Thomas Duc

Thomas Duc

Auto-generated profile, based on publicly available information

Thomas Duc

ENGIE Green France, 6 rue Alexander Fleming, 69007 Lyon, France

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
ESEric Simley
Eric Simley
PFPaul Fleming
Paul Fleming
NGNicolas Girard
Nicolas Girard
LALucas Alloin
Lucas Alloin
EGEmma Godefroy
Emma Godefroy
TDThomas Duc
Thomas Duc
Wake steering is a wind farm control strategy in which upstream wind turbines are misaligned with the wind to redirect their wakes away from downstream turbines, thereby increasing the net wind plant power production and reducing fatigue loads generated by wake turbulence. In this paper, we present results from a wake-steering experiment at a commercial wind plant involving two wind turbines spaced 3.7 rotor diameters apart. During the 3-month experiment period, we estimate that wake steering reduced wake losses by 5.6 % for the wind direction sector investigated. After applying a long-term correction based on the site wind rose, the reduction in wake losses increases to 9.3 %. As a function of wind speed, we find large energy improvements near cut-in wind speed, where wake steering can prevent the downstream wind turbine from shutting down. Yet for wind speeds between 6–8 m/s, we observe little change in performance with wake steering. However, wake steering was found to improve energy production significantly for below-rated wind speeds from 8–12 m/s. By measuring the relationship between yaw misalignment and power production using a nacelle lidar, we attribute much of the improvement in wake-steering performance at higher wind speeds to a significant reduction in the power loss of the upstream turbine as wind speed increases. Additionally, we find higher wind direction variability at lower wind speeds, which contributes to poor performance in the 6–8 m/s wind speed bin because of slow yaw controller dynamics. Further, we compare the measured performance of wake steering to predictions using the FLORIS (FLOw Redirection and Induction in Steady State) wind farm control tool coupled with a wind direction variability model. Although the achieved yaw offsets at the upstream wind turbine fall short of the intended yaw offsets, we find that they are predicted well by the wind direction variability model. When incorporating the expected yaw offsets, estimates of the energy improvement from wake steering using FLORIS closely match the experimental results.

22 May 2019 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
TDThomas Duc
Thomas Duc
OCOlivier Coupiac
Olivier Coupiac
NGNicolas Girard
Nicolas Girard
Gregor GiebelGregor Giebel
Gregor Giebel
TGTuhfe Göçmen
Tuhfe Göçmen
In this paper, a new calculation procedure to improve the accuracy of the Jensen wake model for operating wind farms is proposed. In this procedure, the wake decay constant is updated locally at each wind turbine based on the turbulence intensity measurement provided by the nacelle anemometer. This procedure was tested against experimental data at the Sole du Moulin Vieux (SMV) onshore wind farm in France and the Horns Rev-I offshore wind farm in Denmark. Results indicate that the wake deficit at each wind turbine is described more accurately than when using the original model, reducing the error from 15 % to 20 % to approximately 5 %. Furthermore, this new model properly calibrated for the SMV wind farm is then used for coordinated control purposes. Assuming an axial induction control strategy, and following a model predictive approach, new power settings leading to an increased overall power production of the farm are derived. Power gains found are on the order of 2.5 % for a two-wind-turbine case with close spacing and 1 % to 1.5 % for a row of five wind turbines with a larger spacing. Finally, the uncertainty of the updated Jensen model is quantified considering the model inputs. When checked against the predicted power gain, the uncertainty of the model estimations is seen to be excessive, reaching approximately 4 %, which indicates the difficulty of field observations for such a gain. Nevertheless, the optimized settings are to be implemented during a field test campaign at SMV wind farm in the scope of the national project SMARTEOLE.

8 September 2022 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
TGTuhfe Göçmen
Tuhfe Göçmen
FCFilippo Campagnolo
Filippo Campagnolo
TDThomas Duc
Thomas Duc
IEIrene Eguinoa
Irene Eguinoa
Søren AndersenSøren Andersen
Søren Andersen
JMJohan Meyers
Johan Meyers
Wind farm flow control (WFFC) is a topic of interest at several research institutes and industry and certification agencies worldwide. For reliable performance assessment of the technology, the efficiency and the capability of the models applied to WFFC should be carefully evaluated. To address that, the FarmConners consortium has launched a common benchmark for code comparison under controlled operation to demonstrate its potential benefits, such as increased power production. The benchmark builds on available data sets from previous field campaigns, wind tunnel experiments, and high-fidelity simulations. Within that database, four blind tests are defined and 13 participants in total have submitted results for the analysis of single and multiple wakes under WFFC. Here, we present Part I of the FarmConners benchmark results, focusing on the blind tests with large-scale rotors. The observations and/or the model outcomes are evaluated via direct power comparisons at the upstream and downstream turbine(s), as well as the power gain at the wind farm level under wake steering control strategy. Additionally, wake loss reduction is also analysed to support the power performance comparison, where relevant. The majority of the participating models show good agreement with the observations or the reference high-fidelity simulations, especially for lower degrees of upstream misalignment and narrow wake sector. However, the benchmark clearly highlights the importance of the calibration procedure for control-oriented models. The potential effects of limited controlled operation data in calibration are particularly visible via frequent model mismatch for highly deflected wakes, as well as the power loss at the controlled turbine(s). In addition to the flow modelling, the sensitivity of the predicted WFFC benefits to the turbine representation and the implementation of the controller is also underlined. The FarmConners benchmark is the first of its kind to bring a wide variety of data sets, control settings, and model complexities for the (initial) assessment of farm flow control benefits. It forms an important basis for more detailed benchmarks in the future with extended control objectives to assess the true value of WFFC.

