Kenneth J. Faber

Kenneth J. Faber

Auto-generated profile, based on publicly available information

Kenneth J. Faber

McFarlane Hand and Upper Limb Centre, Lawson Health Research Institute, London, Canada

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
RGRuby Grewal
Ruby Grewal
GAGeorge S. Athwal
George S. Athwal
JMJoy C. MacDermid
Joy C. MacDermid
KFKenneth J. Faber
Kenneth J. Faber
DDDarren S. Drosdowech
Darren S. Drosdowech
GKGraham J.W. King
Graham J.W. King
Background: This clinical trial was done to evaluate outcomes of the single and double-incision techniques for acute distal biceps tendon repair. We hypothesized that there would be fewer complications and less short-term pain and disability in the two-incision group, with no measureable differences in outcome at a minimum of one year postoperatively. Methods: Patients with an acute distal biceps rupture were randomized to either a single-incision repair with use of two suture anchors (n = 47) or a double-incision repair with use of transosseous drill holes (n = 44). Patients were followed at three, six, twelve, and twenty-four months postoperatively. The primary outcome was the American Shoulder and Elbow Surgeons (ASES) elbow score. Secondary outcomes included muscle strength, complication rates, and Disabilities of the Arm, Shoulder and Hand (DASH) and Patient-Rated Elbow Evaluation (PREE) scores. Results: All patients were male, with no significant differences in the mean age, percentages of dominant hands affected, or Workers’ Compensation cases between groups. There were also no differences in the final outcomes (at two years) between the two groups (p = 0.4 for ASES pain score, p = 0.10 for ASES function score, p = 0.3 for DASH score, and p = 0.4 for PREE score). In addition, there were no differences in isometric extension, pronation, or supination strength at more than one year. A 10% advantage in final isometric flexion strength was seen in the patients treated with the double-incision technique (104% versus 94% in the single-incision group; p = 0.01). There were no differences in the rate of strength recovery. The single-incision technique was associated with more early transient neurapraxias of the lateral antebrachial cutaneous nerve (nineteen of forty-seven versus three of forty-three in the double-incision group, p < 0.001). There were four reruptures, all of which were related to patient noncompliance or reinjury during the early postoperative period and appeared to be unrelated to the fixation technique (p = 0.3). Conclusions: There were no significant differences in outcomes between the single and double-incision distal biceps repair techniques other than a 10% advantage in final flexion strength with the latter. Most complications were minor, with a significantly greater prevalence in the single-incision group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 October 2006 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
RGRuby Grewal
Ruby Grewal
JMJoy C. MacDermid
Joy C. MacDermid
KFKenneth J. Faber
Kenneth J. Faber
DDDarren S. Drosdowech
Darren S. Drosdowech
GKGraham J.W. King
Graham J.W. King
Background: Comminuted fractures of the radial head are challenging to treat with open reduction and internal fixation. Radial head arthroplasty is an alternative treatment with results that compare favorably with those reported after open reduction and internal fixation of similar fractures. The purpose of this study was to evaluate the two-year outcomes and the rate of recovery of a closely followed cohort of patients in whom an unreconstructible radial head fracture had been treated with a modular metallic prosthesis. Methods: Twenty-six patients (seventeen female and nine male; mean age, fifty-four years) with an unreconstructible comminuted radial head fracture and associated elbow injuries were treated with a modular metallic radial head arthroplasty. Patients who had presented more than four weeks following the injury or had had the radial head arthroplasty as a second-stage or salvage procedure were excluded. Of the twenty-six patients, twenty-two had an associated elbow dislocation, and thirteen of them also had an associated fracture of the coronoid process. Patients were prospectively followed at three, six, twelve, and twenty-four months. Self-reported limb function, general health, range of motion, and isometric strength were assessed by an independent observer. Results: Following treatment of the injury, significant decreases in self-reported and measured impairments were noted over time, with the majority of the recovery occurring by six months and little further recovery noted between six and twenty-four months. There were slight-to-moderate deficits in the range of motion and strength compared with the values on the contralateral, unaffected side. Patient satisfaction was high at three months and remained high at two years. All elbow joints remained stable, no implant required revision, and there was no evidence of overstuffing of the joint. Mild osteoarthritis was seen in five (19%) of the twenty-six patients. Conclusions: An arthroplasty with a modular metallic radial head is a safe and effective option for the treatment of unreconstructible radial head fractures associated with other elbow injuries. Recovery primarily occurs by six months, with minimal additional improvements over the next eighteen months. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

