Brandon C. Jones

Brandon C. Jones

Auto-generated profile, based on publicly available information

Brandon C. Jones

Department of Radiology, University of Pennsylvania, United States of America

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Radiology
Verified
Journal Article
Closed access
BJBrandon C. Jones
Brandon C. Jones
HLHyunyeol Lee
Hyunyeol Lee
CCCheng-Chieh Cheng
Cheng-Chieh Cheng
MMMona al Mukaddam
Mona al Mukaddam
HSHee Kwon Song
Hee Kwon Song
FWFelix W. Wehrli
Felix W. Wehrli
Background Preclinical studies have suggested that solid-state MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are useful measures of bone health. Purpose To explore whether MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are affected in postmenopausal osteoporosis (OP) and to examine associations between MRI markers and bone mineral density (BMD) in postmenopausal women. Materials and Methods In this single-center study, postmenopausal women were prospectively recruited from January 2019 to October 2020 into two groups: participants with OP who had not undergone treatment, defined as having any dual-energy x-ray absorptiometry (DXA) T-score of -2.5 or less, and age-matched control participants without OP (hereafter, non-OP). Participants underwent MRI in the midtibia, along with DXA in the hip and spine, and peripheral quantitative CT in the midtibia. Specifically, MRI measures of cortical bone porosity (pore water and total water), osteoid density (bound water [BW]), morphologic structure (cortical bone thickness), and mineralization (phosphorous [P] density [31P] and 31P-to-BW concentration ratio) were quantified at 3.0 T. MRI measures were compared between OP and non-OP groups and correlations with BMD were assessed. Results Fifteen participants with OP (mean age, 63 years ± 5 [SD]) and 19 participants without OP (mean age, 65 years ± 6) were evaluated. The OP group had elevated pore water (11.6 mol/L vs 9.5 mol/L; P = .007) and total water densities (21.2 mol/L vs 19.7 mol/L; P = .03), and had lower cortical bone thickness (4.8 mm vs 5.6 mm; P < .001) and 31P density (6.4 mol/L vs 7.5 mol/L; P = .01) than the non-OP group, respectively, although there was no evidence of a difference in BW or 31P-to-BW concentration ratio. Pore and total water densities were inversely associated with DXA and peripheral quantitative CT BMD (P < .001), whereas cortical bone thickness and 31P density were positively associated with DXA and peripheral quantitative CT BMD (P = .01). BW, 31P density, and 31P-to-BW concentration ratio were positively associated with DXA (P < .05), but not with peripheral quantitative CT. Conclusion Solid-state MRI of cortical bone was able to help detect potential impairments in parameters reflecting porosity, morphologic structure, and mineralization in postmenopausal osteoporosis. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bae in this issue.

1 December 2019 in Bone Reports
Verified
Journal Article
Open access
AHAbigail L. Hong
Abigail L. Hong
MIMikayel Ispiryan
Mikayel Ispiryan
MPMugdha V. Padalkar
Mugdha V. Padalkar
BJBrandon C. Jones
Brandon C. Jones
ABAlexandra S. Batzdorf
Alexandra S. Batzdorf
CRChamith S. Rajapakse
Chamith S. Rajapakse
The MRI-derived porosity index (PI) is a non-invasively obtained biomarker based on an ultrashort echo time sequence that images both bound and pore water protons in bone, corresponding to water bound to organic collagenous matrix and freely moving water, respectively. This measure is known to strongly correlate with the actual volumetric cortical bone porosity. However, it is unknown whether PI may also be able to directly quantify bone organic composition and/or mechanical properties. We investigated this in human cadaveric tibiae by comparing PI values to near infrared spectral imaging (NIRSI) compositional data and mechanical compression data. Data were obtained from a cohort of eighteen tibiae from male and female donors with a mean ± SD age of 70 ± 21 years. Biomechanical stiffness in compression and NIRSI-derived collagen and bound water content all had significant inverse correlations with PI (r = -0.79, -0.73, and -0.95 and p = 0.002, 0.007, and <0.001, respectively). The MRI-derived bone PI alone was a moderate predictor of bone stiffness (R 2 = 0.63, p = 0.002), and multivariate analyses showed that neither cortical bone cross-sectional area nor NIRSI values improved bone stiffness prediction compared to PI alone. However, NIRSI-obtained collagen and water data together were a moderate predictor of bone stiffness (R2 = 0.52, p = 0.04). Our data validates the MRI-derived porosity index as a strong predictor of organic composition of bone and a moderate predictor of bone stiffness, and also provides preliminary evidence that NIRSI measures may be useful in future pre-clinical studies on bone pathology.

1 April 2020 in Bone
Verified
Journal Article
Closed access
CRChamith S. Rajapakse
Chamith S. Rajapakse
AFAlexander R. Farid
Alexander R. Farid
DKDaniel C. Kargilis
Daniel C. Kargilis
BJBrandon C. Jones
Brandon C. Jones
JLJae S. Lee
Jae S. Lee
GCGregory Chang
Gregory Chang

1 January 2022 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
ASAbhinav Suri
Abhinav Suri
BJBrandon C. Jones
Brandon C. Jones
GNGrace Ng
Grace Ng
NANancy Anabaraonye
Nancy Anabaraonye
PBPatrick Beyrer
Patrick Beyrer
CRChamith S. Rajapakse
Chamith S. Rajapakse
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...

20 November 2018 in Physical Review Materials
Verified
Journal Article
Open access
PDF file
TSTroy Shinbrot
Troy Shinbrot
BJBrandon Jones
Brandon Jones
PSPranav Saba
Pranav Saba
It has been proposed [L. S McCarty and G. M Whitesides, Angew. Chem., Int. Ed. 47, 2188 (2008); Lee et al., Phys. Rev. Mater. 2, 035602 (2018)] that contact charging between insulators may be mediated by nonequilibrium transport of adsorbed ions. We remark here that if adsorbed ions transport charges between surfaces, they could equally transport charges across a single surface. We test this hypothesis by contacting initially neutral insulating spheres. We find that localized charge patterns appear very far (centimeters) from a point of contact. We visualize the charges, evaluate their spatial distributions, and discuss mechanisms and implications of this apparent action at a distance.

3 March 2016 in European Journal of Computational Mechanics
Verified
Journal Article
Closed access
MDM. Denda
M. Denda
PJPruthvi K. Jujjavarapu
Pruthvi K. Jujjavarapu
BJBrandon C. Jones
Brandon C. Jones
This paper considers 2D insect wing motion in which the flow field does not change in the out-of-plane direction. When modelling complex phenomena, simpler, but not overly simple, analysis techniques become imperative. We achieve the balance of simplicity and accuracy by a technique based on the vortex. The wing is represented by its chord, described by a line in 2D. During the unsteady flapping, a time-dependent circulation pattern is developed over the wing, modelled by the distribution of discrete line vortices. The magnitudes of the bound vortices on the wing are determined by the non-penetration condition. Two vortices at the wing’s leading and trailing edges are shed. The velocity is determined by the bound and wake vortices using 2D Biot–Savart law, which is also used to convect wake vortices. The entire cycle is repeated as the time progresses. While establishing a simple affordable numerical method for flapping wing analysis and highlighting its remarkable performance, the limitation of the method is delineated and recommendations made in comparison with more accurate solutions obtained by a Navier–Stokes solver. This will ensure the proper use of the method and avoid its misuse in the unsteady aerodynamics analysis.