7 June 2024 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. Methods: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. Results: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. Conclusions: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.
20 April 2021 in Gefässchirurgie
4 September 2023 in Indian Journal of Thoracic and Cardiovascular Surgery
Long-term outcome after thoracic endovascular aortic repair (TEVAR) of acute type B aortic dissection (aTBAD) is still underreported in current literature. This case report shows persistence of aortic remodeling without secondary complication or need of reintervention 13 years after TEVAR. A 45-year-old woman was referred to the emergency room with aTBAD. Due to early diameter progression in combination with therapy-refractory pain and uncontrolled hypertension, TEVAR was performed. Hereafter, the patient showed complete remodeling of the descending thoracic aorta without persistent false lumen perfusion in this segment and with stable true and false lumen diameter in the untreated abdominal segment for a 13-year period. No aortic-related reintervention was needed. With contemporary devices and adapted therapy, TEVAR seems able to treat complex thoracic disease. Long-term follow-up (FU) is mandatory to monitor the efficacy and durability of endovascular treatment in aortic disease.
23 September 2025 in Journal of Vascular Surgery Cases, Innovations and Techniques
Patient-specific three-dimensional-printed phantoms have emerged as valuable tools for simulating Stanford type B aortic dissections in vitro, enabling detailed studies of dissection morphology, hemodynamics, and interventional techniques under controlled, anatomically realistic conditions. Despite their potential, current methodologies remain heterogeneous and lack standardization. This scoping review, compliant with the PRISMA guidelines, systematically evaluated literature describing additive-manufactured flexible aortic phantoms specifically for pulsatile flow experiments or endovascular procedures. From an initial pool of 120 publications, five studies met the inclusion criteria, all using clinical imaging data and PolyJet-technology with flexible photopolymers. Four studies used full-scale models to simulate hemodynamics or thoracic endovascular aortic repair, and one investigated imaging properties in smaller segments. Although these phantoms reliably replicate dissection anatomy and flow patterns, widespread adoption is constrained by resource demands, simplified wall mechanics, exclusion of smaller vessel branches, and variable fabrication methods. Additional limitations include material durability and single-use designs. Standardizing fabrication protocols and developing advanced biomimetic materials could significantly enhance the physiological accuracy, reproducibility, and practicality of these models. Patient-specific three-dimensional-printed type B aortic dissections phantoms thus represent potentially valuable tools for improving surgical training, procedural rehearsal, morphological insights, and device innovation, ultimately bridging benchtop simulations and clinical practice.