Jose-Pedro Manzano-Patron

Jose-Pedro Manzano-Patron

Auto-generated profile, based on publicly available information

Jose-Pedro Manzano-Patron

Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, UK

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
SPStefan Pszczolkowski
Stefan Pszczolkowski
JMJosé P. Manzano-Patrón
José P. Manzano-Patrón
ZLZHE KANG LAW
ZHE KANG LAW
KKKailash Krishnan
Kailash Krishnan
AAAzlinawati Ali
Azlinawati Ali
RDRob A. Dineen
Rob A. Dineen
Objectives: To test radiomics-based features extracted from noncontrast CT of patients with spontaneous intracerebral haemorrhage for prediction of haematoma expansion and poor functional outcome and compare them with radiological signs and clinical factors. Materials and methods: Seven hundred fifty-four radiomics-based features were extracted from 1732 scans derived from the TICH-2 multicentre clinical trial. Features were harmonised and a correlation-based feature selection was applied. Different elastic-net parameterisations were tested to assess the predictive performance of the selected radiomics-based features using grid optimisation. For comparison, the same procedure was run using radiological signs and clinical factors separately. Models trained with radiomics-based features combined with radiological signs or clinical factors were tested. Predictive performance was evaluated using the area under the receiver operating characteristic curve (AUC) score. Results: The optimal radiomics-based model showed an AUC of 0.693 for haematoma expansion and an AUC of 0.783 for poor functional outcome. Models with radiological signs alone yielded substantial reductions in sensitivity. Combining radiomics-based features and radiological signs did not provide any improvement over radiomics-based features alone. Models with clinical factors had similar performance compared to using radiomics-based features, albeit with low sensitivity for haematoma expansion. Performance of radiomics-based features was boosted by incorporating clinical factors, with time from onset to scan and age being the most important contributors for haematoma expansion and poor functional outcome prediction, respectively. Conclusion: Radiomics-based features perform better than radiological signs and similarly to clinical factors on the prediction of haematoma expansion and poor functional outcome. Moreover, combining radiomics-based features with clinical factors improves their performance. Key Points: • Linear models based on CT radiomics-based features perform better than radiological signs on the prediction of haematoma expansion and poor functional outcome in the context of intracerebral haemorrhage. • Linear models based on CT radiomics-based features perform similarly to clinical factors known to be good predictors. However, combining these clinical factors with radiomics-based features increases their predictive performance.

20 April 2025 in Medical Image Analysis
Verified
Journal Article
Open access
JMJ.P. Manzano-Patrón
J.P. Manzano-Patrón
MDMichael Deistler
Michael Deistler
CSCornelius Schröder
Cornelius Schröder
TKTheodore Kypraios
Theodore Kypraios
PGPedro J. Gonçalves
Pedro J. Gonçalves
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Simulation-Based Inference (SBI) has recently emerged as a powerful framework for Bayesian inference: Neural networks are trained on simulations from a forward model, and learn to rapidly estimate posterior distributions. We here present an SBI framework for parametric spherical deconvolution of diffusion MRI data of the brain. We demonstrate its utility for estimating white matter fibre orientations, mapping uncertainty of voxel-based estimates and performing probabilistic tractography by spatially propagating fibre orientation uncertainty. We conduct an extensive comparison against established Bayesian methods based on Markov-Chain Monte-Carlo (MCMC) and find that: a) in-silico training can lead to calibrated SBI networks with accurate parameter estimates and uncertainty mapping for both single- and multi-shell diffusion MRI, b) SBI allows amortised inference of the posterior distribution of model parameters given unseen observations, which is orders of magnitude faster than MCMC, c) SBI-based tractography yields reconstructions that have a high level of agreement with their MCMC-based counterparts, equal to or higher than scan-rescan reproducibility of estimates. We further demonstrate how SBI design considerations (such as dealing with noise, defining priors and handling model selection) can affect performance, allowing us to identify optimal practices. Taken together, our results show that SBI provides a powerful alternative to classical Bayesian inference approaches for fast and accurate model estimation and uncertainty mapping in MRI.

20 April 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
RBR. Austin Benn
R. Austin Benn
TXTing Xu
Ting Xu
RMRogier B. Mars
Rogier B. Mars
MBMagdalena Boch
Magdalena Boch
LRLea Roumazeilles
Lea Roumazeilles
BIBorja Ibanez
Borja Ibanez
Cortical surface reconstruction has transformed the study of brain morphology and cortical geometry in human neuroimaging. Here we present precon_all, an open-source structural imaging pipeline that generalizes reconstruction of the neocortical surface to multiple species. Adopting a modular framework that mirrors FreeSurfer’s recon-all in humans, precon_all produces surfaces for non-human species compatible with FreeSurfer and Connectome Workbench. Precon_all reduces the dependencies of surface reconstruction to an image with T1-like contrast and five user-defined masks. This removes the dependence on species-specific atlases and tissue priors, and in turn extends surface reconstruction to species where these resources do not yet exist. The pipeline supports a wide range of imaging conditions, including in-vivo and post-mortem data, and has thus far been used to reconstruct the cortical geometry of primates, carnivores, and ungulates across multiple sites, spanning both highly gyrified and lissencephalic brains. Precon_all can be automated for high-throughput processing, and its template construction module can build surface-based common spaces to enable group-level analysis of cortical morphometry in new species. In short, precon_all is a flexible, modular pipeline that enables the comparative neuroimaging community to study brain evolution through cortical geometry in an ever-growing number of species.

