1 February 2023 in Acta Materialia
23 March 2024 in Acta Materialia
25 April 2024 in Advanced Engineering Materials
Herein, the effect of heat treatment on the characteristics and properties of cold spray additive manufactured 316L stainless steel employing traditional and a new metal knitting strategy is investigated. 316L feedstock powder characteristics, the geometry of the bulk, microstructure, porosity, microhardness, mechanical isotropy, and residual stress are analyzed in both strategies in as‐sprayed and heat‐treated conditions. Results show that the traditional deposition strategy produced higher mechanical resistance, whereas metal knitting presents a better part geometry accuracy. The heat treatment significantly improves the material strength and the quality of the parts by recovery and recrystallization phenomena. The same microhardness and planar isotropy are achieved after heat treatment of samples produced by both strategies. A discussion about the mechanisms, microstructural, and residual stress evolution is presented.
1 January 2017 in European Journal of Dentistry
MNMurilo Alves Teixeira Neto
Murilo Alves Teixeira Neto
LHLuis Flávio Gaspar Herculano
Luis Flávio Gaspar Herculano
+1
Objective: This study sought to assess the influence of cervical preflaring and reuse after resterilization, on fracture strength and plastic deformation and/or surface cracking in reciprocating nickel–titanium [NiTi] endodontic instruments after root canal instrumentation of extracted human teeth. Materials and Methods: Forty engine-driven reciprocating NiTi instruments (20 Reciproc® [RC], VDW; 20 WaveOne® [WO], Dentsply) were used in root canal instrumentation of extracted human molars. A total of 485 human upper molars with similar anatomical features were selected and randomly distributed across four groups according to the instrumentation procedures performed (G1 and G3: RC; G2 and G4: WO). Reciprocating instruments were used as per manufacturer instructions. In groups G3 and G4, cervical preflaring was performed prior to instrumentation. After each use of each instrument, sterilization was repeated and scanning electron microscope (SEM) images were obtained to check for plastic deformations and/or cracks on instrument surfaces. Each instrument was used repeatedly until fracture occurred. Results: Regardless of flaring, RC files exhibited greater fracture strength than WO instruments (P
18 October 2023 in Metallurgical and Materials Transactions A
20 November 2025 in Acta Materialia