Violeta Misevičiūtė

Violeta Misevičiūtė

Auto-generated profile, based on publicly available information

Violeta Misevičiūtė

Vilnius Gediminas Technical University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in International Journal of Environmental Science and Development
Verified
Journal Article
Open access
KJKarolis Janusevicius
Karolis Janusevicius
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
VMVioleta Misevičiūtė
Violeta Misevičiūtė

6 January 2022 in Mokslas - Lietuvos ateitis
Verified
Journal Article
Open access
PDF file
ARArtur Rogoža
Artur Rogoža
VMVioleta Misevičiūtė
Violeta Misevičiūtė
The main users of district heating (DH) systems are multi-apartment buildings – 53% of these buildings in Lithuania are supplied with heat from DH systems. Heating systems in buildings are the largest final consumer of energy, accounting for almost half of total energy consumption in many European countries. One of the measures planned for the Lithuanian energy policy in the heat sector of renewable energy sources (RES) until 2030 is the installation of heat pumps (HP) in the DH networks. The purpose of the study is to evaluate the technological possibilities of integrating HP into existing buildings to evaluate the low temperature heat supply. To evaluate the potential temperature lowering of the building heating system, a graph of the lowest possible building heating system temperatures is set, according to which the heat pump for the heating substation is selected, which would raise the temperature of the heat carrier supplied from DH networks to the required temperature for the heating and hot water systems of the building. Applying thermodynamic analysis, a mathematical model is developed that evaluates the ability of the HP to raise the temperature of the supplied heat carrier at the heat substation and determines the energy efficiency of such a solution. During the simulation, two alternatives of constant (regardless of outdoor air temperature) heat carrier temperatures supplied from DH networks were considered: 60 °C (alternative A) and 55 °C (alternative B). To adapt the most appropriate option for the integration of HP, it would be appropriate to combine both alternatives, i. y. to supply 60 °C from the DH network in the cold period of the year and 55 °C in the warm period of the year. Article in Lithuanian. Šilumos siurblių taikymo centralizuotai aprūpinant daugiabučius pastatus šiluma technologinių galimybių tyrimas Santrauka Pagrindiniai centralizuoto šilumos tiekimo (CŠT) sistemų vartotojai yra daugiabučiai pastatai – 53 procentai šių pastatų Lietuvoje aprūpinama šiluma iš CŠT sistemų. Pastatų šildymo sistemos yra didžiausias galutinis energijos vartotojas, kuris sudaro beveik pusę viso energijos suvartojimo daugelyje Europos šalių. Viena iš planuojamų Lietuvos energetinės politikos priemonių atsinaujinančių energijos išteklių (AEI) šilumos sektoriuje iki 2030 m. yra šilumos siurblių (ŠS) diegimas CŠT tinkluose. Tyrimo tikslas yra įvertinti technologines galimybes esamuose pastatuose integruoti ŠS, siekiant taikyti žemos temperatūros šilumos tiekimą. Siekiant įvertinti pastato šildymo sistemos temperatūrų žeminimo potencialą, nustatomas žemiausių galimų pastato šildymo sistemos temperatūrų grafikas, pagal kurį pastato šilumos punktui parenkamas ŠS, kuris pažemintą iš CŠT sistemų tiekiamą šilumnešio temperatūrą pakeltų iki reikiamos pastato šildymo ir karšto vandens sistemoms temperatūros. Taikant termodinaminę analizę sukurtas matematinis modelis, įvertinantis ŠS galimybes pakelti tiekiamo šilumnešio temperatūrą šilumos punkte ir nustatantis tokio sprendimo energinį efektyvumą. Modeliavimo metu nagrinėtos dvi tiekiamo iš CŠT tinklų pastovių (nepriklausomai nuo lauko oro temperatūros) šilumnešio temperatūrų alternatyvos – 60 °C (alternatyva A) ir 55 °C (alternatyva B). Siekiant pritaikyti tinkamiausią ŠS integravimo variantą, būtų tikslinga derinti abi alternatyvas, t. y. šaltuoju metų laikotarpiu iš CŠT tinklo tiekti 60 °C, o šiltuoju metų laikotarpiu – 55 °C šilumnešį. Reikšminiai žodžiai: centralizuotas šilumos tiekimas, daugiabutis namas, šilumos siurblys, žemos temperatūros šilumos tiekimas, šilumos nuostoliai tinkle.