15 February 2022 in EGUsphere
Verified
Preprint
Open access
PDF file
TGTuhfe Göçmen
Tuhfe Göçmen
FCFilippo Campagnolo
Filippo Campagnolo
TDThomas Duc
Thomas Duc
IEIrene Eguinoa
Irene Eguinoa
Søren AndersenSøren Andersen
Søren Andersen
JMJohan Meyers
Johan Meyers
Wind farm flow control (WFFC) is a topic of interest at several research institutes, industry and certification agencies world-wide. For reliable performance assessment of the technology, the efficiency and the capability of the models applied to WFFC should be carefully evaluated. To address that, FarmConners consortium has launched a common benchmark for code comparison under controlled operation to demonstrate its potential benefits such as increased power production. The benchmark builds on available data sets from previous field campaigns, wind tunnel experiments and high-fidelity simulations. Within that database, 4 blind tests are defined and 13 participants in total have submitted results for the analysis of single and multiple wake under WFFC. Some participants took part in several blind tests and some participants have implemented several models. The observations and/or the model outcomes are evaluated via direct power comparisons at the upstream and downstream turbine(s), as well as the power gain at the wind farm level under wake steering control strategy. Additionally, wake loss reduction is also analysed to support the power performance comparison, where relevant. Majority of the participating models show good agreement with the observations or the reference high-fidelity simulations, especially for lower degrees of upstream misalignment and narrow wake sector. However, the benchmark clearly highlights the importance of the calibration procedure for control-oriented models. The potential effects of limited controlled operation data in calibration is particularly visible via frequent model mismatch for highly deflected wakes, as well as the power loss at the controlled turbine(s). In addition to the flow modelling, sensitivity of the predicted WFFC benefits to the turbine representation and the implementation of the controller is also underlined. FarmConners benchmark is the first of its kind to bring a wide variety of data sets, control settings and model complexities for the (initial) assessment of farm flow control benefits. It forms an important basis for more detailed benchmarks in the future with extended control objectives to assess the true value of WFFC.

4 September 2026 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
TDThomas Duc
Thomas Duc
AFArthur Finez
Arthur Finez
Wake steering is a wind farm flow control (WFFC) strategy that involves intentionally misaligning the most upstream wind turbines to deviate their wakes away from the downstream wind turbines. This study investigates the acoustic implications of such a strategy. A novel acoustic setup is implemented, involving 24 ground-based sound level meters arranged on a circle around an industrial 2.2 MW wind turbine, positioned at tip-height distance. This configuration enables a fine angular resolution of 15 ° . Incoming wind conditions are monitored using both a nacelle-mounted and a ground-based lidar. A test protocol closely aligned with IEC 61400-11-1 is followed to characterize the turbine's noise emissions under various yaw misalignment settings, ranging from −20 to +20 ° across a broad spectrum of flow conditions. A dedicated data cleaning and analysis procedure is developed to derive ground-level turbine noise directivity patterns. In the absence of yaw misalignment, the directivity patterns exhibit a typical two-lobe structure. However, slight but statistically significant asymmetries are also observed: the downstroke side is on average 0.6 dB(A) louder than the upstroke side, and the downwind side is 0.4 dB(A) louder than the upwind side. These specificities are not captured by most of the analytical models used in the field. When yaw misalignment is applied, a modest increase of approximately 0.6 dB(A) is observed in the estimated overall sound power level. The results from this innovative experiment confirm the fact that operators must consider metrics other than just power production when implementing WFFC in their projects and that more advanced noise models are required for the development of a framework allowing multi-objective WFFC.

27 August 2026 in Wind Energy Science
Verified
Journal Article
Open access
PDF file
VPVasilis Pettas
Vasilis Pettas
TGTuhfe Göçmen
Tuhfe Göçmen
TDThomas Duc
Thomas Duc
AVAndreas Vad
Andreas Vad
AVAntonina Vukobrat
Antonina Vukobrat
As wind energy deployment expands, bat protection curtailment is increasingly required for ecological and regulatory reasons. Operators typically implement static, also called “blanket”, schedules based on environmental thresholds for predefined periods, while dynamic approaches based on real-time sensing have emerged as an alternative that can reduce unnecessary curtailment. To date, these strategies have been primarily evaluated using production-based metrics, although frequent curtailment-induced start-ups and shutdowns may affect structural loading and long-term fatigue accumulation. This study proposes an evaluation methodology to quantify impacts on both energy production and structural fatigue accumulation under different bat protection operational strategies. The methodology combines long-term environmental and bat activity data with wind-farm flow modeling, mode-dependent surrogate models to represent aeroelastic fatigue response in normal and curtailment-related operating states, and consistent aggregation of energy and fatigue metrics over long-time horizons. The approach is demonstrated in a case study of an onshore wind farm in France by comparing representative static and dynamic bat protection strategies with a baseline in which no bat protection strategy is implemented. The results show that energy losses are lower for the evaluated dynamic strategies compared to all considered static schedules. Cumulative fatigue impacts are channel dependent and are small for most responses and bat protection strategies. However, some loads showed sensitivity to curtailment, indicating that bat activity frequency and its combination with the local climate can lead to increased fatigue loading. The operational, energy, and fatigue cumulative impacts are analyzed, along with the effects of interannual variability, and the main drivers and sensitivities are identified. Based on these, implications for decision-making when selecting an operational strategy are discussed, and the need for the site-specific evaluation of both energy and fatigue is highlighted. Moreover, key assumptions are explained and research gaps are identified, especially how fatigue contributions from transient events should be modeled and accounted for in long-term evaluations. Finally, based on the findings, pathways to optimize bat protection strategies are suggested, aiming to achieve the targeted bat protection levels while minimizing energy losses and supporting asset reliability.