Nils Arbeiter

Nils Arbeiter

Auto-generated profile, based on publicly available information

Nils Arbeiter

Institute of General Electrical Engineering, University of Rostock, Albert-Einstein-Straße 2, 18051 Rostock, Rostock, 18051, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2023 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
MBMeike Bielfeldt
Meike Bielfeldt
KBKai Budde-Sagert
Kai Budde-Sagert
NWNikolai Weis
Nikolai Weis
MBMaren Buenning
Maren Buenning
Susanne StählkeSusanne Stählke
Susanne Stählke
J. Barbara NebeJ. Barbara Nebe
J. Barbara Nebe
Background: Electrical stimulation is used for enhanced bone fracture healing. Electrochemical processes occur during the electrical stimulation at the electrodes and influence cellular reactions. Our approach aimed to distinguish between electrochemical and electric field effects on osteoblast-like MG-63 cells. We applied 20 Hz biphasic pulses via platinum electrodes for 2 h. The electrical stimulation of the cell culture medium and subsequent application to cells was compared to directly stimulated cells. The electric field distribution was predicted using a digital twin. Results: Cyclic voltammetry and electrochemical impedance spectroscopy revealed partial electrolysis at the electrodes, which was confirmed by increased concentrations of hydrogen peroxide in the medium. While both direct stimulation and AC-conditioned medium decreased cell adhesion and spreading, only the direct stimulation enhanced the intracellular calcium ions and reactive oxygen species. Conclusion: The electrochemical by-product hydrogen peroxide is not the main contributor to the cellular effects of electrical stimulation. However, undesired effects like decreased adhesion are mediated through electrochemical products in stimulated medium. Detailed characterisation and monitoring of the stimulation set up and electrochemical reactions are necessary to find safe electrical stimulation protocols.

23 March 2026 in Journal of Tissue Engineering
Verified
Journal Article
Open access
MBMeike Bielfeldt
Meike Bielfeldt
LCLam Vien Che
Lam Vien Che
KBKai Budde-Sagert
Kai Budde-Sagert
NANils Arbeiter
Nils Arbeiter
Susanne StählkeSusanne Stählke
Susanne Stählke
JZJulius Zimmermann
Julius Zimmermann
Electrical stimulation holds promise for enhancing bone healing; however, it has not yet seen widespread clinical adoption. A significant obstacle is the limited understanding of the biological mechanisms involved and the electric field parameters required to trigger them. It has been observed that the intracellular calcium ion concentration increases upon electrical stimulation, possibly via the activation of voltage-gated calcium channels. In this work, we introduced a digital twin framework to rationally choose stimulation parameters. We aimed to induce a transmembrane potential sufficient to activate the voltage-gated calcium channels. We focused on kilohertz-frequency stimulation, which offers advantages for clinical translation, and applied electrical stimuli using a well-established direct-contact stimulation chamber. By combining this with live-cell calcium imaging, we observed the immediate stimulation effect. We found that a stimulation at 1 kHz or 100 kHz, adjusted to induce a transmembrane potential of about 10 mV, did not alter the intracellular calcium concentration. In contrast, direct current stimulation at 5 V consistently increased intracellular calcium concentrations. However, our results indicate that this effect is not caused by the electric field itself but by electrochemical by-products leading to local changes in the pH value. We further confirmed that chemical stimulation could reproduce the effect. The presented workflow enables researchers to distinguish between purely electrical and mixed electrochemical stimulation. It is easily transferable and contributes to a more precise understanding of the effects of electrical stimulation.

15 February 2023 in Brain Stimulation
Verified
Journal Article
Open access
MKMaria Kober
Maria Kober
FBFelix Bernsdorff
Felix Bernsdorff
JZJulius Zimmermann
Julius Zimmermann
MSMeike Statz
Meike Statz
JLJennifer Lanto
Jennifer Lanto
ASAlexander Storch
Alexander Storch

29 April 2026 in Journal of Neural Engineering
Verified
Journal Article
Open access
JPJan Philipp Payonk
Jan Philipp Payonk
MKMaria Kober
Maria Kober
KBKai Budde-Sagert
Kai Budde-Sagert
FBFelix Bernsdorff
Felix Bernsdorff
MSMeike Statz
Meike Statz
JZJulius Zimmermann
Julius Zimmermann
Objective: Deep brain stimulation is an established therapy for neurological disorders such as Parkinson's disease, but its underlying mechanisms and tissue effects remain incompletely understood. A particular challenge arises from the foreign body response to implanted electrodes, which leads to scar formation and encapsulation, altering the electrical properties of the surrounding tissue. This study aims to characterize the electrode-tissue interface during long-term stimulation and to improve model-based estimation of the stimulation volume using subject-specific dielectric properties. Approach: Continuous deep brain stimulation was delivered for six weeks using a fully implantable stimulator in a unilateral 6-hydroxydopamine Parkinson rat model. In vivo impedance spectroscopy and post mortem histology were performed to assess encapsulation tissue properties. Principal component analysis was applied to identify group differences in the impedance spectra. Encapsulation layer thickness was quantified histologically and incorporated into subject-specific numerical models to resolve the non-identifiability between layer thickness and dielectric parameters. Dielectric properties were estimated by fitting simulated spectra to experimental measurements. Main results: Impedance spectra differed significantly between stimulated and non-stimulated animals, indicating that impedance spectroscopy can distinguish tissue responses to chronic stimulation. Incorporating subject-specific encapsulation parameters substantially altered estimates of the stimulation volume compared to conventional assumptions. Significance: By integrating in vivo measurements, histology, and computational modeling, this study replaces generic interface assumptions with subject-specific electrode-tissue properties. The results identify measurable markers of encapsulation tissue and demonstrate that conventional modeling approaches overestimate the stimulation volume when generic interface assumptions are used. Incorporating subject-specific electrode–tissue properties improves the reliability of deep brain stimulation simulations and supports individualized stimulation strategies.