José Manuel González-LaFuente

José Manuel González-LaFuente

Auto-generated profile, based on publicly available information

José Manuel González-LaFuente

COGERSA, S.A.U. La Zoreda, Serín, 33697 Gijón, Spain

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2024 in Reaction Chemistry & Engineering
Verified
Journal Article
Open access
PDF file
MBMatthijs Justin Boel
Matthijs Justin Boel
HWHongqi Wang
Hongqi Wang
AFAhmad AL Farra
Ahmad AL Farra
LMLaura Megido
Laura Megido
JGJosé Manuel González-LaFuente
José Manuel González-LaFuente
NSN. Raveendran Shiju
N. Raveendran Shiju
Plastic waste is a major global issue and hydrothermal liquefaction is a promising technique for the chemical recycling of waste plastics. This review summarises the effect of reaction conditions on the liquefaction efficiency.

1 January 1998 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JLJ. M. González Lafuente
J. M. González Lafuente
MDM. Dlaska
M. Dlaska
MSM. L.FErnández Sánchez
M. L.FErnández Sánchez
ASA. Sanz-Medel
A. Sanz-Medel
A vesicle mediated high performance liquid chromatographic (HPLC)–microwave digestion (MW)–hydride generation (HG) system coupled on-line with atomic absorption spectrometry (AAS) and inductively coupled plasma mass spectrometry (ICP-MS) has been assessed for selenium species separation and detection. Selenocystine, selenomethionine, selenoethionine, selenourea, SeIV and SeVI are separated by vesicle mediated chromatography prior to on-line selenocompounds microwave digestion with a KBrO3–HBr mixture to generate SeIV continuously, which is finally transformed into SeH2, in a continuous manner with a merging flow of sodium tetrahydroborate(III). Analytical characteristics of this coupling are compared with those obtained coupling HPLC–ICP-MS via conventional nebulisation. Detection limits (DLs) obtained for selenocystine, selenomethionine, selenoethionine, selenite and selenate in spiked human urine, when ICP-MS was used as detector, ranged between 1.0 and 5.3 µg l–1 (51–267 pg), while precision ranged between±3.4 and±8.4%. This continuous system, vesicle mediated HPLC–MW–HG–atomic detection, allows the separation and detection of selenocystine, selenourea, selenomethionine, selenoethionine, selenite and selenate in human urine. The analytical versatility of such coupling (with ICP-MS as the atomic detector) allows basal selenium speciation in urine. Three different normally occurring selenium species in human urine, simply diluted (1+1), have been found. The relative sophistication of the vesicle mediated–HPLC–MW–HG–ICP-MS interface, versus HPLC–ICP-MS via conventional nebulisation, can be justified because of its considerably higher sensitivity for most of the selenocompounds assayed, lower matrix interferences and the possibility of simultaneous interference free 77Se and 78Se monitoring.

1 January 2016 in Waste Management
Verified
Journal Article
Open access
DGDiego Garcés
Diego Garcés
Eva DiazEva Diaz
Eva Diaz
HSHerminio Sastre
Herminio Sastre
Salvador OrdoñezSalvador Ordoñez
Salvador Ordoñez
JGJosé Manuel González-LaFuente
José Manuel González-LaFuente
Solid recovered fuels constitute a valuable alternative for the management of those non-hazardous waste fractions that cannot be recycled. The main purpose of this research is to assess the suitability of three different wastes from the landfill of the local waste management company (COGERSA), to be used as solid recovered fuels in a cement kiln near their facilities. The wastes analyzed were: End of life vehicles waste, packaging and bulky wastes. The study was carried out in two different periods of the year: November 2013 and April 2014. In order to characterize and classify these wastes as solid recovered fuels, they were separated into homogeneous fractions in order to determine different element components, such as plastics, cellulosic materials, packagings or textile compounds, and the elemental analysis (including chlorine content), heavy metal content and the heating value of each fraction were determined. The lower heating value of the waste fractions on wet basis varies between 10 MJ kg(-1) and 42 MJ kg(-1). One of the packaging wastes presents a very high chlorine content (6.3 wt.%) due to the presence of polyvinylchloride from pipe fragments, being the other wastes below the established limits. Most of the wastes analyzed meet the heavy metals restrictions, except the fine fraction of the end of life vehicles waste. In addition, none of the wastes exceed the mercury limit content, which is one of the parameters considered for the solid recovered fuels classification. A comparison among the experimental higher heating values and empirical models that predict the heating value from the elemental analysis data was carried out. Finally, from the three wastes measured, the fine fraction of the end of life vehicles waste was discarded for its use as solid recovered fuels due to the lower heating value and its high heavy metals content. From the point of view of the heating value, the end of life vehicles waste was the most suitable residue with a lower heating value of 35.89 MJ kg(-1), followed by the packaging waste and the bulky waste, respectively. When mixing the wastes studied a global waste was obtained, whose classification as solid recovered fuels was NCV 1 Cl 3 Hg 3. From the empirical models used for calculating higher heating value from elemental content, Scheurer-Kestner was the model that best fit the experimental data corresponding to the wastes collected in November 2013, whereas Chang equation was the most approximate to the experimental heating values for April 2014 fractions. This difference is due to higher chlorine content of the second batch of wastes, since Chang equation is the only one that incorporates the chlorine content.

