This article proposes a novel real-time fault diagnosis approach for open-switch faults of three-phase pulsewidth modulated voltage source inverter induction motor drive system. The diagnosis method relies only on the observed current via processing the extracted dc components and current absolutes using dynamic resonant filters (DRFs). By employing the ratio between the extracted dc components along with the dc component of absolute line currents and absolute line currents sum, 33 different types of faults can be detected and discriminated effectively. A fuzzy logic-based subsystem is dedicated to accurate reporting of different fault scenarios and manipulating the detection delay caused by the extracted dc component oscillation introduced by the DRFs. The proposed approach is parameter-free, fast, reluctant to noise presence, applicable for a wide range of switching frequencies, and independent of load-level or transient variations. Besides, it is suitable for any type of control technique either open or closed loop without any excessive sensors. Extensive experimental and time-domain investigations are examined, and the obtained results reveal the effectiveness of the proposed fault detection method.
21 July 2023 in International Journal of Hydrogen Energy
In this paper, a comprehensive methodology based on coot bird metahurestic optimizer called CBMO is presented aiming to demonstrate the performance of solar units under various operating and loading scenarios. The CBMO is capable to deal with different complicated behavior in both harmonized or disorderly phases and can define its major parameters with proofed indicators. It can convey from exploration state to exploitation state to realize a fast and better convergence without trapping in local minima. At first stage of this effort, the optimal values of uncertain parameters of well-known benchmarking PV units under study are cropped with compulsory validations and comparisons. It can be mentioned here both single- and double-diode models of such units are utilized, and their unknown parameters are emphasized. Then, a Simulink detailed model is built-up employing the obtained parameters with various types of connected loads such as static resistive load and dynamic DC motor to appraise the operating performance of such units. It is worth mentioning that the performance of solar units under varied sun radiations and cell temperatures are made along the presented work. To sum up, it can be empathized that the CBMO performs well, and its results are very competitive to those available in the literature.
5 January 2025 in Energy Conversion and Management: X