Workers experiencing high levels of stress may suffer from poor motivation, low level of attention, and physical disorders which, in turn, may lead to work injuries. Respiratory frequency (f R ) is considered one of the most reliable indicators of the mental load and fatigue state of workers. Monitoring this parameter through wearable devices represents an efficient solution for the maintenance of Occupational Health and Safety. We developed an innovative wearable system equipped with flexible sensors based on fiber Bragg gratings (FBGs) to monitor f R in static and dynamic conditions characterizing occupational settings. This article provides a description of the system and of the metrological characteristics of the flexible sensors in terms of response to strain and temperature changes, and hysteresis error. The performances of the device, evaluated in a laboratory during the execution of tasks mimicking real work activity, are also reported. The obtained promising results encourage the engineering of the system for use in real workplaces to collect quantitative information on the psychophysical state of workers and its relation to stress level.
29 May 2022 in Artificial Intelligence in Medicine
The continuous monitoring of an individual's breathing can be an instrument for the assessment and enhancement of human wellness. Specific respiratory features are unique markers of the deterioration of a health condition, the onset of a disease, fatigue and stressful circumstances. The early and reliable prediction of high-risk situations can result in the implementation of appropriate intervention strategies that might be lifesaving. Hence, smart wearables for the monitoring of continuous breathing have recently been attracting the interest of many researchers and companies. However, most of the existing approaches do not provide comprehensive respiratory information. For this reason, a meta-learning algorithm based on LSTM neural networks for inferring the respiratory flow from a wearable system embedding FBG sensors and inertial units is herein proposed. Different conventional machine learning approaches were implemented as well to ultimately compare the results. The meta-learning algorithm turned out to be the most accurate in predicting respiratory flow when new subjects are considered. Furthermore, the LSTM model memory capability has been proven to be advantageous for capturing relevant aspects of the breathing pattern. The algorithms were tested under different conditions, both static and dynamic, and with more unobtrusive device configurations. The meta-learning results demonstrated that a short one-time calibration may provide subject-specific models which predict the respiratory flow with high accuracy, even when the number of sensors is reduced. Flow RMS errors on the test set ranged from 22.03 L/min, when the minimum number of sensors was considered, to 9.97 L/min for the complete setting (target flow range: 69.231 ± 21.477 L/min). The correlation coefficient r between the target and the predicted flow changed accordingly, being higher (r = 0.9) for the most comprehensive and heterogeneous wearable device configuration. Similar results were achieved even with simpler settings which included the thoracic sensors (r ranging from 0.84 to 0.88; test flow RMSE = 10.99 L/min, when exclusively using the thoracic FBGs). The further estimation of respiratory parameters, i.e., rate and volume, with low errors across different breathing behaviors and postures proved the potential of such approach. These findings lay the foundation for the implementation of reliable custom solutions and more sophisticated artificial intelligence-based algorithms for daily life health-related applications.
24 April 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
The effectiveness of haptic feedback devices highly depends on the perception of tactile stimuli, which differs across body parts and can be affected by movement. In this study, a novel wearable sensory feedback apparatus made of a pair of pressure-sensitive insoles and a belt equipped with vibrotactile units is presented; the device provides time-discrete vibrations around the waist, synchronized with biomechanically-relevant gait events during walking. Experiments with fifteen healthy volunteers were carried out to investigate users’ tactile perception on the waist. Stimuli of different intensities were provided at twelve locations, each time synchronously with one pre-defined gait event (i.e. heel strike, flat foot or toe off), following a pseudo-random stimulation sequence. Reaction time, detection rate and localization accuracy were analyzed as functions of the stimulation level and site and the effect of gait events on perception was investigated. Results revealed that above-threshold stimuli (i.e. vibrations characterized by acceleration amplitudes of 1.92g and 2.13g and frequencies of 100 Hz and 150 Hz, respectively) can be effectively perceived in all the sites and successfully localized when the intertactor spacing is set to 10 cm. Moreover, it was found that perception of time-discrete vibrations was not affected by phase-related gating mechanisms, suggesting that the waist could be considered as a preferred body region for delivering haptic feedback during walking.
In the food and medical packaging industries, clean packaging is crucial to both customer satisfaction and hygiene. An operational Quality Assurance Department (QAD) is necessary for detecting contaminated packages. Manual examination becomes tedious and may lead to instances of contamination being missed along the production line. To address this issue, a system for contamination detection is proposed using an enhanced deep convolutional neural network (CNN) in a human–robot collaboration framework. The proposed system utilizes a CNN to identify and classify the presence of contaminants on product surfaces. A dataset is generated, and augmentation methods are applied to the dataset for nine classes such as coffee, spot, chocolate, tomato paste, jam, cream, conditioner, shaving cream, and toothpaste contaminants. The experiment was conducted using a mechatronic platform with a camera for contamination detection and a time-of-flight sensor for safe machine–environment interaction. The results of the experiment indicate that the reported system can accurately identify contamination with 99.74% mean average precision (mAP).
The sense of touch is essential for humans to perceive, locate and react to physical stimuli. Notwithstanding the substantial advancements in e-skin research and related applications with collaborative robots and bionic prostheses, biomimetic intelligence remains a challenge in the attempt to understand and mimic somatosensory processing schemes. In this work, we present a large-area e-skin embedded with photonic fibre Bragg gratings, capable of decoding touch localization through a bioinspired two-layered spiking neuronal network. The implemented biomimicry of slowly adapting and fast-adapting type II primary afferents, cuneate neurons with overlapping receptive fields and neuroplasticity, enable unsupervised learning in localizing tactile stimuli with an error lower than 10 mm, and two-point discrimination thresholds matching human psychophysical thresholds in the forearm. These results align with biological findings and offer a promising step towards the development of bionic systems, opening new avenues for both practical applications and scientific explorations of somatosensation.
27 March 2024 in IEEE Transactions on Medical Robotics and Bionics
In lower limb prostheses, the physical interface constituted by the socket is a crucial component for the device success. This work proposes a new design based on a rigid frame integrated into a silicone structure which allows for a more comfortable biomechanical coupling with the residual limb and facilitates the integration of smart technologies. This paves the way for new possibilities for prosthetic bidirectional interfaces or user health monitoring. Thus, four surface EMG sensors, three vibrotactile units, and nine temperature and humidity sensors have been integrated into the socket. These components enable the users motor intention decoding, provide augmenting feedback, and measure the residual limb thermal condition when wearing the prosthesis. The new socket was tested on a partecipant with a transfemoral amputation. The sEMG signals were registered during five different tasks in a circuit training and the classification median accuracy of an intention decoding algorithm was found to always be higher than 73%. The user’s perception of vibrotactile feedback was assessed through a psychophysical experiment and revealed vibrations from singularly activated units were the best perceived. Questionnaire results confirmed a high satisfaction level. However, tests on temperature and humidity suggest more efforts are still required in terms of skin perspiration.