1 January 1996 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JLJ. M. González Lafuente
J. M. González Lafuente
MSM. L. Fernández Sánchez
M. L. Fernández Sánchez
ASA. Sanz-Medel
A. Sanz-Medel
A high-performance liquid chromatographic–microwave digestion–hydride generation system coupled on-line with three atomic detectors (atomic absorption, inductively coupled plasma atomic emission and inductively coupled plasma mass spectrometry) has been developed and investigated for selenium species separation and determination. Total inorganic selenium, selenomethionine and selenoethionine are separated by reversed-phase chromatography prior to on-line microwave digestion of selenocompounds with a KBrO3–HBr mixture to form continuously SeIV, which is finally transformed into H2Se, also in a continuous manner, with a merging flow of sodium borohydride. Detection limits obtained for each Se species in water and urine using the three atomic detectors have been worked out and compared (i.e., for SeIV DLs were 6.8 µg l–1 by AAS, 30 µg l–1 by ICP-AES and 0.16 µg l–1 by ICP-MS). The integrated flow system, HPLC–MW digestion–HG-atomic detection, proposed here allows, in a single injection, reliable speciation in urine of the selenoaminoacids tested versus total inorganic selenium. Further speciation of the overlapped inorganic SeIV and SeVI peaks is accomplished by a second injection of the urine sample to determine only SeIV by avoiding microwave heating. Results on Se speciation in human urine have shown that more speciation information of the actual species, perhaps unknown, present in real samples could be gathered by resorting to the use of two, or more, atomic detectors coupled to the same separation scheme.

1 December 2018 in Journal of Bioscience and Bioengineering
Verified
Journal Article
Open access
ADAna Isabel Díaz
Ana Isabel Díaz
Paula OulegoPaula Oulego
Paula Oulego
SCSergio Collado
Sergio Collado
APAdriana Laca Perez
Adriana Laca Perez
JGJosé Manuel González
José Manuel González
MDMario Díaz
Mario Díaz
Sewage sludge can be treated by anaerobic processes that frequently are followed by physical separation processes. In this work, a high-throughput sequencing technology, based on variation in the bacterial 16S rRNA gene, has been used to characterise the bacterial populations present in samples taken from different points of an industrial anaerobic digestion process fed with sewage sludge. Relative abundances of phyla and classes throughout the biological process and the subsequent separation steps were determined. Results revealed that the Bacteroidetes, Firmicutes and Proteobacteria phyla were the most representative. However, significant changes in relative abundance were detected along treatments, showing the influence of operational parameters on the distribution of microorganisms throughout the process. After anaerobic digestion, phylum Firmicutes doubled its relative abundance, which seems to indicate that the anaerobic conditions and the nutrients favoured its growth, in contrast to other phyla that almost disappeared. After centrifugation, Proteobacteria went preferentially to the solid phase, in contrast to Firmicutes which was the dominant phylum in the liquid phase. After decanting the liquid phase during 45 h, an important growth of Proteobacteria, Spirochaetes and Tenericutes was detected. At class level, only significantly changes were observed for Proteobacteria classes being α-proteobacteria dominant in the digestate, while γ-proteobacteria was the majority since this point to the final steps. To know the changes on the kind and abundance of microbial populations throughout the anaerobic and separation processes is very important to understand how the facilities design and operation conditions can influence over the efficiencies of next biological treatments.

1 December 1996 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
JLJ.Manuel González LaFuente
J.Manuel González LaFuente
MSM.LUisa Fernández Sánchez
M.LUisa Fernández Sánchez
JMJ.MAnuel Marchante-Gayón
J.MAnuel Marchante-Gayón
JUJ.ENrique Sánchez Uria
J.ENrique Sánchez Uria
ASAlfredo Sanz-Medel
Alfredo Sanz-Medel