1 January 2011 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
VMVioleta Miseviciute
Violeta Miseviciute
The installation of a heat storage tank is a very cost-effective way to improve the performance and flexibility of a CHP plant. Such a heat storage tank usually accumulates heat by thermal stratification. This phenomenon is caused by the thermal buoyancy because of the difference in temperature between cold and hot water. The heat storage tank may have three operating modes, i. e. charge, discharge and storage in a CHP plant. When CHP units, which charge the heat storage tank, operate at full load, usually only two operation modes occur in the tank, i.e. charge and discharge. The paper presents numerical simulation of heat storage tank operation modes in a CHP plant using PHOENICS - a multi-purpose computation fluid dynamics (CFD) software. Two-dimensional and three-dimensional transient models were created and solved numerically. Three domain grids were tested. Several charging and discharging processes with different flow rates were simulated. The influence of flow rate on the degree of thermal stratification during charging and discharging processes is analyzed. The computation possibilities and limitations of the numerical experiments are pointed out. Special attention is given to the validation of the numerical solutions. The validation of simulated results is made by comparison with the real data from the heat storage installed in the Hvide Sande CHP plant.

7 April 2025 in Mokslas - Lietuvos ateitis
Verified
Journal Article
Open access
PDF file
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
Juozas BielskusJuozas Bielskus
Juozas Bielskus
ARArtur Rogoža
Artur Rogoža
VLVilune Lapinskiene
Vilune Lapinskiene
VMVioleta Misevičiūtė
Violeta Misevičiūtė
Any renovation of apartment buildings by replacing or keeping their heating devices usually means that high temperatures of the heat carrier are maintained, which restricts boosting the efficiency of a central heating supply system. This also limits the scope for a switch to more efficient systems such as low-temperature district heating systems. To assess the impact of reducing the heat carrier temperature on indoor heating with a constant radiator area, the article investigates several alternatives alongside a base case scenario. In one scenario, the modernization of a building is examined, either by retaining the current heating devices or by substituting them with devices of equal size. Another scenario explores the modernization of a building by exchanging the heating devices and adjusting the building’s heating system to accommodate ultra-low temperatures. The possibility to reduce the temperature of the heat carrier in the heating system without any renovation of the building has been addressed as well. This led to seven alternatives. The analysis of the hourly data of the heating system model for two typical months in a heating season has revealed that when the building retains its existing area of heating devices post-renovation, the temperature can be brought down to 60/40/20 °C. It was also discovered that lowering the heat transfer temperature to ultra-low parameters (45/25/20 °C) cannot be achieved by refurbishing the buildings without increasing the number of radiators, as the heating devices will fail to deliver adequate heat for space heating.

8 July 2024 in Rocznik Ochrona Środowiska
Verified
Journal Article
Open access
VMVioleta Misevičiūtė
Violeta Misevičiūtė
ARArtur Rogoža
Artur Rogoža
RTRapolas Tučkus
Rapolas Tučkus
It is important to address the world‘s energy crisis, increasing energy demand and changing climate by finding ways to recover unused energy and minimise primary and secondary energy use and emissions. The natural gas sector, which consists of the transmission network and gas distribution stations, is an important part of the global and Lithuanian energy sector. However, due to the operating principle of gas pressure regulators, the energy potential of high-pressure gas is not efficiently utilized in gas distribution stations. As a result, natural gas boilers are used for gas preheating, and gas distribution stations cause additional environmental pollution. This study aims to find ways to optimise the efficiency of gas distribution stations and reduce their negative environmental impact by identifying areas where energy is wasted and proposing alternative technological solutions: turbine expander (as an alternative for gas pressure regulator), ground heat pumps, solar collectors and photovoltaic solar cells (as gas preheating alternatives). The best alternative technological solution for the gas distribution station is evaluated based on energy efficiency, economic viability, and environmental impact (3E criteria).

17 July 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
Juozas BielskusJuozas Bielskus
Juozas Bielskus
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
DRDovydas Rimdžius
Dovydas Rimdžius
KVKęstutis Valančius
Kęstutis Valančius
VMVioleta Misevičiūtė
Violeta Misevičiūtė