Eugenio Anselmino

Eugenio Anselmino

Auto-generated profile, based on publicly available information

Eugenio Anselmino

Department of Excellence in Robotics and AI, Biorobotics Institute, Scuola Superiore SantAnna, Pisa, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Small Methods
Verified
Journal Article
Closed access
RGRaghav Garg
Raghav Garg
NDNicolette Driscoll
Nicolette Driscoll
SSSneha Shankar
Sneha Shankar
THTodd Hullfish
Todd Hullfish
EAEugenio Anselmino
Eugenio Anselmino
FVFlavia Vitale
Flavia Vitale

20 December 2023 in Science Robotics
Verified
Journal Article
Closed access
GDGiulia Dominijanni
Giulia Dominijanni
DPDaniel Leal Pinheiro
Daniel Leal Pinheiro
LPLeonardo Pollina
Leonardo Pollina
BOBastien Orset
Bastien Orset
MGMartina Gini
Martina Gini
SMSilvestro Micera
Silvestro Micera
Extra robotic arms (XRAs) are gaining interest in neuroscience and robotics, offering potential tools for daily activities. However, this compelling opportunity poses new challenges for sensorimotor control strategies and human-machine interfaces (HMIs). A key unsolved challenge is allowing users to proficiently control XRAs without hindering their existing functions. To address this, we propose a pipeline to identify suitable HMIs given a defined task to accomplish with the XRA. Following such a scheme, we assessed a multimodal motor HMI based on gaze detection and diaphragmatic respiration in a purposely designed modular neurorobotic platform integrating virtual reality and a bilateral upper limb exoskeleton. Our results show that the proposed HMI does not interfere with speaking or visual exploration and that it can be used to control an extra virtual arm independently from the biological ones or in coordination with them. Participants showed significant improvements in performance with daily training and retention of learning, with no further improvements when artificial haptic feedback was provided. As a final proof of concept, naïve and experienced participants used a simplified version of the HMI to control a wearable XRA. Our analysis indicates how the presented HMI can be effectively used to control XRAs. The observation that experienced users achieved a success rate 22.2% higher than that of naïve users, combined with the result that naïve users showed average success rates of 74% when they first engaged with the system, endorses the viability of both the virtual reality–based testing and training and the proposed pipeline.

28 August 2023 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Open access
FBF. Barberi
F. Barberi
EAE. Anselmino
E. Anselmino
AMAlberto Mazzoni
Alberto Mazzoni
MGM. Goldfarb
M. Goldfarb
SMSilvestro Micera
Silvestro Micera
The last few years witnessed radical improvements in lower-limb prostheses. Researchers have presented innovative solutions to overcome the limits of the first generation of prostheses, refining specific aspects which could be implemented in future prostheses designs. Each aspect of lower-limb prostheses has been upgraded, but despite these advances, a number of deficiencies remain and the most capable limb prostheses fall far short of the capabilities of the healthy limb. This paper describes the current state of prosthesis technology; identifies a number of deficiencies across the spectrum of lower limb prosthetic components with respect to users' needs; and discusses research opportunities in design and control that would substantially improve functionality concerning each deficiency. In doing so, the authors present a roadmap of patients related issues that should be addressed in order to fulfill the vision of a next-generation, neurally-integrated, highly-functional lower limb prosthesis.

1 April 2023 in Journal of Neural Engineering
Verified
Journal Article
Closed access
FBFederica Barberi
Federica Barberi
FIFrancesco Iberite
Francesco Iberite
EAEugenio Anselmino
Eugenio Anselmino
PRPericle Randi
Pericle Randi
RSRinaldo Sacchetti
Rinaldo Sacchetti
SMSilvestro Micera
Silvestro Micera
Objective. Powered lower-limb prostheses relying on decoding motor intentions from non-invasive sensors, like electromyographic (EMG) signals, can significantly improve the quality of life of amputee subjects. However, the optimal combination of high decoding performance and minimal set-up burden is yet to be determined. Here we propose an efficient decoding approach obtaining high decoding performance by observing only a fraction of the gait duration with a limited number of recording sites. Approach. Thirteen transfemoral amputee subjects performed five motor tasks while recording EMG signals from four muscles and inertial signals from the prosthesis. A support-vector-machine-based algorithm decoded the gait modality selected by the patient from a finite set. We investigated the trade-off between the robustness of the classifier’s accuracy and the minimization of (i) the duration of the observation window, (ii) the number of EMG recording sites, (iii) the computational load of the procedure, measured the complexity of the algorithm. Main results. When including pre-foot-strike data in the decoding, the combination of three EMG recording sites and the inertial signals led to correct rates above 94% at the 20% of the gait cycle, showing the best trade-off between invasiveness of the setup and accuracy of the classifier. The complexity of the algorithm proved to be significantly higher when applying a polynomial kernel compared to a linear one, while the correct rate of the classifier generally showed no differences between the two approaches. The proposed algorithm led to high performance with a minimal EMG set-up and using only a fraction of the gait duration. Significance. These results pave the way for efficient control of powered lower-limb prostheses with minimal set-up burden and a rapid classification output.

