Hongfeng Ma

Hongfeng Ma

Auto-generated profile, based on publicly available information

Hongfeng Ma

Laboratoire Hubert Curien, CNRS UMR 5516, Institut d’Optique Graduate School, Université Lyon, 42000 St-Etienne, France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2022 in ACS Nano
Verified
Journal Article
Closed access
HMHongfeng Ma
Hongfeng Ma
NDNicolas Dalloz
Nicolas Dalloz
AHAmaury Habrard
Amaury Habrard
MSMarc Sebban
Marc Sebban
FSFlorian Sterl
Florian Sterl
Nathalie DestouchesNathalie Destouches
Nathalie Destouches

29 December 2015 in Medical Physics
Verified
Journal Article
Open access
DSD. Stassi
D. Stassi
SDSheetij Dutta
Sheetij Dutta
HMH. Ma
H. Ma
ASA. Soderman
A. Soderman
DPD. Pazzani
D. Pazzani
TST. G. Schmidt
T. G. Schmidt
Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, making it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiacCT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three readers using a five point Likert scale. Results: There was no statistically significant difference between inter-reader and reader-algorithm agreement for either MAD or CCC metrics (p > 0.1). The algorithm phase was within 2% of the consensus phase in 15/21 of cases. The average absolute difference between consensus and algorithm best phases was 2.29% ± 2.47%, with a maximum difference of 8%. Average image quality scores for the algorithm chosen best phase were 4.01 ± 0.65 overall, 3.33 ± 1.27 for right coronary artery (RCA), 4.50 ± 0.35 for left anterior descending (LAD) artery, and 4.50 ± 0.35 for left circumflex artery (LCX). Average image quality scores for the consensus best phase were 4.11 ± 0.54 overall, 3.44 ± 1.03 for RCA, 4.39 ± 0.39 for LAD, and 4.50 ± 0.18 for LCX. There was no statistically significant difference (p > 0.1) between the image quality scores of the algorithm phase and the consensus phase. Conclusions: The proposed algorithm was statistically equivalent to a reader in selecting an optimal cardiac phase for CCTA exams. When reader and algorithm phases differed by >2%, image quality as rated by blinded readers was statistically equivalent. By detecting the optimal phase for CCTA reconstruction, the proposed algorithm is expected to improve coronary artery visualization in CCTA exams.

23 December 2017 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
ARAnton Rudenko
Anton Rudenko
HMHongfeng Ma
Hongfeng Ma
VVVadim P. Veiko
Vadim P. Veiko
JCJean-Philippe Colombier
Jean-Philippe Colombier
Tatiana E. ItinaTatiana E. Itina
Tatiana E. Itina

1 January 2017 in Optics Communications
Verified
Journal Article
Closed access
BYBo Yan
Bo Yan
KZKesong Zhong
Kesong Zhong
HMHongfeng Ma
Hongfeng Ma
YLYun Li
Yun Li
CSChenghua Sui
Chenghua Sui
YSYi Shi
Yi Shi

1 April 2020 in Materials Research Express
Verified
Journal Article
Open access
FGFan Gao
Fan Gao
JZJunwen Zhu
Junwen Zhu
HMHongfeng Ma
Hongfeng Ma
KLKexue Li
Kexue Li
PYPeicheng Yuan
Peicheng Yuan
BYBo Yan
Bo Yan
The circular dichroism effect characterized by different optical responses between left-handed and right-handed circularly polarized lights is widely applied for biological monitoring, analytical chemistry, and plasmonic sensing. Despite the fact that circular dichroisms are achieved by many conventional chiral and anisotropic metamaterials, dynamic and efficient modulation of circular dichroisms is still challenging. In this paper, we demonstrate a VO2 embedded metamaterial enabling tunable chirality by taking advantages of the VO2 phase transitions between insulators and metals. Specifically, by changing the laser power and the irradiated position on the metamaterial, the VO2 phase transition takes place at the irradiated region and induces a tunable circular dichroism effect. This work provides a strategy for the active control and modulation of circular polarizations, which pays the way for applications in terahertz and microwave regions.

21 December 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
HMHongfeng Ma
Hongfeng Ma
RZRoman A. Zakoldaev
Roman A. Zakoldaev
ARAnton Rudenko
Anton Rudenko
MSMaksim M. Sergeev
Maksim M. Sergeev
VVVadim P. Veiko
Vadim P. Veiko
Tatiana E. ItinaTatiana E. Itina
Tatiana E. Itina
We report control possibilities over ultrafast laser-induced periodic void lines in porous glass. Instead of high intensity regime leading to filaments, multi-pulse irradiation with high repetition rate (500 kHz) and various writing speed is used here in a transverse geometry. The formation of a perfectly controlled periodic void structure is shown to rely on such parameters as laser energy per pulse and scanning speed. In particular, both the threshold energy required for this effect and the period of the fabricated void arrays are shown to rise linearly with the number of the applied laser pulses per spot, or with a decreasing writing speed. To explain these results, a thermodynamic analysis is performed. The obtained dependencies are correlated with linear energy losses, whereas the periodicity of the observed structures is attributed to a static energy source formation at the void location affecting both material density and laser energy absorption.