Jéssica Leite Fogaça

Jéssica Leite Fogaça

Auto-generated profile, based on publicly available information

Jéssica Leite Fogaça

Universidade Estadual Paulista, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Verified
Journal Article
Open access
PDF file
JAJ.M. Alonso
J.M. Alonso
FSF.P. Schmitt
F.P. Schmitt
FSF.A.L. Sousa
F.A.L. Sousa
GRGustavo Rosa
Gustavo Rosa
CEC.S. Esper
C.S. Esper
Carlos Alberto HussniCarlos Alberto Hussni
Carlos Alberto Hussni
The aim of this study was to evaluate the effects of Psyllium (PSY) and Carboxymethylcellulose (CMC) administration on fecal elimination of sand in horses with asymptomatic sand accumulations. Eight horses were selected from sandy areas and randomly divided into 2 groups of four animals. The subjects were treated either with CMC or PSY. The presence of intestinal sand was confirmed through radiography and glove sedimentation test. The study was performed in two phases, with a 7-day interval. In phase I, all the animals received 8 liters of warm water; in phase II, the CMC group received 8 liters of water + 1g/kg of CMC, whereas the PSY group received 8 liters of water + 1g/kg of PSY. All administrations were performed through nasogastric intubation and fractionated in 2 equal volume administrations with an interval of two hours. General and specific physical examination of the digestive system were performed in conjunction with abdominal ultrasonography before the administrations and after 6, 12, 24, 36 and 48 hours, aiming to evaluate intestinal motility and presence of sand. All the feces eliminated by the animals within the 72 hours following the administrations were quantified, diluted and sedimented in order to calculate the sand output (g/kg of feces). All the animals were also subjected to radiographic examination to quantify sand accumulation prior to phase I and after 72 hours of phases I and II. No adverse effects were observed after the treatments. It was possible to notice higher sand elimination in both groups during the phase I, whereas no difference was observed in sand elimination rates between the groups in phase II. The radiographic scores presented differences between the initial timepoint and 72h in phases I and II for both groups. Based on the sand elimination rates and radiographic score, this study demonstrated that sand output was greater after administration of water alone, compared to CMC and Psyllium, leading to the inference that removal of the sandy environment and prevention of sand re-ingestion are effective measures for the elimination of sand from the colon of horses with asymptomatic sand accumulations.

1 August 2019 in Pesquisa Veterinária Brasileira
Verified
Journal Article
Open access
PDF file
WSWildemberto A. Santos
Wildemberto A. Santos
MVMichel C. Vettorato
Michel C. Vettorato
JFJéssica L. Fogaça
Jéssica L. Fogaça
NMNayara M.G. Mazzante
Nayara M.G. Mazzante
FOFernanda G. Oliveira
Fernanda G. Oliveira
VMVânia Maria Vasconcelos Machado
Vânia Maria Vasconcelos Machado
The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: “baby” (1), “sobreano” (2) and “adult” (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.

1 July 2020 in Pesquisa Veterinária Brasileira
Verified
Journal Article
Open access
PDF file
JFJéssica L. Fogaça
Jéssica L. Fogaça
MCMaria Cristina R. Castiglioni
Maria Cristina R. Castiglioni
MVMichel C. Vettorato
Michel C. Vettorato
JSJeana P. Silva
Jeana P. Silva
LBLaís M.C. Bueno
Laís M.C. Bueno
VMVânia Maria Vasconcelos Machado
Vânia Maria Vasconcelos Machado
In ultrasonography, the bi-dimensional mode (B-mode) allows the morphological and morphometric evaluation of several types of organs and tissues, while the Doppler mode allows the hemodynamic evaluation. In humans, the Doppler evaluation is routinely used in the assessment of important arteries and veins, such as the carotid arteries and jugular veins, with significant differences between genres and sides. However, in veterinary medicine, this diagnostic method is not yet well established in the evaluation of the carotid arteries, with only few reports in domestic horses. This study aims to compare the right and left common carotid arteries of domestic horses and mules using bi-dimensional and Doppler ultrasound evaluation. The common carotid arteries from 10 domestic horses (five males and five females) and 10 mules (five males and five females) were evaluated. The following variables were measured at three different portions (cranial, middle and caudal): diameter, intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV) and final diastolic velocity (fDV). No significant differences were observed in the bi-dimensional variables (diameter and IMT) between the common carotid arteries of horses and mules, regardless of gender (p>0.05). In Doppler mode, there were no significant differences between carotid values in male and female horses (p> 0.05). In the mules, it was only possible to observe differences between the RI and PI values (p<0.05), being higher on the left side (0.81 and 2.04 respectively), and the fDV (p<0.05) higher, on the right side (14.35) in males. As for females, there was only in fDV (p<0.05), with the upper right side (23.16). Diameters and IMT do not differ between sides in horses and mules in B-mode ultrasound. Spectral Doppler in horses does not differ between sides, regardless of gender. As for mules, males differ in RI, PI and fDV between sides, while females differ only in fDV.

