Roger Karl

Roger Karl

Auto-generated profile, based on publicly available information

Roger Karl

Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LBLukas Burger
Lukas Burger
LSLalith Sharan
Lalith Sharan
RKRoger Karl
Roger Karl
CWChristina Wang
Christina Wang
MKMatthias Karck
Matthias Karck
SESandy Engelhardt
Sandy Engelhardt
Purpose: Minimally invasive surgeries have restricted surgical ports, demanding a high skill level from the surgeon. Surgical simulation potentially reduces this steep learning curve and additionally provides quantitative feedback. Markerless depth sensors show great promise for quantification, but most such sensors are not designed for accurate reconstruction of complex anatomical forms in close-range. Methods: This work compares three commercially available depth sensors, namely the Intel D405, D415, and the Stereolabs Zed-Mini in the range of 12–20 cm, for use in surgical simulation. Three environments are designed that closely mimic surgical simulation, comprising planar surfaces, rigid objects, and mitral valve models of silicone and realistic porcine tissue. The cameras are evaluated on Z-accuracy, temporal noise, fill rate, checker distance, point cloud comparisons, and visual inspection of surgical scenes, across several camera settings. Results: The Intel cameras show sub-mm accuracy in most static environments. The D415 fails in reconstructing valve models, while the Zed-Mini provides lesser temporal noise and higher fill rate. The D405 could reconstruct anatomical structures like the mitral valve leaflet and a ring prosthesis, but performs poorly for reflective surfaces like surgical tools and thin structures like sutures. Conclusion: If a high temporal resolution is needed and lower spatial resolution is acceptable, the Zed-Mini is the best choice, whereas the Intel D405 is the most suited for close-range applications. The D405 shows potential for applications like deformable registration of surfaces, but is not yet suitable for applications like real-time tool tracking or surgical skill assessment.

8 December 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
RKRoger Karl
Roger Karl
GRGabriele Romano
Gabriele Romano
JMJosephin Marx
Josephin Marx
MEMatthias Eden
Matthias Eden
PSPhilipp Schlegel
Philipp Schlegel
SESandy Engelhardt
Sandy Engelhardt
Purpose: Minimally invasive mitral valve surgery (MIMVS) and transcatheter edge-to-edge repair (TEER) are complex procedures used to treat mitral valve (MV) pathologies, but with limited training opportunities available. To enable training, a realistic hemodynamic environment is needed. In this work we aimed to develop and validate a simulator that enables investigation of MV pathologies and their repair by MIMVS and TEER in a hemodynamic setting. Methods: Different MVs were installed in the simulator, and pressure, flow, and transesophageal echocardiographic measurements were obtained. To confirm the simulator’s physiological range, we first installed a biological prosthetic, a mechanical prosthetic, and a competent excised porcine MV. Subsequently, we inserted two porcine MVs—one with induced chordae tendineae rupture and the other with a dilated annulus, along with a patient-specific silicone valve extracted from echocardiography with bi-leaflet prolapse. Finally, TEER and MIMVS procedures were conducted by experts to repair the MVs. Results: Systolic pressures, cardiac outputs, and regurgitations volumes (RVol) with competent MVs were 119 ± 1 mmHg, 4.78 ± 0.16 l min−1, and 5 ± 3 ml respectively, and thus within the physiological range. In contrast, the pathological MVs displayed increased RVols. MIMVS and TEER resulted in a decrease in RVols and mitigated the severity of mitral regurgitation. Conclusion: Ex-vivo modelling of MV pathologies and repair procedures using the described simulator realistically replicated physiological in-vivo conditions. Furthermore, we showed the feasibility of performing MIMVS and TEER at the simulator, also at patient-specific level, thus providing new clinical perspectives in terms of training modalities and personalized planning.

7 June 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LMLukas Mohl
Lukas Mohl
RKRoger Karl
Roger Karl
MHMatthias N. Hagedorn
Matthias N. Hagedorn
ARArmin Runz
Armin Runz
SSStephan Skornitzke
Stephan Skornitzke
SESandy Engelhardt
Sandy Engelhardt
Purpose: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. Methods: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. Results: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. Conclusions: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.

