Meike Bielfeldt

Meike Bielfeldt

Auto-generated profile, based on publicly available information

Meike Bielfeldt

Institute of Cell Biology, Rostock University Medical Centre, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Cells
Verified
Journal Article
Open access
PDF file
Susanne StählkeSusanne Stählke
Susanne Stählke
MBMeike Bielfeldt
Meike Bielfeldt
JZJulius Zimmermann
Julius Zimmermann
MGMartina Gruening
Martina Gruening
IBIngo Barke
Ingo Barke
J. Barbara NebeJ. Barbara Nebe
J. Barbara Nebe
An extensive research field in regenerative medicine is electrical stimulation (ES) and its impact on tissue and cells. The mechanism of action of ES, particularly the role of electrical parameters like intensity, frequency, and duration of the electric field, is not yet fully understood. Human MG-63 osteoblasts were electrically stimulated for 10 min with a commercially available multi-channel system (IonOptix). We generated alternating current (AC) electrical fields with a voltage of 1 or 5 V and frequencies of 7.9 or 20 Hz, respectively. To exclude liquid-mediated effects, we characterized the AC-stimulated culture medium. AC stimulation did not change the medium’s pH, temperature, and oxygen content. The H2O2 level was comparable with the unstimulated samples except at 5 V_7.9 Hz, where a significant increase in H2O2 was found within the first 30 min. Pulsed electrical stimulation was beneficial for the process of attachment and initial adhesion of suspended osteoblasts. At the same time, the intracellular Ca2+ level was enhanced and highest for 20 Hz stimulated cells with 1 and 5 V, respectively. In addition, increased Ca2+ mobilization after an additional trigger (ATP) was detected at these parameters. New knowledge was provided on why electrical stimulation contributes to cell activation in bone tissue regeneration.

9 September 2022 in Biomedical Materials & Devices
Verified
Journal Article
Open access
PDF file
MBMeike Bielfeldt
Meike Bielfeldt
HRHenrike Rebl
Henrike Rebl
KPKirsten Peters
Kirsten Peters
KSKaarthik Sridharan
Kaarthik Sridharan
Susanne StählkeSusanne Stählke
Susanne Stählke
J. Barbara NebeJ. Barbara Nebe
J. Barbara Nebe
The development of new biomaterials and medical devices has become a growing field of interdisciplinary research. The medical devices for tissue and cell treatments are being constructed for the application in regenerative medicine. There are many different approaches to improve cellular functions and it is known that physical stimuli affect cell physiology such as proliferation and differentiation. In this review we focus on electrical and mechanical stimulation as well as cold atmospheric pressure plasma treatment and photobiomodulation. Bone forming cells show improved proliferation and migration after electrical stimulation, which is used as treatment in bone fracture healing and to enhance osseointegration. Especially mechanical forces have direct effects on central cell signalling pathways and cell adhesion to biomaterial surfaces. Physical plasma promotes tissue regeneration and exhibits anti-carcinogenic effects, while light of different wavelengths also improves wound healing and tissue repair by influencing stem cell fate. Although the treatment approaches are different, all these physical factors lead to the activation of cell signalling via calcium and reactive oxygen species. A better understanding of the cellular response to the applied stimuli will help develop efficient treatment strategies and optimised device settings.