24 June 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
EAEugenio Anselmino
Eugenio Anselmino
AMAlberto Mazzoni
Alberto Mazzoni
SMSilvestro Micera
Silvestro Micera
Lower-limb wearable devices can significantly improve the quality of life of subjects suffering from debilitating conditions, such as amputations, neurodegenerative disorders, and stroke-related impairments. Current control approaches, limited to forward walking, fall short of replicating the complexity of human locomotion in complex environments, such as uneven terrains or crowded places. Here we propose a high-level controller based on two Support Vector Machines exploiting four surface electromyography (EMG) signals of the thigh muscles to detect the onset (Toe-off intention decoder) and the direction (Directional EMG decoder) of the upcoming step. We validated a preliminary version of the approach by acquiring EMG signals from ten healthy subjects, performing steps in four directions (forward, backward, right, and left), in three different settings (ground-level walking, stairs, and ramps), and in both steady-state and static conditions. Both the Toe-off intention and Directional EMG decoders have been tested with a 5-fold cross-validation repeated five times, using linear and radial-basis-function kernels, and by changing the classification output timing, from 200 ms before to 50 ms after the toe-off. The Toe-off intention decoder reached a median accuracy of 83.34 % (interquartile range (IQR): 6.48) and specificity of 92.72 % (IQR: 3.62) in its radial-basis-function version, while the Directional EMG decoder's median accuracy ranged between 73.92 % (IQR: 5.8), 200 ms before the toe-off, to 92.91 % (IQR: 4.11), 50 ms after the toe-off, with the radial-basis-function kernel implementation. For both the Toe-off intention and Directional EMG decoders the radial-basis-function version achieved better performances than the linear one (Wilcoxon signed rank test, p < 0.05). The combination of the two decoders proved to be a promising solution to detect the step initiation and classify its direction, paving the way for wearable devices with a broader range of movements and more degrees of freedom, ultimately promoting usability in uncontrolled settings and better reactions to external perturbations. Additionally, the encumbrance of the setup is limited to the thigh of the leg of interest, which simplifies the implementation in compact devices, concurrently limiting the sensors worn by the subject.

27 March 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
Linda PaternòLinda Paternò
Linda Paternò
MFMariangela Filosa
Mariangela Filosa
EAEugenio Anselmino
Eugenio Anselmino
ACAlessio Cecere
Alessio Cecere
FDFilippo Dell’aGnello
Filippo Dell’aGnello
Arianna MenciassiArianna Menciassi
Arianna Menciassi
In lower limb prostheses, the physical interface constituted by the socket is a crucial component for the device success. This work proposes a new design based on a rigid frame integrated into a silicone structure which allows for a more comfortable biomechanical coupling with the residual limb and facilitates the integration of smart technologies. This paves the way for new possibilities for prosthetic bidirectional interfaces or user health monitoring. Thus, four surface EMG sensors, three vibrotactile units, and nine temperature and humidity sensors have been integrated into the socket. These components enable the users motor intention decoding, provide augmenting feedback, and measure the residual limb thermal condition when wearing the prosthesis. The new socket was tested on a partecipant with a transfemoral amputation. The sEMG signals were registered during five different tasks in a circuit training and the classification median accuracy of an intention decoding algorithm was found to always be higher than 73%. The user’s perception of vibrotactile feedback was assessed through a psychophysical experiment and revealed vibrations from singularly activated units were the best perceived. Questionnaire results confirmed a high satisfaction level. However, tests on temperature and humidity suggest more efforts are still required in terms of skin perspiration.