Qiang Du

Qiang Du

Auto-generated profile, based on publicly available information

Qiang Du

School of Electrical Engineering, Shenyang University of Technology, Shenyang, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2019 in IEEE Access
Verified
Journal Article
Open access
JLJinghui Li
Jinghui Li
LKLi Ke
Li Ke
QDQiang Du
Qiang Du
XDXiaodi Ding
Xiaodi Ding
XCXiangmin Chen
Xiangmin Chen
DWDanni Wang
Danni Wang
By classifying the heart sound signals, it can provide very favorable clinical information to the diagnosis of cardiovascular diseases. According to the characteristics of heart sound signals which are complex and difficult to classify and recognize, a new method of feature extraction and classification about heart sound signal is proposed by a combination of wavelet scattering transform and twin support vector machine in this paper. The method is as follows: The heart sound signal data set is firstly divided into two parts, one as a training set and the other as a testing set. Then the wavelet scattering transform is applied to the heart sound signals in the training set and the testing set. The scattering transform is a new timefrequency analysis method. It overcomes the shortcomings of the traditional wavelet transform which has the time-shift changes. It has the advantages of translation invariance and elastic deformation stability. Thus obtain the scattering feature matrix of the heart sound signal. Due to the large dimension of scattering feature matrix, this paper uses multidimensional scaling (MDS) method to reduce the dimension. This method is compared with the classical dimension reduction method—principal component analysis (PCA). Finally, the dimensionality-reduced feature matrix is input into the twin support vector machine (TWSVM) for training. After training the classifier to get the optimal parameters, the dimensionality-reduced scattering feature matrix of the testing signal is input into the classifier for testing. Experimental results show that the classification accuracy of the proposed method can reach 98% or more, and the running time is greatly reduced compared with support vector machine (SVM).

6 May 2019 in Entropy
Verified
Journal Article
Open access
PDF file
JLJinghui Li
Jinghui Li
LKLi Ke
Li Ke
QDQiang Du
Qiang Du
Heart is an important organ of human beings. As more and more heart diseases are caused by people’s living pressure or habits, the diagnosis and treatment of heart diseases also require technical improvement. In order to assist the heart diseases diagnosis, the heart sound signal is used to carry a large amount of cardiac state information, so that the heart sound signal processing can achieve the purpose of heart diseases diagnosis and treatment. In order to quickly and accurately judge the heart sound signal, the classification method based on Wavelet Fractal and twin support vector machine (TWSVM) is proposed in this paper. Firstly, the original heart sound signal is decomposed by wavelet transform, and the wavelet decomposition coefficients of the signal are extracted. Then the two-norm eigenvectors of the heart sound signal are obtained by solving the two-norm values of the decomposition coefficients. In order to express the feature information more abundantly, the energy entropy of the decomposed wavelet coefficients is calculated, and then the energy entropy characteristics of the signal are obtained. In addition, based on the fractal dimension, the complexity of the signal is quantitatively described. The box dimension of the heart sound signal is solved by the binary box dimension method. So its fractal dimension characteristics can be obtained. The above eigenvectors are synthesized as the eigenvectors of the heart sound signal. Finally, the twin support vector machine (TWSVM) is applied to classify the heart sound signals. The proposed algorithm is verified on the PhysioNet/CinC Challenge 2016 heart sound database. The experimental results show that this proposed algorithm based on twin support vector machine (TWSVM) is superior to the algorithm based on support vector machine (SVM) in classification accuracy and speed. The proposed algorithm achieves the best results with classification accuracy 90.4%, sensitivity 94.6%, specificity 85.5% and F1 Score 95.2%.

19 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JLJinghui Li
Jinghui Li
LKLi Ke
Li Ke
QDQiang Du
Qiang Du
XDXiaodi Ding
Xiaodi Ding
XCXiangmin Chen
Xiangmin Chen
Because a cardiac function signal cannot reflect cardiac health in all directions, we propose a classification method using ECG and PCG signals based on BiLSTM-GoogLeNet-DS. The electrocardiogram (ECG) and phonocardiogram (PCG) signals used as research objects were collected synchronously. Firstly, the obtained ECG and PCG signals were filtered, and then the ECG and PCG signals were fused and classified by using a bi-directional long short-term memory network (BiLSTM). After that, the time-frequency processing was performed on the filtered ECG and PCG signals to obtain the time-frequency diagram of each signal; the one-dimensional signal was changed into a two-dimensional image signal, and the size of each image signal was adjusted to input the improved GoogLeNet network for classification. Then we obtained the two-channel classification results. The three-channel classification results, combined with the classification results of the above BiLSTM network, were finally obtained. The classification results of these three channels were used to make a decision via the fusion strategy of the improved D-S theory. Finally, we obtained the classification results. Taking 70% of the signals in the database as training data and 30% as test data, the obtained classification accuracy was 96.13%, the sensitivity was 98.48%, the specificity was 90.8%, and the F1 score was 97.24%. From the experimental results, the method proposed in this paper obtained high classification accuracy, and the classification effect was better than a cardiac function signal, which makes up for the low accuracy of the cardiac function signal for judging cardiac disease.

21 June 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
QZQiaoli Zhou
Qiaoli Zhou
CSChi Shi
Chi Shi
QDQiang Du
Qiang Du
LKLi Ke
Li Ke

2 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JCjia chen
jia chen
LKLi Ke
Li Ke
QDQiang Du
Qiang Du
YZYawen Zheng
Yawen Zheng
YLYanan Liu
Yanan Liu
Background: Cerebral blood flow (CBF) auto-regulation function is essential for evaluating CBF status. This article provides an evaluation method of CBF using bioimpedance. Method: A mathematical model of cerebral vascular compliance is established to analyze the effect of autoregulation ability changes on the impedance of CBF. The synchronization signals of impedance and blood pressure are measured, and the peak phase shift is extracted to evaluate the cerebral blood autoregulation function. Results: The experiment results show that the peak phase shift can express the cerebral autoregulation change process. The frontal and occipital region’s peak phase shift changes are 10.32%–37.6% and 11.18%–36.86%, respectively. Significant: The proposed approach could build the relationship between CBF autoregulation and impedance, and this method is noninvasive, continuous, and easy to execute. This study provides a basis for the health assessment of the CBF system using bioimpedance.

23 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTie Liu
Tie Liu
Dianchun BaiDianchun Bai
Dianchun Bai
LMLe Ma
Le Ma
QDQiang Du
Qiang Du
HYHiroshi Yokoi
Hiroshi Yokoi
Background: Surface electromyography-based gesture recognition and prosthetic hand control using deep learning have become increasingly significant in the field of human-computer interaction. Objective: This study aims to enhance the control of prosthetic hands driven by complex gestures, addressing the challenge of low-resolution gesture differentiation caused by the coupling and superposition of surface electromyography signals in deep learning models. Method: We propose a deep learning-based framework for the recognition of complex surface electromyography signals, utilizing a multi-pathway approach to acquire raw surface electromyography signals, process them in the time-frequency domain, and extract features using multi-scale convolutional networks. The processed surface electromyography features are then analyzed in parallel to enhance accuracy. Results: This method effectively processes multiple signals concurrently and extracts diverse feature sets. By collecting data from six channels, it achieves an 88.56% recognition rate for 16 complex hand gestures, enabling control of 10 distinct prosthetic hand movements. Conclusion: By leveraging multi-dimensional continuous surface electromyography images, we have developed a feature model that resolves the issues of signal coupling and superposition in multi-channel surface electromyography data, allowing for precise control of prosthetic hand movements.