Aashish Goela

Aashish Goela

Auto-generated profile, based on publicly available information

Aashish Goela

University of Western Ontario

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MAMariam Afshin
Mariam Afshin
IAIsmail Ben Ayed
Ismail Ben Ayed
KPKumaradevan Punithakumar
Kumaradevan Punithakumar
MLMax Law
Max Law
AIAli Islam
Ali Islam
SLShuo Li
Shuo Li
Automating the detection and localization of segmental (regional) left ventricle (LV) abnormalities in magnetic resonance imaging (MRI) has recently sparked an impressive research effort, with promising performances and a breadth of techniques. However, despite such an effort, the problem is still acknowledged to be challenging, with much room for improvements in regard to accuracy. Furthermore, most of the existing techniques are labor intensive, requiring delineations of the endo- and/or epi-cardial boundaries in all frames of a cardiac sequence. The purpose of this study is to investigate a real-time machine-learning approach which uses some image features that can be easily computed, but that nevertheless correlate well with the segmental cardiac function. Starting from a minimum user input in only one frame in a subject dataset, we build for all the regional segments and all subsequent frames a set of statistical MRI features based on a measure of similarity between distributions. We demonstrate that, over a cardiac cycle, the statistical features are related to the proportion of blood within each segment. Therefore, they can characterize segmental contraction without the need for delineating the LV boundaries in all the frames. We first seek the optimal direction along which the proposed image features are most descriptive via a linear discriminant analysis. Then, using the results as inputs to a linear support vector machine classifier, we obtain an abnormality assessment of each of the standard cardiac segments in real-time. We report a comprehensive experimental evaluation of the proposed algorithm over 928 cardiac segments obtained from 58 subjects. Compared against ground-truth evaluations by experienced radiologists, the proposed algorithm performed competitively, with an overall classification accuracy of 86.09% and a kappa measure of 0.73.

1 June 2009 in The American Journal of Medicine
Verified
Journal Article
Closed access
SLSam J. Lehman
Sam J. Lehman
SASuhny Abbara
Suhny Abbara
RCRicardo C. Cury
Ricardo C. Cury
JNJohn T. Nagurney
John T. Nagurney
JHJoe Hsu
Joe Hsu
UHUdo Hoffmann
Udo Hoffmann

1 December 2013 in Medical Image Analysis
Verified
Journal Article
Closed access
CNCyrus M.S. Nambakhsh
Cyrus M.S. Nambakhsh
JYJing Yuan
Jing Yuan
KPKumaradevan Punithakumar
Kumaradevan Punithakumar
AGAashish Goela
Aashish Goela
MRMartin Rajchl
Martin Rajchl
IAIsmail Ben Ayed
Ismail Ben Ayed

1 April 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ZWZhijie Wang
Zhijie Wang
MSMohamed Ben Salah
Mohamed Ben Salah
BGBin Gu
Bin Gu
AIAli Islam
Ali Islam
AGAashish Goela
Aashish Goela
SLShuo Li
Shuo Li
Accurate estimation of the ventricular volumes is essential to the assessment of global cardiac functions. The existing estimation methods are mostly restricted to the left ventricle (LV), and often require segmentation which is challenging and computationally expensive. This paper proposes to estimate the volumes of both LV and right ventricle (RV) jointly with an efficient segmentation-free method. The proposed method employs an adapted Bayesian formulation. It introduces a novel likelihood function to exploit multiple appearance features, and a novel prior probability model to incorporate the area correlation between LV and RV cavities. The method is validated on a comprehensive dataset containing 56 clinical subjects (3360 images in total). The experimental results demonstrate that the estimated biventricular volumes are highly correlated to their independent ground truth. As a result, the proposed method enables a direct, efficient, and accurate assessment of global cardiac functions.

1 July 2013 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
JWJorge A. Wong
Jorge A. Wong
RYRaymond Yee
Raymond Yee
JSJohn Stirrat
John Stirrat
DSDavid Scholl
David Scholl
AKAndrew D. Krahn
Andrew D. Krahn
JWJames A. White
James A. White
Background—: Transmural scar occupying left ventricular (LV) pacing regions has been associated with reduced response to cardiac resynchronization therapy (CRT). However, spatial influences of lead tip delivery relative to scar at both pacing sites remain poorly explored. This study evaluated scar distribution relative to LV and right ventricular (RV) lead tip placement through coregistration of late gadolinium enhancement MRI and cardiac computed tomographic (CT) findings. Influences on CRT response were assessed by serial echocardiography. Methods and Results—: Sixty patients receiving CRT underwent preimplant late gadolinium enhancement MRI, postimplant cardiac CT, and serial echocardiography. Blinded segmental evaluations of mechanical delay, percentage scar burden, and lead tip location were performed. Response to CRT was defined as a reduction in LV end-systolic volume ≥15% at 6 months. The mean age and LV ejection fraction were 64±9 years and 25±7%, respectively. Mean scar volume was higher among CRT nonresponders for both the LV (23±23% versus 8±14% [ P =0.01]) and RV pacing regions (40±32% versus 24±30% [ P =0.04]). Significant pacing region scar was identified in 13% of LV pacing regions and 37% of RV pacing regions. Absence of scar in both regions was associated with an 81% response rate compared with 55%, 25%, and 0%, respectively, when the RV, LV, or both pacing regions contained scar. LV pacing region dyssynchrony was not predictive of response. Conclusions—: Myocardial scar occupying the LV pacing region is associated with nonresponse to CRT. Scar occupying the RV pacing region is encountered at higher frequency and seems to provide a more intermediate influence on CRT response.

1 April 2013 in Medical Image Analysis
Verified
Journal Article
Closed access
KPKumaradevan Punithakumar
Kumaradevan Punithakumar
IAIsmail Ben Ayed
Ismail Ben Ayed
AIAli Islam
Ali Islam
AGAashish Goela
Aashish Goela
IRIan G. Ross
Ian G. Ross
SLShuo Li
Shuo Li