1 February 2008 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
BSBenjamin J. Shore
Benjamin J. Shore
JMJeremy B. Mozzon
Jeremy B. Mozzon
JMJoy C. MacDermid
Joy C. MacDermid
KFKenneth J. Faber
Kenneth J. Faber
GKGraham J.W. King
Graham J.W. King
Background: Metallic radial head arthroplasty is a proven technique for the treatment of complex radial head fractures. The purpose of this study was to evaluate the functional outcomes of a metallic radial head arthroplasty in patients with chronic posttraumatic elbow disorders. Methods: The results of thirty-two metallic radial head arthroplasties in thirty-two consecutive patients were retrospectively reviewed. The indications for the radial head arthroplasty included posttraumatic nonunion and malunion of the radial head, elbow instability following previous excision of the radial head, and failure of a silicone radial head implant used to treat an acute radial head fracture. The study included thirteen male and nineteen female patients followed for a minimum of two years. The radial head arthroplasties were performed at an average of 2.4 years after the injury. Analysis included chart review, personal interview, physical examination, radiographic examination, and strength testing as well as the administration of general and region-specific questionnaires. Results: The mean duration of follow-up was eight years. The average Mayo Elbow Performance Score was 83 of 100 points, with seventeen (53%) of the thirty-two results rated as excellent; four (13%), as good; seven (22%), as fair; and four (13%), as poor. The average score for subjective patient satisfaction was 8.5 points on a 10-point scale. Patients had significantly less motion and strength in the affected elbow than in the unaffected elbow. Seventy-four percent of the patients demonstrated some degree of posttraumatic arthritis. There were no significant differences in ulnar variance and the ulnohumeral joint space between the affected and unaffected arms. Over the course of the study, no metallic radial head arthroplasties required revision. Conclusions: Metallic radial head arthroplasty for the treatment of posttraumatic elbow disorders appears to be a safe and durable procedure that can provide a functional range of motion and pain relief for at least five to ten years. However, longer follow-up is needed to evaluate progression of lucencies adjacent to stems and osteoarthritis. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

16 March 2016 in Current Reviews in Musculoskeletal Medicine
Verified
Journal Article
Closed access
PDF file
KCKevin Chan
Kevin Chan
GKGraham J. W. King
Graham J. W. King
KFKenneth J. Faber
Kenneth J. Faber

7 June 2011 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
RGRuby Grewal
Ruby Grewal
JAJoseph Assini
Joseph Assini
DSDavid Sauder
David Sauder
LFLouis Ferreira
Louis Ferreira
JJJim Johnson
Jim Johnson
KFKenneth Faber
Kenneth Faber
Purpose: The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw.Methods: Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed under fluoroscopic control using the manufacturer's recommended surgical technique. Compressive forces were measured during screw insertion. Recording continued for an additional 60s in order to measure any loss of compression after installation was complete. The peak and final interfragmentary compression were recorded and paired t-tests performed.Results: The mean peak compression generated by the Acutrak 2 Standard was greater than that produced by the Synthes compression screw (103.9 ± 33.2 N vs. 88.7 ± 38.6 N respectively, p = 0.13). The mean final interfragmentary compression generated by the Acutrak 2 screw (68.6 ± 36.4 N) was significantly greater (p = 0.04) than the Synthes screw (37.2 ± 26.8 N). Specimens typically reached a steady state of compression by 120-150s after final tightening.Conclusion: Peak interfragmentary compression observed during screw installation was similar for both screw systems. However, the mean interfragmentary compression generated by the Acutrak 2 Standard was significantly greater. Our study demonstrates that the Synthes headless compression screw experienced a greater loss of interfragmentary compressive force from the time of installation to the final steady state compression level. The higher post-installation compression of the Acutrak 2 Standard may be attributable to the greater number of threads throughout the entire length of the screw. The clinical significance of these results, are, at this point uncertain. We do demonstrate that a fully threaded design offers a more reliable compression that may translate to more predictable bony union.

16 July 2003 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JHJeffrey C Howard
Jeffrey C Howard
VVVincenzo M Varallo
Vincenzo M Varallo
DRDouglas C Ross
Douglas C Ross
JRJames H Roth
James H Roth
KFKenneth J Faber
Kenneth J Faber
BGBing Siang Gan
Bing Siang Gan
Dupuytren's contracture or disease (DD) is a fibro-proliferative disease of the hand that results in the development of scar-like, collagen-rich disease cords within specific palmar fascia bands. Although the molecular pathology of DD is unknown, recent evidence suggests that β-catenin may play a role. In this study, collagen matrix cultures of primary disease fibroblasts show enhanced contraction and isometric tension-dependent changes in β-catenin and fibronectin levels. Western blots of β-catenin and fibronectin levels were determined for control and disease primary cell cultures grown within stressed- and attached-collagen matrices. Collagen contraction was quantified, and immunocytochemistry analysis of filamentous actin performed. Disease cells exhibited enhanced collagen contraction activity compared to control cells. Alterations in isometric tension of collagen matrices triggered dramatic changes in β-catenin and fibronectin levels, including a transient increase in β-catenin levels within disease cells, while fibronectin levels steadily decreased to levels below those seen in normal cell cultures. In contrast, both fibronectin and β-catenin levels increased in attached collagen-matrix cultures of disease cells, while control cultures showed only increases in fibronectin levels. Immunocytochemistry analysis also revealed extensive filamentous actin networks in disease cells, and enhanced attachment and spreading of disease cell in collagen matrices. Three-dimensional collagen matrix cultures of primary disease cell lines are more contractile and express a more extensive filamentous actin network than patient-matched control cultures. The elevated levels of β-catenin and Fn seen in collagen matrix cultures of disease fibroblasts can be regulated by changes in isometric tension.