26 July 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
JMJose-Pedro Manzano-Patron
Jose-Pedro Manzano-Patron
SMSteen Moeller
Steen Moeller
JAJesper L.R. Andersson
Jesper L.R. Andersson
KUKamil Ugurbil
Kamil Ugurbil
EYEssa Yacoub
Essa Yacoub
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Development of diffusion MRI (dMRI) denoising approaches has experienced considerable growth over the last years. As noise can inherently reduce accuracy and precision in measurements, its effects have been well characterised both in terms of uncertainty increase in dMRI-derived features and in terms of biases caused by the noise floor, the smallest measurable signal given the noise level. However, gaps in our knowledge still exist in objectively characterising dMRI denoising approaches in terms of both of these effects and assessing their efficacy. In this work, we reconsider what a denoising method should and should not do and we accordingly define criteria to characterise the performance. We propose a comprehensive set of evaluations, including i) benefits in improving signal quality and reducing noise variance, ii) gains in reducing biases and the noise floor and improving, iii) preservation of spatial resolution, iv) agreement of denoised data against a gold standard, v) gains in downstream parameter estimation (precision and accuracy), vi) efficacy in enabling noise-prone applications, such as ultra-high-resolution imaging. We further provide newly acquired complex datasets (magnitude and phase) with multiple repeats that sample different SNR regimes to highlight performance differences under different scenarios. Without loss of generality, we subsequently apply a number of exemplar patch-based denoising algorithms to these datasets, including Non-Local Means, Marchenko-Pastur PCA (MPPCA) in the magnitude and complex domain and NORDIC, and compare them with respect to the above criteria and against a gold standard complex average of multiple repeats. We demonstrate that all tested denoising approaches reduce noise-related variance, but not always biases from the elevated noise floor. They all induce a spatial resolution penalty, but its extent can vary depending on the method and the implementation. Some denoising approaches agree with the gold standard more than others and we demonstrate challenges in even defining such a standard. Overall, we show that dMRI denoising performed in the complex domain is advantageous to magnitude domain denoising with respect to all the above criteria.

19 November 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
JMJ.P. Manzano-Patron
J.P. Manzano-Patron
MDMichael Deistler
Michael Deistler
CSCornelius Schröder
Cornelius Schröder
TKTheodore Kypraios
Theodore Kypraios
PGPedro J. Gonçalves
Pedro J. Gonçalves
SSStamatios S.N. Sotiropoulos
Stamatios S.N. Sotiropoulos
Simulation-Based Inference (SBI) has recently emerged as a powerful framework for Bayesian inference: Neural networks are trained on simulations from a forward model, and learn to rapidly estimate posterior distributions. We here present an SBI framework for parametric spherical deconvolution of diffusion MRI data of the brain. We demonstrate its utility for estimating white matter fibre orientations, mapping uncertainty of voxel-based estimates and performing probabilistic tractography by spatially propagating fibre orientation uncertainty. We conduct an extensive comparison against established Bayesian methods based on Markov-Chain Monte-Carlo (MCMC) and find that: a) in-silico training can lead to calibrated SBI networks with accurate parameter estimates and uncertainty mapping for both single- and multi-shell diffusion MRI, b) SBI allows amortised inference of the posterior distribution of model parameters given unseen observations, which is orders of magnitude faster than MCMC, c) SBI-based tractography yields reconstructions that have a high level of agreement with their MCMC-based counterparts, equal to or higher than scan-rescan reproducibility of estimates. We further demonstrate how SBI design considerations (such as dealing with noise, defining priors and handling model selection) can affect performance, allowing us to identify optimal practices. Taken together, our results show that SBI provides a powerful alternative to classical Bayesian inference approaches for fast and accurate model estimation and uncertainty mapping in MRI.

7 March 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
FDFrancesco D'ANtonio
Francesco D'ANtonio
SWShaun Warrington
Shaun Warrington
JMJose‐Pedro Manzano‐Patron
Jose‐Pedro Manzano‐Patron
PMPaul S. Morgan
Paul S. Morgan
SSStamatios N. Sotiropoulos
Stamatios N. Sotiropoulos
Purpose: Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare's AIR‐Recon DL (ARDL), a proprietary convolutional neural network‐based reconstruction and denoising approach, to patch‐based MPPCA SVS and NORDIC denoising methods on high‐resolution dMRI data. Methods: We developed an end‐to‐end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCA SVS , NORDIC, and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the signal profiles in highly anisotropic areas, and secondary downstream measurements, such as fiber orientation estimation and white matter tractography. Results: Our validated offline reconstruction supports various in‐plane/out‐of‐plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared with magnitude‐constrained denoising. PCA‐based denoising methods had improved spatial resolution, contrast‐to‐noise and more robust fiber orientation estimation compared with ARDL. Conclusion: We found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex‐domain denoising to obtain high‐quality data at high spatial resolution and b‐value, using a wide‐bore scanner and a standard PGSE EPI sequence. MPPCA SVS and NORDIC (4D PCA‐based) outperformed ARDL (2D) in terms of spatial resolution and reduction of noise variance.