23 November 2023 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
MBMeike Bielfeldt
Meike Bielfeldt
KBKai Budde-Sagert
Kai Budde-Sagert
NWNikolai Weis
Nikolai Weis
MBMaren Buenning
Maren Buenning
Susanne StählkeSusanne Stählke
Susanne Stählke
J. Barbara NebeJ. Barbara Nebe
J. Barbara Nebe
Background: Electrical stimulation is used for enhanced bone fracture healing. Electrochemical processes occur during the electrical stimulation at the electrodes and influence cellular reactions. Our approach aimed to distinguish between electrochemical and electric field effects on osteoblast-like MG-63 cells. We applied 20 Hz biphasic pulses via platinum electrodes for 2 h. The electrical stimulation of the cell culture medium and subsequent application to cells was compared to directly stimulated cells. The electric field distribution was predicted using a digital twin. Results: Cyclic voltammetry and electrochemical impedance spectroscopy revealed partial electrolysis at the electrodes, which was confirmed by increased concentrations of hydrogen peroxide in the medium. While both direct stimulation and AC-conditioned medium decreased cell adhesion and spreading, only the direct stimulation enhanced the intracellular calcium ions and reactive oxygen species. Conclusion: The electrochemical by-product hydrogen peroxide is not the main contributor to the cellular effects of electrical stimulation. However, undesired effects like decreased adhesion are mediated through electrochemical products in stimulated medium. Detailed characterisation and monitoring of the stimulation set up and electrochemical reactions are necessary to find safe electrical stimulation protocols.

17 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMaren E. Buenning
Maren E. Buenning
MBMeike Bielfeldt
Meike Bielfeldt
J. Barbara NebeJ. Barbara Nebe
J. Barbara Nebe
Susanne StählkeSusanne Stählke
Susanne Stählke
Electrical stimulation (ES) and its effects on biological systems is an area of research in regenerative medicine. The focus here is on the mechanism of action of ES on cell membrane-related components. A short alternating current (AC) stimulation (10 min) was applied on suspended human MG-63 osteoblasts via a commercially available multi-channel system (IonOptix). The pulsed ES with 1 V or 5 V and frequencies of 20 Hz on cells was performed immediately after cell seeding. The in vitro investigations were conducted by microscopy, flow cytometry, and particle analysis via a Litesizer within 24 h. The short-time ES with the parameter 1 V and 20 Hz was beneficial for the process of cell attachment, which could be related to an enhanced deposition of fibronectin on the glass bottom from the protein-containing medium (10% FBS). The MG-63 cells’ spherical coat hyaluronan remained constant and did not contribute to this AC-triggered adhesion. In this context, the cells’ zeta potential also did not play a role. The membrane potential analyzed via DiBAC4(3) was unchanged. Only the aquaporin channel AQP 8 in the cell membrane was significantly enhanced. Suspended cells in an AC electric field were activated during their settlement, and the fibronectin adsorption on the bottom contributed to this effect but not the membrane-related components.

23 March 2026 in Journal of Tissue Engineering
Verified
Journal Article
Open access
MBMeike Bielfeldt
Meike Bielfeldt
LCLam Vien Che
Lam Vien Che
KBKai Budde-Sagert
Kai Budde-Sagert
NANils Arbeiter
Nils Arbeiter
Susanne StählkeSusanne Stählke
Susanne Stählke
JZJulius Zimmermann
Julius Zimmermann
Electrical stimulation holds promise for enhancing bone healing; however, it has not yet seen widespread clinical adoption. A significant obstacle is the limited understanding of the biological mechanisms involved and the electric field parameters required to trigger them. It has been observed that the intracellular calcium ion concentration increases upon electrical stimulation, possibly via the activation of voltage-gated calcium channels. In this work, we introduced a digital twin framework to rationally choose stimulation parameters. We aimed to induce a transmembrane potential sufficient to activate the voltage-gated calcium channels. We focused on kilohertz-frequency stimulation, which offers advantages for clinical translation, and applied electrical stimuli using a well-established direct-contact stimulation chamber. By combining this with live-cell calcium imaging, we observed the immediate stimulation effect. We found that a stimulation at 1 kHz or 100 kHz, adjusted to induce a transmembrane potential of about 10 mV, did not alter the intracellular calcium concentration. In contrast, direct current stimulation at 5 V consistently increased intracellular calcium concentrations. However, our results indicate that this effect is not caused by the electric field itself but by electrochemical by-products leading to local changes in the pH value. We further confirmed that chemical stimulation could reproduce the effect. The presented workflow enables researchers to distinguish between purely electrical and mixed electrochemical stimulation. It is easily transferable and contributes to a more precise understanding of the effects of electrical stimulation.