This paper presents a non-conductor-contact surface wave-based reflectometry technique to detect and locate missing or damaged insulation and/or jacket of electrical cables. The described sensor may be uniquely and practically implemented on live cables as a non-destructive evaluation (NDE) method since it may be applied to the outer insulation/jacket of a cable and requires no direct contact to the conductor. The innovation lies in a high-frequency surface wave launcher that can introduce broadband signals in the GHz frequencies that insure maximum electromagnetic (EM) energy localization within the insulation and/or jacket material. By further processing the reflection data in the frequency domain, the location and severity of insulation damage is detected. Simulated results of thin, thick, short, and long cables show the results expected from small, medium, and large damage regions. For example, the detection of 40 mm-long damage region at 40 m distance on a 50 m long cable (2.44 cm diameter) is demonstrated. Experimental results are presented that validate simulation findings.
This letter introduces the study and application of a conformal surface wave launcher array to detect miniature insulation and/or jacket damage on unshielded cables. Simulation and experimental results are presented that demonstrate that with the proposed concept very small instances of damage at various distances along power cables can be detected. Effects of damage detection feasibility in the presence of other cables in proximity and for cables containing semiconducting screen are also presented.
The stopband frequencies of a single column mushroom EBG structure between two vertical wire monopole antennas were determined using HFSS, an existing model and a proposed new model. The results show that the stop band frequencies calculated using the proposed new model is more accurate compared to those obtained from the existing model especially for larger patch width to height ratios (w/h>2.1).
22 November 2019 in International Journal of RF and Microwave Computer-Aided Engineering
A new lightweight multilayer mushroom EBG is proposed to significantly improve the isolation between collocated aircraft L‐band blade monopole antennas. Isolation improvement between two L‐bands (960‐1220 MHz) blade monopoles of nearly 20 dB is obtained with a three‐layer EBG design without requiring any redesigning or tuning of the antennas. Since the proposed EBG structure only contains very thin dielectric sheets and foam substrates it would be a lightweight structure. Moreover, the EBG being a stand‐alone structure from the antenna it can be designed, built, and placed between the antennas as an add‐on device to significantly improve antenna isolation over a relatively wide bandwidth (25%). An experimental EBG structure was built and tested demonstrating wideband isolation improvement performance.
*Cable insulation aging accelerates the degradation process of cable polymer materials thereby creating premature failures. Regular cable health monitoring to identify insulation degradation at an early stage is important to ensure uninterrupted and reliable service. This paper presents a combined full-wave and circuit based simulation study to investigate the important topic of