David de Oliveira Cerveira

David de Oliveira Cerveira

Auto-generated profile, based on publicly available information

David de Oliveira Cerveira

Universidade Feevale

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
SKSandra Raquel Kunst
Sandra Raquel Kunst
DCDavid de Oliveira Cerveira
David de Oliveira Cerveira
JFJane Zoppas Ferreira
Jane Zoppas Ferreira
TGThaís Francine Graef
Thaís Francine Graef
JSJoseane de Andrade Santana
Joseane de Andrade Santana
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
Titanium has been widely used as biomaterial, especially in implantables, in which osseointegration and corrosion resistance are needed. Studies have shown that the thickness and roughness of porous titanium oxides are related to the osseointegration. According to the literature, the best anodizing conditions for obtaining nanotubes in titanium oxide are the use of a voltage of 10V in an electrolyte containing 0.15% HF in H3PO4 (w/v). In this study, was to evaluate the corrosion capacity of simulated body fluid (SBF) over titanium samples anodized on 1 mol. L-1 H3PO4 and 0.15% HF (w/v) in 1 mol.L-1 H3PO4. To perform these evaluations samples of commercially pure titanium grade 2 were used. Samples were analyzed by scanning electron microscopy, atomic force microscopy and by electrochemical corrosion tests in healthy and simulating inflammatory conditions. The hydrophobicity of oxides was tested by sessile drop essay, also using SBF. Results show that oxides obtained in H3PO4 electrolyte, barrier type oxides, work better than the porous oxides obtained in H3PO4/HF electrolyte, suggesting that barrier oxide exhibit more biomaterial characteristics than the porous oxide. These results agree with previous studies, and stand out mainly in relation to the tests performed under inflammatory conditions, more aggressive to the biomaterial.

5 September 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
DCDavid de Oliveira Cerveira
David de Oliveira Cerveira
SKSandra Raquel Kunst
Sandra Raquel Kunst
LMLuã Tainachi Mueller
Luã Tainachi Mueller
FMFernando Dal Pont Morisso
Fernando Dal Pont Morisso
AZAna Luiza Ziulkoski
Ana Luiza Ziulkoski
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
Psidium guajava, commonly known as 'guava', belongs to the Myrtaceae family and is an alternative to the use of traditional methods of corrosion inhibition. The aim of this study is to anodize titanium in an environmentally friendly Psidium guajava electrolyte in order to improve its anti-corrosion performance. For this purpose, samples of CP (commercially pure) titanium grade 2 were anodized in plant extract based on Psidium guajava, with transient variations of current density (1 and 0.1 mA/cm²) and time (5, 30 and 60 min). Samples were characterized in terms of morphology by SEM (Scanning Electron Microscopy) analysis. The hydrophobicity of oxides was evaluated by the sessile drop method. Anodized samples were analyzed for colorimetry by the CIE L*a*b* method and the electrolyte based on Psidium guajava was analyzed by UV-Vis and cyclic voltammetry, in order to understand the compounds and their behavior in the anodizing process. From the obtained results, the oxides generated through anodization at current density of 0.1 mA/cm² were the ones that presented the best performance. The results obtained at 5 and 30 minutes of anodizing showed very similar results and greater reproducibility compared to the others analyzed, which showed the formation of a barrier-type oxide layer in the samples. In the Psidium guajava electrolyte, it was evidenced the presence of phenolic groups in its composition, which is believed to influence the process of formation of the oxide layer in the anodization process.