Francesco D'ANtonio

Francesco D'ANtonio

Auto-generated profile, based on publicly available information

Francesco D'ANtonio

Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, UK

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
FDFrancesco D'ANtonio
Francesco D'ANtonio
SWShaun Warrington
Shaun Warrington
JMJose‐Pedro Manzano‐Patron
Jose‐Pedro Manzano‐Patron
PMPaul S. Morgan
Paul S. Morgan
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Purpose: Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare's AIR‐Recon DL (ARDL), a proprietary convolutional neural network‐based reconstruction and denoising approach, to patch‐based MPPCA SVS and NORDIC denoising methods on high‐resolution dMRI data. Methods: We developed an end‐to‐end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCA SVS , NORDIC, and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the signal profiles in highly anisotropic areas, and secondary downstream measurements, such as fiber orientation estimation and white matter tractography. Results: Our validated offline reconstruction supports various in‐plane/out‐of‐plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared with magnitude‐constrained denoising. PCA‐based denoising methods had improved spatial resolution, contrast‐to‐noise and more robust fiber orientation estimation compared with ARDL. Conclusion: We found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex‐domain denoising to obtain high‐quality data at high spatial resolution and b‐value, using a wide‐bore scanner and a standard PGSE EPI sequence. MPPCA SVS and NORDIC (4D PCA‐based) outperformed ARDL (2D) in terms of spatial resolution and reduction of noise variance.

7 November 2025 in bioRxiv
Verified
Preprint
Open access
FDFrancesco D’ANtonio
Francesco D’ANtonio
SWShaun Warrington
Shaun Warrington
JMJose-Pedro Manzano-Patron
Jose-Pedro Manzano-Patron
PMPaul S. Morgan
Paul S. Morgan
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Purpose: Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare’s AIR-Recon DL™ (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to open-source PCA-based MPPCA SVS and NORDIC denoising methods on high-resolution dMRI data. Methods: We developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCA SVS , NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the ADC profiles in highly anisotropic areas, and downstream measurements, such as fiber orientation estimation and white matter tractography. Results: Our validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL. Conclusion: We found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCA SVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution, reduction of noise-floor bias and variance.

13 October 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
JHJenna M. Hanmer
Jenna M. Hanmer
FDFrancesco D’ANtonio
Francesco D’ANtonio
SAStephania Assimopoulos
Stephania Assimopoulos
JMJose-Pedro Manzano-Patron
Jose-Pedro Manzano-Patron
SWSydney C. Wood
Sydney C. Wood
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Whole-brain cellular mapping is essential for understanding how differences in cellular architecture shape brain organisation and function. Magnetic Resonance Imaging (MRI) provides whole-brain coverage in humans and animal models but is only indirectly sensitive to cellular features. Integrating MRI with whole-brain microscopy is therefore critical for interpreting existing microstructural MRI measures and developing more specific ones. Here, we present a scalable cross-resolution framework integrating 3D light-sheet microscopy (LSM) of intact rodent brains with diffusion MRI (dMRI). By combining active tissue clearing and immunolabelling with accelerated LSM acquisitions, we achieve multiplexed whole-brain mapping of neuronal and glial populations on timescales comparable to conventional histology and 2D microscopy. This throughput enables LSM and MRI integration at scale, linking macroscopic MRI contrasts to spatially-matched microscopic cellular features within the same tissue. We apply this framework across eight genetically diverse mouse strains to develop predictive models of 3D microscopy-derived cellular features from dMRI contrasts. We demonstrate that data-driven combinations of state-of-the-art multi-shell dMRI measures predict neuronal and astrocytic features better than individual contrasts, across all animals. Our approach enables 3D microscopy to guide the development and interpretation of biologically-specific microstructural MRI measures, with the potential for translation to the living human brain.