Hong Meng

Hong Meng

Auto-generated profile, based on publicly available information

Hong Meng

Department of Radiology, Qilu Hospital of Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Psychiatry Research
Verified
Journal Article
Closed access
BLBo Liu
Bo Liu
GWGuangbin Wang
Guangbin Wang
DGDongmei Gao
Dongmei Gao
FGFei Gao
Fei Gao
BZBin Zhao
Bin Zhao
RDRae Caroline D
Rae Caroline D

26 July 2018 in Thoracic Cancer
Verified
Journal Article
Open access
PDF file
CLChunhai Li
Chunhai Li
BLBo Liu
Bo Liu
HJHaipeng Jia
Haipeng Jia
ZDZhenyu Dong
Zhenyu Dong
HMHong Meng
Hong Meng
Background: This retrospectively study was conducted to assess the efficiency and safety of computed tomography (CT)‐guided hook wire localization of pulmonary ground‐glass nodules (GGNs) prior to video‐assisted thoracoscopic surgery (VATS).Methods: From 2015 to 2018, a total of 86 patients with 86 pulmonary GGNs underwent preoperative CT‐guided hook wire localization before VATS. The technical details and clinicopathological findings were analyzed.Results: All 86 pulmonary GGNs (25 pure GGNs and 61 part‐solid GGNs) were successfully located and resected. The mean diameter of the GGNs was 1.4 ± 0.4 cm (range 0.6–2.2) and the mean lesion distance to the pleural surface was 7.3 ± 4.3 mm (range 2–19). Complications of hook wire marking included asymptomatic minor pneumothorax in 21 patients (24%) and focal pulmonary hemorrhage in 18 (21%). The median hook wire localization time was 19.1 minutes (range 10–30) and the median VATS time was 49 minutes (range 28–89). Pathology revealed 72 precancerous lesions or primary lung adenocarcinomas, 5 metastatic tumors, and 9 benign lesions.Conclusions: Preoperative localization of small pulmonary GGNs using CT‐guided hook wire was efficient and safe prior to VATS resection.


10 July 2019 in Thoracic Cancer
Verified
Journal Article
Open access
PDF file
HJHaipeng Jia
Haipeng Jia
JTJie Tian
Jie Tian
BLBo Liu
Bo Liu
HMHong Meng
Hong Meng
FPFengmin Pan
Fengmin Pan
CLChunhai Li
Chunhai Li
Background To evaluate the efficacy and safety of artificial pneumothorax with position adjustment for computed tomograpy (CT)‐guided percutaneous transthoracic microwave ablation (MWA) of small subpleural lung tumors. Methods Fifty‐six patients with small subpleural lung tumors (< 3.0 cm) entered the study and underwent CT‐guided MWA with (group I: 24 patients with 24 tumors) or without (group II: 32 patients with 34 tumors) the support of artificial pneumothorax. Follow‐up contrast‐enhanced CT scans were reviewed. Pain VAS (visual analog scale) scores at, during, and after ablation were compared between the two groups. Technical success, technique efficacy, local tumor control and complications were compared. Results Creation of the artificial pneumothorax was achieved for 24/24 (100%) in group I and no complication related to the procedure was observed. Technical success of MWA was achieved for all 58 tumors. Primary efficacy of MWA was achieved in 23 of 24 tumors (95.8%) treated in group I, and 32 of 34 tumors (94.1%) treated in group II (P = 0.771). The 12‐month local tumor control was achieved in 87.5% (21/24) in group I compared with 88.2% (30/34) in group II (P = 0.833). Pain VAS scores in group I were significantly decreased after the pneumothorax induction at, during, and after ablation compared with group II (P < 0.05). There was no significant difference in MWA‐related complications (P > 0.05). Conclusion Artificial pneumothorax with position adjustment for CT‐guided MWA is effective and may be safely applied to small subpleural lung tumors. Artificial pneumothorax is a reliable therapy for pain relief.

1 September 2016 in Clinical Endocrinology
Verified
Journal Article
Closed access
PDF file
BLBo Liu
Bo Liu
HYHuan Yang
Huan Yang
FGFei Gao
Fei Gao
QWQing Wang
Qing Wang
BZBin Zhao
Bin Zhao
RERichard A.E. Edden
Richard A.E. Edden

1 May 2019 in Thoracic Cancer
Verified
Journal Article
Open access
PDF file
BLBo Liu
Bo Liu
JFJie Fang
Jie Fang
HJHaipeng Jia
Haipeng Jia
ZSZhigang Sun
Zhigang Sun
JLJian Liao
Jian Liao
CLChunhai Li
Chunhai Li
Background: This study prospectively investigated the efficacy and radiation dose of ultralow dose computed tomography (CT)‐guided hook‐wire localization (HWL) at 100 kV with tin filtration (100Sn kV) for small solitary pulmonary nodules.Methods: All HWL procedures were performed on a third generation dual‐source CT system. Eighty‐eight consecutive patients undergoing CT‐guided HWL were randomly assigned to standard dose CT (Group A: n = 44; reference 110 kV and 50 mA) or ultralow dose CT (Group B: n =44; 100Sn kV and 96 mA) protocols. The technical success rate, complications, subjective image quality, and radiation dose were compared between the groups.Results: The mean volume CT dose index and total dose‐length product were significantly lower in Group B compared to Group A (0.32 mGy vs. 3.2 ± 1.1 mGy and 12.1 ± 0.97 mGy‐cm vs. 120 ± 40.6 mGy‐cm; P < 0.001). The effective dose in Group B was significantly lower than in Group A (0.17 ± 0.01 mSv vs. 1.68 ± 0.57 mSv, ‐89.8%; P < 0.001). The technical success rates were 100% for both groups. There were no significant differences in complication rates between the protocols (P > 0.05). The image quality of ultralow dose CT met the requirements for HWL procedure.Conclusion: Ultralow dose CT‐guided HWL of solitary pulmonary nodules performed at 100Sn kVp spectral shaping significantly reduced the radiation dose compared to standard dose CT, with high technical success and acceptable patient safety.