac magnetic resonance (CMR) has become the primary noninvasive tool for the diagnosis and evaluation of myocarditis. The aim of our study was to assess the CMR findings at different course of FM and the short-term outcomes of fulminant myocarditis (FM) in children. Methods: Eight FM children with CMR examinations were included in our study. Initial baseline CMR was performed 10 days (range, 7–20 days) after onset of FM and follow-up CMR after 55 days (range, 33–75 days). Cardiac morphology and function and myocardial tissue characterization at baseline and follow-up CMR were compared using paired T-test and Mann–Whitney U test. The clinical data and initial CMR findings were also compared to predict short-term outcomes. Results: The median age of eight FM children was 8.5 years old (range, 3–14). The initial CMR findings were most common with early gadolinium enhancement (EGE, 100%), followed by signal increasing on T2WI and late gadolinium enhancement (LGE, 87.5%), increased septal thickness (75.0%) and increased left ventricle ejection fraction (LVEF, 50.0%). Only three LGE (37.5%), one signal increasing on T2WI (12.5%) and one increased LVEF (12.5%) were found at follow-up. Statistically significant differences were found between initial and follow-up CMR abnormalities in the septal thickness, left ventricular end-diastolic diameter (LVEDD), end-systolic volume (ESV), LVEF, left ventricular mass, T2 ratio and LGE area (P = 0.011, P = 0.042, P = 0.016, P = 0.001, P = 0.003, P = 0.011, P = 0.020). The children with full recovery performed higher incidence of III° atrioventricular block (AVB, five cases VS 0 case) and smaller LGE area (104.0 ± 14.5 mm2 VS 138.0 ± 25.2 mm2) at baseline CMR. Discussion: The CMR findings of FM in children were characteristic and useful for early diagnosis. Full recovery of clinical manifestations, immunological features and CMR findings could be found in most FM children. The presence of III° AVB and smaller LGE area at baseline CMR might indicate better short-term outcomes.