A failure of insulation is one of the main reasons for electric machine outage. Online condition monitoring (CM) of an incipient degradation of turn insulation could eliminate the potential fault at the early stage, which is attractive but challenging. To improve the sensitivity and availability of CM, a noninvasive technique is presented in this article for the inverter-fed electric machine utilizing the existing high-frequency (HF) switching oscillations during pulsewidth modulation operation. First, the tail component sensitive to turn insulation is selected among the dominant oscillation modes in switching current, which can penetrate the winding of machine within an adequate frequency band (e.g., several hundreds of kHz). Then, a noncontact and simple HF sensor is developed for switching oscillation current capture. The CM system, procedure, and turn insulation state indicator are devised. After that, experimental work is carried out on a 3-kW permanent magnet synchronous machine test rig. The results show good sensitivity (about 2%) to the local incipient degradation of turn insulation with insusceptibility to the operating conditions. Finally, further discussion is given to demonstrate the performance of the method.
3 December 2020 in IEEE Transactions on Power Electronics
Online monitoring of DC-link capacitor's equivalent series resistance (ESR) could provide valuable and timely information for power converter failure prognosis and predictive maintenance. The conventional ESR estimation methods are mainly based on PWM voltage and current ripples (ESR∼δuc/δic), but the performance is affected by operating conditions (especially at light-load), quasi-resonance effect and sensor amplitude error. To overcome these difficulties, an online ESR monitoring method is proposed using the damping characteristic of DC capacitor switching ringings. The intrinsic high-frequency (HF) resonance incidents between the power device fast switching and converter parasitic parameters are utilized in this paper. First, the mechanism of DC capacitor switching ringing is analyzed by the HF resonance equivalent circuit. The analytic relationship between the damping characteristic and the ESR is established. Then, the condition monitoring (CM) scheme, non-contact HF sensor, and half-power bandwidth algorithm for ESR estimation are presented. Finally, an experimental study is carried out to validate the feasibility and effectiveness. The damping of switching ringing is inherently sensitive to the ESR of DC capacitor under the condition of resonance. Both theoretical analysis and experimental results confirm that the proposed method can achieve mφ-level accuracy and good robustness under different conditions.
1 April 2021 in IEEE Transactions on Power Electronics
Turn- off time is an important condition parameter for insulated gate bipolar transistor (IGBT), which could provide useful information on the device junction temperature and its state of health. Currently, it is measured directly from the IGBT collector-emitter voltage V ce or indirectly from the gate side, which may cause problems of safety and complexity for a power converter operating in a harsh electromagnetic environment. To address the challenges, this article proposes a noncontact method to monitor the IGBT turn- off time from the PWM switching ringing in the converter output current. First, a phenomenon is observed that there are two switch-over points in the switching ringing current corresponding to the transition of IGBT turn- off voltage. Analytical analysis is performed with a high-frequency (HF) equivalent circuit to investigate the mechanism of the one-to-one temporal relationship. Then, the noncontact condition monitoring (CM) scheme including the HF switching ringing current sensor and the framework of CM system is devised. Finally, experimental work is carried out to validate the theoretical analysis and the effectiveness of the method. Research results show that the turn- off time of multi-IGBTs can be effectively extracted at the terminal of converter during system normal operation with electrically isolated safety.