1 July 2023 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Verified
Journal Article
Open access
PDF file
JFJ.L. Fogaça
J.L. Fogaça
MCM.C.R. Castiglioni
M.C.R. Castiglioni
MVM.C. Vettorato
M.C. Vettorato
GNG. B. Melo Neto
G. B. Melo Neto
GMG. M.N. Mazzante
G. M.N. Mazzante
VMVânia Maria Vasconcelos Machado
Vânia Maria Vasconcelos Machado
The present study aimed to evaluate and compare the palmar and plantar digital arteries of 10 horses and 10 mules through B-mode and spectral Doppler ultrasound. Likewise, compare the plantar arteries of the pelvic limbs with the palmar arteries of the thoracic limbs, in addition to verifying the differences of the digital arteries in the contralateral limbs (right and left) in horses and mules using B-mode and spectral Doppler ultrasonography. The evaluated parameters were the diameter and the intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV), final diastolic velocity (fDV) and mean velocity (MV) of the lateral and medial palmar and plantar arteries digital in healthy horses and mules. The horses presented higher diameters values, IMT, pSV, fDV and MV in comparison to the mules. The variables RI and PI also presented differences between horses and mules. Also, both species showed higher values in the variables of B-mode and Doppler ultrasonography in the thoracic limbs. Differences were also detected in the comparison between the limb sides (right and left) in the two modalities. The B-Mode and spectral Doppler ultrasound techniques are viable tools to identify differences in the palmar and plantar digital arteries in healthy horses and mules, highlight the differences between the thoracic and pelvic limbs and their respective sides (right and left) as well.

1 March 2019 in Pesquisa Veterinária Brasileira
Verified
Journal Article
Open access
PDF file
JFJéssica L. Fogaça
Jéssica L. Fogaça
MVMichel C. Vettorato
Michel C. Vettorato
JPJosé Nicolau P. Puoli-Filho
José Nicolau P. Puoli-Filho
MFMarco A.R. Fernandes
Marco A.R. Fernandes
VMVânia Maria Vasconcelos Machado
Vânia Maria Vasconcelos Machado
Visual inspection of ultrasound examination for assessment of echogenicity and echotexture of blood vessel tissues is a technique routinely used in medical practice in humans. However, simple visual inspection can lead to poor quality diagnoses and errors. The use of grayscale histogram (GSH) analysis has proved to be an efficient technique to quantify the region of interest, allowing minimization of image interpretation errors. This study aimed to evaluate and compare the echogenicity and echotexture of the walls of the common carotid arteries of healthy female horses and mules using the GSH technique and correlate them with age, body mass, and vessel diameters. B-mode ultrasound examinations were performed in the left and right common carotid arteries in three regions (cranial, middle, and caudal) in 11 horses and 11 healthy mules. The GSH of the animals showed heterogeneous walls, but did not differentiate statistically between female horses and mules. The Mean variable of the middle right, middle left and caudal right sides showed differences, more significant in the mules. On the middle right side, the Min variable was different, higher in the mules. On the middle and caudal left side, the variables Max and Mode showed higher values in the mules. For the mules, the age factor presented negative correlation with the Mean, Mode,, Mode(Count), and Mode(Count)/Count(%) variables, and the body mass factor presented negative correlation with the Mode, Mean and Max variables. For the female horses, the body mass factor showed positive correlation with the Mean and Mode variables. Echogenicity of the carotid artery walls differed between female horses and mules, whereas echotexture was heterogeneous and statistically similar among the animals. The age and body mass factors inversely influenced the echogenicity of the mules, but were not significant in the female horses, in which only the body mass factor positively influenced echogenicity.

1 January 2019 in Pesquisa Veterinária Brasileira
Verified
Journal Article
Open access
PDF file
JFJéssica L. Fogaça
Jéssica L. Fogaça
MCMaria C.R. Castiglioni
Maria C.R. Castiglioni
MVMichel C. Vettorato
Michel C. Vettorato
DADanilo Andrade
Danilo Andrade
JPJosé N.P. Puoli-Filho
José N.P. Puoli-Filho
VMVânia Maria Vasconcelos Machado
Vânia Maria Vasconcelos Machado
As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.