1 January 2021 in Neuroscience Letters
1 August 2019 in Human Movement Science
29 September 2022 in IEEE Transactions on Biomedical Engineering
Objective: In this study, we aimed to develop a novel electromyography (EMG)-based neural machine interface (NMI), called the Neural Network-Musculoskeletal hybrid Model (N2M2), to decode continuous joint angles. Our approach combines the concepts of machine learning and musculoskeletal modeling. Methods: We compared our novel design with a musculoskeletal model (MM) and 2 continuous EMG decoders based on artificial neural networks (ANNs): multilayer perceptrons (MLPs) and nonlinear autoregressive neural networks with exogenous inputs (NARX networks). EMG and joint kinematics data were collected from 10 non-disabled and 1 transradial amputee subject. The offline performance tested across 3 different conditions (i.e., varied arm postures, shifted electrode locations, and noise-contaminated EMG signals) and online performance for a virtual postural matching task was quantified. Finally, we implemented the N2M2 to operate a prosthetic hand and tested functional task performance. Results: The N2M2 made more accurate predictions than the MLP in all postures and electrode locations (p < 0.003). For estimated MCP joint angles, the N2M2 was less sensitive to noisy EMG signals than the MM or NARX network with respect to error (p < 0.032) as well as the NARX network with respect to correlation (p = 0.007). Additionally, the N2M2 had better online task performance than the NARX network (p ≤ 0.030). Conclusion: Overall, we have found that combining the concepts of machine learning and musculoskeletal modeling has resulted in a more robust joint kinematics decoder than either concept individually. Significance: The outcome of this study may result in a novel, highly reliable controller for powered prosthetic hands.
21 October 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
This study aimed to develop a novel framework to quickly personalize electromyography (EMG)-driven musculoskeletal models (MMs) as efferent neural interfaces for upper limb prostheses. Our framework adopts a generic upper-limb MM as a baseline and uses an artificial neural network-based policy to fine-tune the model parameters for MM personalization. The policy was trained by reinforcement learning (RL) to heuristically adjust the MM parameters to maximize the accuracy of estimated hand and wrist motions from EMG inputs. Our present framework was compared to the baseline MM and a widely used MM parameter optimization method: simulated annealing (SA). An offline evaluation was performed to first quantify the time required for MM personalization and the kinematics estimation accuracy of personalized MMs based on data collected from able-bodied subjects. Then, in an online evaluation, additional human subjects, including an individual with a transradial amputation, performed a virtual hand posture matching task using generic and personalized MMs. Results showed that compared to the baseline generic MM, personalized MMs estimated joint motion with lower error in both offline ( p <0.05) and online tests ( p =0.014), demonstrating the benefit of MM personalization. The RL-based framework performed model optimization in under one second on average in cases that took SA over 13 minutes and yielded comparable kinematics estimations both offline and online. Hence, our present personalization framework can be a practical solution for the daily use of EMG-driven MMs in prostheses or other assistive devices.
13 October 2020 in Scientific Reports
Physical therapists (PT) and clinicians must be skilled in identifying gait features through observation to assess motor deficits in patients and intervene appropriately. Inconsistent results in the literature have led researchers to question how clinical experience influences PT’s gait perception and to seek the key kinematic features that should be trained to enhance PT’s skill. Thus, this study investigated (1) what are the informative kinematic features that allow gait-deviation perception in amputee gait and (2) whether there are differences in observational gait skills between PT and individuals with less clinical experience (PT students [PTS] and Novices). We introduced a new method that combines biological motion and principal component analysis to gradually mesh amputee and typical walking patterns. Our analysis showed that on average the accuracy rate in identifying gait deviations between PT and PTS was similar and better than Novices. Also, we found that PT’s experience was demonstrated by their better perception of gait asymmetry. The extracted principal components demonstrated that the major gait deviation of amputees was the medial–lateral body sway and spatial gait asymmetry.
22 September 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Although advanced wearable robots can assist human wearers, their internal faults (i.e., sensors or control errors) also pose a challenge. To ensure safe wearer-robot interactions, how internal errors by the prosthesis limb affect the stability of the user-prosthesis system, and how users react and compensate for the instability elicited by internal errors are imperative. The goals of this study were to 1) systematically investigate the biomechanics of a wearer-robot system reacting to internal errors induced by a powered knee prosthesis (PKP), and 2) quantify the error tolerable bound that does not affect the user’s gait stability. Eight non-disabled participants and two unilateral transfemoral amputees walked on a pathway wearing a PKP, as the controller randomly switched the control parameters to disturbance parameters to mimic the errors caused by locomotion mode misrecognition. The size of prosthesis control errors was systematically varied to determine the error tolerable bound that disrupted gait stability. The effect of the error was quantified based on the 1) mechanical change described by the angular impulse applied by the PKP, and 2) overall gait instability quantified using human perception, angular momentum, and compensatory stepping. The results showed that the error tolerable bound is dependent on the gait phase and the direction of torque change. Two balance recovery strategies were also observed to allow participants to successful respond to the induced errors. The outcomes of this study may assist the future design of an auto-tuning algorithm, volitionally-controlled powered prosthetic legs, and training of gait stability.