Stephan Bauer

Stephan Bauer

Auto-generated profile, based on publicly available information

Stephan Bauer

Quantum Metrology, Physikalisch - Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Braunschweig, 38116, GERMANY

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2017 in Metrologia
Verified
Journal Article
Closed access
PDF file
SBS Bauer
S Bauer
RBR Behr
R Behr
THT Hagen
T Hagen
OKO Kieler
O Kieler
JLJ Lee
J Lee
JSJ Schurr
J Schurr
In this paper the realization of a two-terminal-pair impedance bridge based on pulse-driven Josephson arrays will be presented. This bridge was used to link a 10 nF capacitance standard to the quantized Hall resistance at 1233 Hz. With pulse-driven Josephson arrays the setup for a quadrature bridge can be reduced dramatically. For the combination of the AC quantum Hall resistance and a 10 nF capacitance standard, most of the uncertainties caused by contact resistances in a two-terminal-pair definition were circumvented by a triple-series connection of the AC quantum Hall resistance. The capacitance value obtained by the new Josephson impedance bridge was compared to the results from a transformer-based ratio bridge and agrees within 1.3 parts in 10 8 . Sources of systematic uncertainties were investigated and the combined relative uncertainty of the bridge was determined to be less than 1 × 10 − 8 ( k = 1) and 13.9 nF F −1 ( k = 1) for the link of the 10 nF capacitance standard.

3 June 2021 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
MKMattias Kruskopf
Mattias Kruskopf
SBStephan Bauer
Stephan Bauer
YPYaowaret Pimsut
Yaowaret Pimsut
ACAtasi Chatterjee
Atasi Chatterjee
DPDinesh K. Patel
Dinesh K. Patel
JSJurgen Schurr
Jurgen Schurr
A new type of graphene-based quantum Hall standards is tested for electrical quantum metrology applications at alternating current (ac) and direct current (dc). The devices are functionalized with Cr(CO) 3 to control the charge carrier density and have branched Hall contacts based on NbTiN superconducting material. The work is an in-depth study about the characteristic capacitances and related losses in the ac regime of the devices and about their performance during precision resistance measurements at dc and ac.

21 December 2022 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
SBStephan Bauer
Stephan Bauer
RBRalf Behr
Ralf Behr
JHJonas Herick
Jonas Herick
OKOliver F Kieler
Oliver F Kieler
MKMarco Kraus
Marco Kraus
LPLuis Palafox
Luis Palafox
About 60 years after the discovery of the Josephson effect, electrical DC voltage calibrations are routinely performed worldwide—mostly using automated Josephson voltage standards (JVSs). Nevertheless, the field of electrical quantum voltage metrology is still propagating towards AC applications. In the past 10 years the fabrication of highly integrated arrays containing more than 50 000 or even 300 000 junctions has achieved a very robust level providing highly functional devices. Such reliable Josephson arrays are the basis for many novel applications mainly focussing on precision AC measurements for signal frequencies up to 500 kHz. Two versions of quantum AC standards are being employed. Programmable JVS, based on series arrays divided into subarrays, reach amplitudes up to 20 V and usually are used as quantum voltage reference in measurement systems. Pulse driven arrays reach amplitudes up to 1 V or even 4 V and are typically used as Josephson arbitrary waveform synthesizers. This paper summarizes the principal contributions from Physikalisch-Technische Bundesanstalt to the present state of JVS with particular focus on developments for precision metrological applications and our proof-of-concept demonstrations.

19 February 2024 in Metrologia
Verified
Journal Article
Open access
YPYaowaret Pimsut
Yaowaret Pimsut
SBStephan Bauer
Stephan Bauer
MKMarco Kraus
Marco Kraus
RBRalf Behr
Ralf Behr
MKMattias Kruskopf
Mattias Kruskopf
LPLuis Palafox
Luis Palafox
The four-terminal-pair impedance bridge using pulse-driven Josephson voltage standards at PTB has been fully automated. The same bridge configuration was employed to determine R:R and C:C ratios over the frequency range between 53 Hz to 50 kHz. Only minor changes are needed to cover this large frequency range: amplifiers to increase the sensitivity of the current detections for low frequencies and signal generators with higher resolution at high frequencies to reach 50 kHz. Furthermore, the bridge can be operated for quadrature R:(1/ωC) measurements. The combined standard uncertainties (k = 1) for the new bridge were evaluated for all operating frequencies. They reach 2 nF F−1 and 4 nΩ Ω−1 at 1233.15 Hz. At this frequency, the 10 nF:10 nF ratio matched the ratio of PTB’s bridge employing inductive voltage dividers within 1 nF F−1 ± 3 nF F−1 (k = 1). Over 45 days, the 10 nF:10 nF ratio deviated less than −2 nF F−1 ± 3 nF F−1 (k = 1). The 12.9 kΩ:10 kΩ ratio at 53 Hz differed −2 nΩ Ω−1 ± 5 nΩ Ω−1 (k = 1) from the DC ratio measured by the PTB’s cryogenic current comparator bridge. Using a 12.9 kΩ resistance standard and a graphene AC quantum Hall resistance, the 10 nF:10 nF ratios derived from quadrature measurements agreed with the PTB’s inductive voltage divider bridge better than 9 nF F−1 ± 13 nF F−1 (k = 1).

31 March 2021 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
SBStephan Bauer
Stephan Bauer
RBRalf Behr
Ralf Behr
RERandolph E. Elmquist
Randolph E. Elmquist
MGM Götz
M Götz
JHJonas Herick
Jonas Herick
MGMartin Goetz
Martin Goetz
This paper introduces a four-terminal-pair impedance bridge based on pulse-driven Josephson junctions arrays which is designed to link any kind of impedance to the quantized Hall resistance. The unique features of the quantized Hall resistance in a multiple series connection allows to dispense a combining network and leads to a compact and simple design of the whole setup. Moreover, the low noise of a quantized Hall resistance reduces the measurement time compared to resistance standards at room temperature which is essential for the characterization of quantum Hall devices in the AC regime. A first measurement campaign confirmed the expected low noise of 1.82 n V / H z for a link to a 10 nF capacitance standard. The repeatability of the bridge was found to be few parts in 108. Capacitance and resistance standards were measured at 1233.15 Hz against graphene based quantum Hall resistance devices.

13 June 2019 in Metrologia
Verified
Journal Article
Open access
PDF file
OROliver Rest
Oliver Rest
DWDaniel Winzen
Daniel Winzen
SBStephan Bauer
Stephan Bauer
RBRoland Berendes
Roland Berendes
JMJohann Meisner
Johann Meisner
TTThomas Thuemmler
Thomas Thuemmler
The most common method to measure direct current high voltage (HV) down to the ppm-level is to use resistive high-voltage dividers. Such devices scale the HV into a range where it can be compared with precision digital voltmeters to reference voltages sources, which can be traced back to Josephson voltage standards. So far the calibration of the scale factors of HV dividers for voltages above 1~kV could only be done at metrology institutes and sometimes involves round-robin tests among several institutions to get reliable results. Here we present a novel absolute calibration method based on the measurement of a differential scale factor, which can be performed with commercial equipment and outside metrology institutes. We demonstrate that reproducible measurements up to 35~kV can be performed with relative uncertainties below $1\cdot10^{-6}$. This method is not restricted to metrology institutes and offers the possibility to determine the linearity of high-voltage dividers for a wide range of applications.