Cláudia Trindade Oliveira

Cláudia Trindade Oliveira

Auto-generated profile, based on publicly available information

Cláudia Trindade Oliveira

Universidade Feevale, Brasil

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
LFLuciane Taís Fuhr
Luciane Taís Fuhr
ÂMÂngela Beatrice Dewes Moura
Ângela Beatrice Dewes Moura
CCCarlos Leonardo Pandolfo Carone
Carlos Leonardo Pandolfo Carone
FMFernando Dal Pont Morisso
Fernando Dal Pont Morisso
LSLeonardo Felix Scheffel
Leonardo Felix Scheffel
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
In many places, charcoal production, using Australian Blackwood, is still a rudimentary process, generating huge environmental impact, due to the release of pyrolysis smoke into the atmosphere. Both the society and governmental agencies is pushing the factories to condense the smoke, generating byproduct known as pyroligneous liquor. Although it's largely used for agricultural purpose, as a fertilizer and phytosanitizer, its chemical composition presents hydrogen and oxygen rich compounds, making it a potential electrolyte in the surface treatment industry, especially for anodization. Organic alternatives are being used to replace these electrolytes to make the anodizing process cleaner. Then, for the first time, Australian Blackwood pyroligneous liquor was used as an anodizing electrolyte for titanium TICP-G2, to obtain oxides for protection and coloring of the metal. For such, suitable parameters to execute the process were determined (dilution, current density, temperature, agitation, pH, conductivity) and an analysis of the transient potential over time was made. The anodized surfaces were characterized using top view Scan Electronic Microscopy (SEM) and Grazing Incidence X-ray Diffraction (GIXRD). Based on the results presented, it can be concluded that the best parameters to anodize the titanium were obtained with 50% pyroligneous liquor diluted in water, obtaining colored surfaces and promoting the formation of oxide crystallites clusters mainly in longer process times (3600s).

3 August 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
SKSandra Raquel Kunst
Sandra Raquel Kunst
DCDavid de Oliveira Cerveira
David de Oliveira Cerveira
JFJane Zoppas Ferreira
Jane Zoppas Ferreira
TGThaís Francine Graef
Thaís Francine Graef
JSJoseane de Andrade Santana
Joseane de Andrade Santana
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
Titanium has been widely used as biomaterial, especially in implantables, in which osseointegration and corrosion resistance are needed. Studies have shown that the thickness and roughness of porous titanium oxides are related to the osseointegration. According to the literature, the best anodizing conditions for obtaining nanotubes in titanium oxide are the use of a voltage of 10V in an electrolyte containing 0.15% HF in H3PO4 (w/v). In this study, was to evaluate the corrosion capacity of simulated body fluid (SBF) over titanium samples anodized on 1 mol. L-1 H3PO4 and 0.15% HF (w/v) in 1 mol.L-1 H3PO4. To perform these evaluations samples of commercially pure titanium grade 2 were used. Samples were analyzed by scanning electron microscopy, atomic force microscopy and by electrochemical corrosion tests in healthy and simulating inflammatory conditions. The hydrophobicity of oxides was tested by sessile drop essay, also using SBF. Results show that oxides obtained in H3PO4 electrolyte, barrier type oxides, work better than the porous oxides obtained in H3PO4/HF electrolyte, suggesting that barrier oxide exhibit more biomaterial characteristics than the porous oxide. These results agree with previous studies, and stand out mainly in relation to the tests performed under inflammatory conditions, more aggressive to the biomaterial.

3 February 2024 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
LFLuciane Taís Fuhr
Luciane Taís Fuhr
SKSandra Raquel Kunst
Sandra Raquel Kunst
LSLuana Góes Soares
Luana Góes Soares
ÂDÂngela Dewes
Ângela Dewes
FMFernando Dal Pont Morisso
Fernando Dal Pont Morisso
COCláudia Oliveira
Cláudia Oliveira

5 September 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
DCDavid de Oliveira Cerveira
David de Oliveira Cerveira
SKSandra Raquel Kunst
Sandra Raquel Kunst
LMLuã Tainachi Mueller
Luã Tainachi Mueller
FMFernando Dal Pont Morisso
Fernando Dal Pont Morisso
AZAna Luiza Ziulkoski
Ana Luiza Ziulkoski
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
Psidium guajava, commonly known as 'guava', belongs to the Myrtaceae family and is an alternative to the use of traditional methods of corrosion inhibition. The aim of this study is to anodize titanium in an environmentally friendly Psidium guajava electrolyte in order to improve its anti-corrosion performance. For this purpose, samples of CP (commercially pure) titanium grade 2 were anodized in plant extract based on Psidium guajava, with transient variations of current density (1 and 0.1 mA/cm²) and time (5, 30 and 60 min). Samples were characterized in terms of morphology by SEM (Scanning Electron Microscopy) analysis. The hydrophobicity of oxides was evaluated by the sessile drop method. Anodized samples were analyzed for colorimetry by the CIE L*a*b* method and the electrolyte based on Psidium guajava was analyzed by UV-Vis and cyclic voltammetry, in order to understand the compounds and their behavior in the anodizing process. From the obtained results, the oxides generated through anodization at current density of 0.1 mA/cm² were the ones that presented the best performance. The results obtained at 5 and 30 minutes of anodizing showed very similar results and greater reproducibility compared to the others analyzed, which showed the formation of a barrier-type oxide layer in the samples. In the Psidium guajava electrolyte, it was evidenced the presence of phenolic groups in its composition, which is believed to influence the process of formation of the oxide layer in the anodization process.

