Abdelhady Ghanem

Abdelhady Ghanem

Auto-generated profile, based on publicly available information

Abdelhady Ghanem

Electrical Engineering Department, Mansoura University, Mansoura, Egypt

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2017 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
AGAbdelhady Ghanem
Abdelhady Ghanem
MRMohamed Rashed
Mohamed Rashed
MSMark Sumner
Mark Sumner
MEMohamed A. Elsayes
Mohamed A. Elsayes
IMIbrahim I.I. Mansy
Ibrahim I.I. Mansy
Power system (grid) impedance is time varying due to the changing structure of the power system configuration and it can have a considerable influence on the control and stability of grid connected converters. This study presents an online grid impedance estimation method using the output switching current ripple of a space vector pulse‐width modulator‐based grid connected converter. The proposed impedance estimation method is derived from the discretised system model using two consecutive samples within a single switching period. The estimated impedance is used for islanding detection and online current controller parameter tuning. Theoretical analysis and MATLAB simulation results are presented to verify the proposed method and its effectiveness is validated using experimental testing.

1 December 2021 in Applied Energy
Verified
Journal Article
Closed access
Sayed AbulanwarSayed Abulanwar
Sayed Abulanwar
AGAbdelhady Ghanem
Abdelhady Ghanem
MRMohammad E.M. Rizk
Mohammad E.M. Rizk
WHWeihao Hu
Weihao Hu

28 February 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZYZheng Yin
Zheng Yin
FDFujin Deng
Fujin Deng
AGAbdelhady Ghanem
Abdelhady Ghanem
SKSahar S. Kaddah
Sahar S. Kaddah
Sayed AbulanwarSayed Abulanwar
Sayed Abulanwar
The model predictive control (MPC) is sensitive to parameter variations in LCL -filtered voltage source inverters (VSIs). To improve the robustness of the MPC, this article proposes a parameter-less prediction and reference-based predictive control (PLPR-PC) for LCL -filtered VSIs, where the proposed PLPR-PC not only obtains the parameter-less predictions by measuring and updating all current-voltage gradients but also obtains the parameter-less references by using the phase differences between measured currents and voltages. The proposed PLPR-PC effectively eliminates parametric effects on both prediction and reference calculations and thereby improves the robustness of grid current for LCL -filtered VSIs under parameter variations. The 30-kW simulation and experimental prototype are built up to verify the feasibility and performance of the proposed PLPR-PC.

6 August 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AGAhmed S. Gardouh
Ahmed S. Gardouh
Sayed AbulanwarSayed Abulanwar
Sayed Abulanwar
FDFujin Deng
Fujin Deng
EGEid Abdelbaki Gouda
Eid Abdelbaki Gouda
AGAbdelhady Ghanem
Abdelhady Ghanem
This article proposes a novel real-time fault diagnosis approach for open-switch faults of three-phase pulsewidth modulated voltage source inverter induction motor drive system. The diagnosis method relies only on the observed current via processing the extracted dc components and current absolutes using dynamic resonant filters (DRFs). By employing the ratio between the extracted dc components along with the dc component of absolute line currents and absolute line currents sum, 33 different types of faults can be detected and discriminated effectively. A fuzzy logic-based subsystem is dedicated to accurate reporting of different fault scenarios and manipulating the detection delay caused by the extracted dc component oscillation introduced by the DRFs. The proposed approach is parameter-free, fast, reluctant to noise presence, applicable for a wide range of switching frequencies, and independent of load-level or transient variations. Besides, it is suitable for any type of control technique either open or closed loop without any excessive sensors. Extensive experimental and time-domain investigations are examined, and the obtained results reveal the effectiveness of the proposed fault detection method.

1 March 2023 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
ARAfaf Rabie
Afaf Rabie
AGAbdelhady Ghanem
Abdelhady Ghanem
SKSahar S. Kaddah
Sahar S. Kaddah
MEMagdi Mohamed Ali El-Saadawi
Magdi Mohamed Ali El-Saadawi
Grid connected electric vehicles (EVs) can provide energy quality services to ease intermittent renewable energy sources dependent, enhance grid stability performance, reliability and load balancing in the power system. Moreover, incorporating sufficient EVs into the power grid will assist reduce greenhouse gases. However, the unrestrained EVs charging impact the raise of peak request, frequency deflection, voltage instability, power quality from the acceptable limits. It can also cause overloading of the power system equipment and an increase in power losses. In this paper, the influences EV technologies on various energy systems, control scheme strategy, benefits, and motivational challenges are investigated. An overview of the impacts of uncontrolled EV loading on the electric power system and how controlled charging becomes benefit impacts is presented. Moreover, a review of the controlled charge and discharge benefits of EVs and the electrical serving involved in reduction of frequency deviation, voltage stability, power quality improvement is introduced. This review shows that integration of optimal control of EVs with a suitable optimization technique can improve and provide on time multi ancillary services of EV integrated with weak grid. In addition, this review provides research tracks which can be followed by researchers.

8 September 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MRMohammad E. M. Rizk
Mohammad E. M. Rizk
Sayed AbulanwarSayed Abulanwar
Sayed Abulanwar
AGAbdelhady Ghanem
Abdelhady Ghanem
Zhe ChenZhe Chen
Zhe Chen
This paper proposes a novel layout for a grid-connected DC wind farm (DCWF) and investigates the performance under continuous operation and direct lightning strikes particularly for high soil resistivity. The DCWF employs internal dc grid that supplies generated power to the host AC utility through high voltage direct current (HVDC) transmission link. The proposed layout ensures sustainability of power supply against potential interruptions of DCWFs either during normal conditions or lightning incidents to comply with grid codes regulations. During continuous operation, the proposed layout safeguards the entire DCWF cables against flow of return currents to avert derating of conductor ampacity. Besides, protects WT nacelle switchgear and entire interface converters against hazards of surge currents. Furthermore, an effective grounding system design is proposed to introduce a low impedance path for system return currents, minimize voltage drop across grounding impedance and thus maximize DCWF delivered power to the grid. A detailed system that sufficiently represents models of system cables, grounding network and interface converters is built to verify the proposed scheme significance. The obtained results assure the capability of proposed layout to cease return currents via cable sheath during continuous operation and provide superior mitigation of lightning-associated transient voltages and currents.