Enhanced active resonant (EAR) dc circuit breakers (DCCBs) are a promising set of recently proposed DCCB concepts. As other DCCBs, EAR DCCBs still require a fast mechanical switch. The requirements on the actuator of the mechanical switch depend on the DCCB concept and the dc grid and are derived here for an EAR DCCB. Thomson-coil actuators (TCAs) can open and close mechanical switches sufficiently fast to satisfy the requirements. This work studies experimentally a TCA system with active damping for an off-the-shelf industrial vacuum interrupter used as mechanical switch in an EAR DCCB. The prototype is explained in detail, and extensive measurement results are presented, showing that active damping must be perfectly timed to be effective. A novel Thomson-coil (TC) driver is proposed and studied experimentally, which operates the TCA more efficiently by recycling energy during the actuation. Moreover, the novel TC driver reduces the capacitive storage by 50% and allows for faster recharging with lower charging current. Finally, the autoreclosing and proactive commutation operation of the TCA system and the interruption capability of the prototype EAR DCCB are demonstrated experimentally.
Measurements of medium and high voltages in a power grid are normally performed with large and bulky voltage transformers or capacitive dividers. Besides installation problems, these devices operate in a relatively narrow frequency band, which limits their usability in modern systems that are saturated with power electronic devices. A sensor that can be installed directly on a wire and can operate without a galvanic connection to the ground may be used as an alternative voltage measurement device. This type of voltage sensor can complement current sensors installed on a wire, forming a complete power acquisition system. This paper presents such a sensor. Our sensor is built using two dielectric elements with different permeability coefficients. A finite element method simulation is used to estimate the parameters of a constructed sensor. Besides simulations, a laboratory model of a sensor was built and tested in a medium-voltage substation. Our results provide a proof of concept for the presented sensor. Some errors in voltage reconstruction have been traced to an oversimplified data acquisition and transmission system, which has to be improved during the further development of the sensor.
4 September 2012 in IEEE Transactions on Plasma Science
This paper discusses the modeling of a peaking switch to study the reduction in rise time for the subnanosecond duration pulses. The effect of the various shapes of input pulse, inductance, and interelectrode distance on the output voltage and wave shape is discussed in this paper. The modeling has been carried out using the electromagnetic and microwave modeling software of Computer Simulation Technology.
6 October 2020 in IEEE Transactions on Power Delivery
A mechanical switch can be used instead of a power electronic load commutation switch in orderto reduce the losses during normal power flow in standard hybrid DC circuit breakers. The success of current commutation in such hybrid breakers depends on the arc voltage formed across the contacts in the mechanical switch. The behaviour of rapidly elongated, wall constricted arcsgenerated during the opening of an ultra-fast mechanical switch in the air is studied here. The voltage-current characteristics of the generated arcs are obtained for steady state contact opening velocities of 6, 11 and 21 m/s. It is found that the arc voltage at a given current and contact separation increases with the contact opening velocity. It is shown that stationary,zero-contact-velocity characteristics can not be used to accurately quantify the voltage build-up in fast elongating arcs in hybrid breakers. A best-fitting black-box equation for the dynamic arc characteristics is presented for the tested velocities. The obtained voltage-current characteristics are used as input to simulate the current commutation process in a 12 kV hybridDC circuit breaker case-study. Different scenarios of current commutation failure related to the arc voltage build up are identified. It is shown that these failures scenarios can be avoided by increasing the contact opening velocity.
One of the major challenges of DC circuit breakers is the required fast mechanical actuator. In this paper, a Thomson coil actuator system for a vacuum interrupter is designed. Active damping is used to decelerate the moving contacts. Challenges are discussed, especially concerning the power supply needed for the Thomson coil actuator. The design philosophy is explained and FEM simulation results are presented. The results indicate that a wide range of combinations of drive circuit capacitance and voltage fulfill the requirements for armature acceleration. However, active damping requires a very careful selection of drive circuit voltage and timing of applied damping.
1 February 2019 in International Journal of Applied Electromagnetics and Mechanics
Ultra-fast circuit breakers are operated with fast electromagnetic actuators. They can generate a sufficient impulse force to swiftly open electrical contacts in a couple of milliseconds. Opening of the contacts with high velocities implies a need for a timely and controllable damping. An efficient damping mechanism then is crucial to attain an appropriate actuation performance and secure a long lifetime. In this paper a finite element model of a Halbach magnet array based magnetic damper and a corresponding experimental prototype is described. A parametric study is performed to understand the effect of load mass and incoming velocities. It was found that the magnetic field modulation plays an important role on the damping performance. A uniform and high radial component of the magnetic flux density is necessary in order to achieve high damping force. The radial magnetic field can be controlled via thickness and magnetization direction of the ring magnets that are used to create the Halbach magnet array.