This research investigates defect initiation and progression in Glass Fibre Reinforced Polymer (GFRP) with three distinct fibre volume fractions Vf: 30%, 55%, and 70%. The study combines multi-physics simulation, using Ansys Mechanical with Acoustic Emission (AE) technique to characterise the material's mechanical and dynamic response under loading conditions. Higher Vf demonstrate improved mechanical properties with reduced flexural modulus and generates increased AE activities that enhance defect detectability. The simulation was based on ASTM D2412, ASTM D3175 and ISO 9969 standards encompassing Harmonic Response, Static and Transient Structural analyses to predict stress-strain behaviour and dynamic properties. The methodology focused on the development of a framework to correlate AE signal parameters with predicted failure mechanisms within the composite rings. The key findings reveal defect initiation threshold for each Vf, demonstrating that higher fibre content increases stiffness by 7% at 30% Vf compared to 20% at 55% Vf, but shifts the failure mechanism from matrix cracking to fibre fracture and alters the sensitivities of the AE sensor to damage detection. The findings provide a critical insight for predictive maintenance and structural health monitoring of composite materials, which allows sensors to detect matrix crazing earlier, before a visual crack appears on the structure.