1 January 2020 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
SKSandra Raquel Kunst
Sandra Raquel Kunst
TGThaís Francine Graef
Thaís Francine Graef
LMLuã Tainachi Mueller
Luã Tainachi Mueller
FMFernando Dal Pont Morisso
Fernando Dal Pont Morisso
CCCarlos Leonardo Pandolfo Carone
Carlos Leonardo Pandolfo Carone
JFJane Zoppas Ferreira
Jane Zoppas Ferreira
Titanium and its alloys are the most popular metals applied on end osseous implants manufacturing. Commercially pure titanium (Ti c.p.) has been successfully used as a biomaterial because of its mechanical and chemical properties, excellent corrosion resistance and biocompatibility. In order to improve and accelerate the osseointegration process after implantation, superficial treatments are performed aiming properties that stimulate the growth of the newly-formed bone. In this work, self organized titanium dioxide (TiO2) nanotubes were obtained by anodic oxidation on Ti c.p. (grade 2). Also, it has been shown that the process is industrially reproducible for this purpose. As parameters for the anodizing process, it was concluded that the optimal electrolyte was H3PO4 solution + 0.15% HF under potentiostatic mode for 30 minutes. Potentials of 1, 5, 10, 15 and 20 V were tested in order to verify the best conditions to obtain nanotubes. In this case, potential was set at 10V. The morphology of the samples was characterized by Scanning Electron Microscopy (SEM), Scanning Electron Microscopy with Field Emission (SEM-FEG) and Atomic Force Microscopy (AFM). The results showed the nanotubes formation throughout the titanium samples surface. In accordance to the obtained roughness, it was observed that the formed nanotubes film is thin, however, the literature indicates that the film thickness is not relevant on the performance of nanostructures as optimizers of the osseointegration process, unlike the nanotubes morphology and diameter. In the wettability analysis, the nanotubes behaved as hydrophilic. Therefore, it is possible to obtain TiO2 nanotubes for using in implants by a superficial treatment, allowing a better osseointegration quality.

27 November 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
BSBruna Caroline Schmidt
Bruna Caroline Schmidt
LDLetícia Andreolli Dias
Letícia Andreolli Dias
AMAlice Helena Meinhart
Alice Helena Meinhart
SKSandra Raquel Kunst
Sandra Raquel Kunst
COCláudia Trindade Oliveira
Cláudia Trindade Oliveira
DADaiana Cristina Metz Arnold
Daiana Cristina Metz Arnold
O concreto é um material poroso que possui baixa resistência à tração, o que o torna suscetível a fissuração, possibilitando infiltração de água e agentes agressivos, tornando a armadura, se existente, vulnerável ao processo corrosivo. Assim, torna-se necessária a busca por soluções que reduzam a permeabilidade do material, e a utilização de concreto com propriedades autocicatrizantes apresenta-se como alternativa para atenuar os efeitos da fissuração. Neste sentido, o objetivo do presente trabalho é avaliar a influência da corrosão das armaduras com a utilização de concreto autocicatrizante. Para tanto, analisou-se a eficiência de um concreto com aditivo impermeabilizante por cristalização integral, com capacidade de autocicatrização de microfissuras de até 0,4 mm, comparando corpos de prova cilíndricos e prismáticos, com e sem aditivo, em ensaios de resistência à compressão, para avaliar possíveis alterações nas propriedades mecânicas do concreto, além do ensaio de corrosão acelerada para avaliar a influência do aditivo na mistura frente ao fator corrosão. Aplicou-se ciclos de imersão parcial, em solução de NaCl (3,5%), e secagem, em todos os corpos de prova e, após finalizados os ciclos, realizou-se ensaios para avaliação de corrosão. Por fim, constatou-se que a incorporação de aditivo não influenciou significativamente a resistência à compressão do concreto, além de não influenciar, de forma considerável, a prevenção de corrosão das armaduras durante o período analisado. Desta forma, não pode-se concluir que a utilização do concreto autocicatrizante analisado possa ser uma alternativa para problemas de durabilidade.