The blades in a wind turbine are currently manufactured with flexible and light materials, which make them more susceptible to the effects of vibrations when the wind speed is high enough, causing fatigue damage, affecting the functionality of its structure and aerodynamic efficiency. This work presents a comparison of the modal vibration parameters, applied to a cantilever beam, determined with two experimental methods—the use of accelerometers and a proposed optical non-contact method—based on the principle of laser triangulation and photogrammetry techniques. This technique uses the geometric symmetry of the equidistant displacements along the z axis of the beam to obtain the amplitude data. Parameters such as natural frequency and modal form are obtained by fitting the data to a nonlinear equation with a solution which is an exponential/harmonic equation. Also, analytically, these parameters are determined, and a comparison is made between the experimental methods. The result shows that the relative error of the first-order natural vibration frequency is below 1%. The proposed method is simple, efficient, reliable, and it is also a method that has not been applied to the test of wind turbine blades, so its implementation as this type of wind turbine component is an area of opportunity for the validation of modal vibration parameters in the wind industry. An analysis of results is presented showing benefits of the proposed method and its limitations.
31 January 2014 in Journal of the Optical Society of America A
The aim of this work is threefold: first we obtain analytical expressions for the wavefront train and the caustic associated with the refraction of a plane wavefront by an axicon lens, second we describe the structure of the ronchigram when the ronchiruling is placed at the flat surface of the axicon and the screen is placed at different relative positions to the caustic region, and third we describe in detail the structure of the null ronchigrating for this system; that is, we obtain the grating such that when it is placed at the flat surface of the axicon its associated pattern, at a given plane perpendicular to the optical axis, is a set of parallel fringes. We find that the caustic has only one branch, which is a segment of a line along the optical axis; the ronchigram exhibits self-intersecting fringes when the screen is placed at the caustic region, and the null ronchigrating exhibits closed loop rulings if we want to obtain its associated pattern at the caustic region.
The development of an optical contact instrument for measuring the geometric shape of aerodynamic profiles on blades of small power wind turbines is presented. The instrument uses the triangulation principle, where a structured line laser pattern is projected onto the surface of one of the faces of the blade under test, a camera captures the image of the line and is processed to interpret the distorted form of the projected line. A linear sweep of the instrument makes it possible to measure the profile in another section of the blade. Comparison and evaluation results of two symmetric profiles of the NACA 0012 family are presented, one manufactured in a 3D printer and the other one is a metal profile AF104 of a subsonic wind tunnel. Additionally, three sections of a blade with profile FX 63‐137 of a 1.5 kW wind turbine were evaluated. An aerodynamic analysis shows a reduction in the lift coefficient and in the efficiency of the aerodynamic profile, as well as an increase in the drag coefficient. The sensitivity of the instrument is 0.1 mm on the Z‐axis.
We study the formation of caustic surfaces produced by conic lenses, considering a plane wavefront propagating parallel to the optical axis. The shape of the caustic can be modified by changing the parameters of the lens in such a way that if we are able to vanish the caustic, the optical system produces the sharpest diffraction-limited images. Alternatively, caustic surfaces with a large area can be applied to the design of non-imaging optical systems, with potential applications such as diffusers of light for illumination or solar concentrators. Here, we provide analytic equations for the conic constants, principal surfaces, and caustic surfaces, and also approximations at the third and fifth orders formed by conic lenses, in order to reduce the spherical aberration at these orders.
10 January 2013 in Journal of the Optical Society of America A
The aim of the present work is twofold: first we obtain analytical expressions for both the wavefronts and the caustic associated with the light rays reflected by a spherical mirror after being emitted by a point light source located at an arbitrary position in free space, and second, we describe, in detail, the structure of the ronchigrams when the grating or Ronchi ruling is placed at different relative positions to the caustic region and the point light source is located on and off the optical axis. We find that, in general, the caustic has two branches: one is a segment of a line, and the other is a two-dimensional surface. The wavefronts, at the caustic region, have self intersections and singularities. The ronchigrams exhibit closed-loop fringes when the grating is placed at the caustic region.
We present a null-screen design for testing the shape quality of the reflecting surface of a parabolic trough solar collector (PTSC). This technique is inexpensive, the whole surface is tested at once, and it is easy to implement. For this, we propose the design of a flat null-screen perpendicular to the optical axis of the PTSC in such a way that it allows testing of the full aperture; we compute the caustic associated with the reflected light rays on the desired surface and analyze the parameters that determine the null-screen dimensions. Additionally, we perform a numerical simulation to analyze the accuracy of the method by introducing random displacement errors into the measured data. Accuracies were found to evaluate the quality of surfaces with this method. The errors in the determination of the coordinates of the centroids of the reflected images must be measured with an accuracy , and the errors in the coordinates of the spots of the null-screen must be .