Göran Engdahl

Göran Engdahl

Auto-generated profile, based on publicly available information

Göran Engdahl

Royal Institute of Technology Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2000
Verified
Book Chapter
Closed access
GEGöran Engdahl
Göran Engdahl

8 December 2015 in Actuators
Verified
Journal Article
Open access
PDF file
ABAra Bissal
Ara Bissal
AEAnders Eriksson
Anders Eriksson
JMJesper Magnusson
Jesper Magnusson
GEGöran Engdahl
Göran Engdahl
The challenges of an HVDC breaker are to generate impulsive forces in the order of hundreds of kilonewtons within fractions of a millisecond, to withstand the arising internal mechanical stresses and to transmit these forces via an electrically-insulating device to the contact system with minimum time delay. In this work, several models were developed with different levels of complexity, computation time and accuracy. Experiments were done with two mushroom-shaped armatures to validate the developed simulation models. It was concluded that although the electromagnetic force generation mechanism is highly sensitive to the mechanical response of the system, the developed first order hybrid model is able to predict the performance of the breaker with good accuracy.

6 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MPMrunal Parekh
Mrunal Parekh
JMJesper Magnusson
Jesper Magnusson
GEGoran Engdahl
Goran Engdahl
MBMarley Becerra
Marley Becerra
A mechanical switch can be used instead of a power electronic load commutation switch in orderto reduce the losses during normal power flow in standard hybrid DC circuit breakers. The success of current commutation in such hybrid breakers depends on the arc voltage formed across the contacts in the mechanical switch. The behaviour of rapidly elongated, wall constricted arcsgenerated during the opening of an ultra-fast mechanical switch in the air is studied here. The voltage-current characteristics of the generated arcs are obtained for steady state contact opening velocities of 6, 11 and 21 m/s. It is found that the arc voltage at a given current and contact separation increases with the contact opening velocity. It is shown that stationary,zero-contact-velocity characteristics can not be used to accurately quantify the voltage build-up in fast elongating arcs in hybrid breakers. A best-fitting black-box equation for the dynamic arc characteristics is presented for the tested velocities. The obtained voltage-current characteristics are used as input to simulate the current commutation process in a 12 kV hybridDC circuit breaker case-study. Different scenarios of current commutation failure related to the arc voltage build up are identified. It is shown that these failures scenarios can be avoided by increasing the contact opening velocity.

1 January 2000
Verified
Book Chapter
Closed access
GEGöran Engdahl
Göran Engdahl
CBCharles B. Bright
Charles B. Bright

25 September 2006 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
DRD. Ribbenfjard
D. Ribbenfjard
GEG. Engdahl
G. Engdahl
This work presents a dynamic hysteresis model based on Bergqvist's lag model for static hysteresis and Bertotti's model for dynamic hysteresis. This new model is used for simulation of magnetic materials. The simulation results are compared with measurements of the amorphous alloy Metglas 2605 S-2 and the transformer steel Surahammar M5. The simulated results show good agreement with the measurements