21 November 2023 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
CWChristina Wang
Christina Wang
RKRoger Karl
Roger Karl
LSLalith Sharan
Lalith Sharan
AGAndela Grizelj
Andela Grizelj
SFSamantha Fischer
Samantha Fischer
SESandy Engelhardt
Sandy Engelhardt
OBJECTIVES: Minimally invasive mitral valve repair (MVR) is considered one of the most challenging operations in cardiac surgery and requires much practice and experience. Simulation-based surgical training might be a method to support the learning process and help to flatten the steep learning curve of novices. The purpose of this study was to show the possible effects on learning of surgical training using a high-fidelity simulator with patient-specific mitral valve replicas. METHODS: Twenty-five participants were recruited to perform MVR on anatomically realistic valve models during different training sessions. After every session their performance was evaluated by a surgical expert regarding accuracy and duration for each step. A second blinded rater similarly assessed the performance after the study. Through repeated documentation of those parameters, their progress in learning was analysed, and gains in proficiency were evaluated. RESULTS: Participants showed significant performance enhancements in terms of both accuracy and time. Their surgical skills showed sizeable improvements after only 1 session. For example, the time to implant neo-chordae decreased by 24.64% (354 s-264 s, P < 0.001) and the time for annuloplasty by 4.01% (54 s-50 s, P = 0.165), whereas the number of irregular stitches for annuloplasty decreased from 52% to 24%. The significance of simulation-based surgical training as a tool for acquiring and training surgical skills was reviewed positively. CONCLUSIONS: The results of this study indicate that simulation-based surgical training is a valuable and effective method for learning reconstructive techniques of minimally invasive MVR and overall general dexterity. The novel learning and training options should be implemented in the surgical traineeship for systematic teaching of various surgical skills.

6 January 2025 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
RLRobin Leister
Robin Leister
RKRoger Karl
Roger Karl
LSLubov Stroh
Lubov Stroh
DMDerliz Mereles
Derliz Mereles
MEMatthias Eden
Matthias Eden
SESandy Engelhardt
Sandy Engelhardt
The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise. The present work systematically compares different pulsatile flow profiles arising from different regurgitation orifices using transesophageal echocardiographic (TEE) probe and particle image velocimetry (PIV) as a reference in an in-vitro environment. It is found that the inter-observer variability using echocardiography is small compared to the systematic underestimation of the regurgitation volume for large orifice areas (up to 52%) where a violation of the flow convergence method assumptions occurs. From a flow perspective, a starting vortex was found as a dominant flow pattern in the regurgant jet for all orifice shapes and sizes. A series of simplified computational fluid dynamics (CFD) simulations indicate that selecting a suboptimal aliasing velocity during echocardiography measurements might be a primary source of potential underestimation in MR characterization via the PISA-based method, reaching up to 40%. In this study, it has been noted in clinical observations that physicians often select an aliasing velocity higher than necessary for optimal estimation in diagnostic procedures.

22 July 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
RKRoger Karl
Roger Karl
DRDominic P. Recco
Dominic P. Recco
SKShannen Kizilski
Shannen Kizilski
IAIbrahim Tharwat Abdelmoneim
Ibrahim Tharwat Abdelmoneim
NKNicholas Kneier
Nicholas Kneier
PHPeter E. Hammer
Peter E. Hammer
Purpose: Secondary chordae tendineae (CT) are frequently disregarded during mitral valve (MV) repair. However, their contribution to MV biomechanics remains poorly understood. We hypothesized that secondary CT play an important role in maintaining leaflet geometry during valve closure. Methods: Eleven explanted porcine MVs were micro-CT scanned in a systolic configuration under three conditions: (1) physiological baseline with all secondary CT intact, (2) transection of the A2 strut CT, and (3) transection of all secondary CT. Billowing height (BH), coaptation height (CH) along the parasternal long-axis view, and coaptation area (CA) were quantified and compared between conditions. An increase in BH ≥2 mm from baseline was defined as pathological. Results: Transection of the A2 strut CT increased BH by 3.1 mm, exceeding the pathological billowing threshold by 1.1 mm (padj = 0.003). CH decreased by 0.6 mm (padj = 0.003), whereas CA showed no significant change compared with baseline. Subsequent transection of all secondary CT further increased BH to 4.8 mm relative to baseline, corresponding to 2.8 mm above the billowing threshold (padj = 0.003). CH did not differ significantly, while CA decreased by 0.35 cm2 compared with baseline (padj = 0.029). All values represent medians. Conclusion: Secondary CT play a critical role in stabilizing MV leaflet geometry. Their transection resulted in increased leaflet billowing and reduced coaptation metrics associated with unfavorable MV repair outcomes. Preservation or reconstruction of secondary CT may therefore be an important consideration in MV repair strategies.