Opportunistic premise plumbing pathogens such as Pseudomonas aeruginosa and Naegleria fowleri are a growing concern in building water systems because of their potential risks to human health. The aim of this study was to determine the critical concentrations of P. aeruginosa and N. fowleri in water that are associated with meaningful public health risks. To determine these concentrations, a reverse quantitative microbial risk assessment (QMRA) was conducted. Environmental concentrations of P. aeruginosa and N. fowleri corresponding to the risk target of one micro-disability-adjusted life year (DALY) per person per year and 10−4 annual risks of illness were calculated for several applicable exposure scenarios. To calculate the concentration of P. aeruginosa, cleaning contact lenses with potentially contaminated tap water in the absence of an appropriate cleaning solution was considered. For N. fowleri, two exposure scenarios, recreational exposure (swimming) and nasal cleansing (via the use of a neti pot™ or similar device) were considered. The highest critical concentration for P. aeruginosa was found to be 33 CFU/L with a 95% confidence interval of (2.0, 118) for the drop exposure scenario using the 10−4 annual risk target. For N. fowleri, based on the DALY approach, critical concentrations were 0.000030 N. fowleri/L for swimming and 0.00000060 N. fowleri/L for neti pot™ use scenario. Considering heat inactivation, the critical concentration limits for P. aeruginosa using the DALY approach and the 10−4 annual risk target approach were found to be 0.55 CFU/L and 55 CFU/L, respectively. For N. fowleri, the 10−4 annual risk target approach resulted in 0.022 N. fowleri/L and the DALY approach resulted in 0.00000064 N. fowleri/L for the neti pot™ scenario. For P. aeruginosa, N50 (the median infective dose) and alpha (α) contributed the most and contact rates the least to the variability and uncertainty of the estimates for all the scenarios. For N. fowleri, N50 and contact rates contributed the most and α the least to the variability and uncertainty to calculate the concentrations for all the scenarios. The QMRA framework implemented in this research can be used to incorporate more information regarding opportunistic pathogens to inform management decisions, and to prioritize the best interventions regarding estimated reduction in infections caused by opportunistic pathogens.
This study examines the influence of chlorine disinfectant type, water use frequency (stagnation time), and water heater temperature on the growth and persistence of microbes, including nontuberculous mycobacteria (NTM), in water heater storage tanks and downstream plumbing. The experimental setup consists of four 50-gallon electric water heater tanks at two different locations that provide different types of secondary disinfectant (chloramine and free chlorine). The water heaters were operated at two different temperature settings (45°C ± 3°C and 60°C ± 3°C), and with two different use patterns (once per 24 h and three times per 24 h), which allowed for sampling at three different stagnation times: overnight, 16-h stagnation, and 3-h stagnation. Microbial analyses were conducted on water samples collected at the tank effluent and the shower head to compare the water quality in the tank before the stagnation period and in the piping downstream of the tank after the stagnation period. The results indicated that culturable NTM was not detected under any of the conditions studied in the free chlorine disinfectant system. In the chloramine system, higher water use frequency (equivalent to 180 gallons/day) and higher water heater temperature (60°C ± 3°C) decreased the number of heterotrophic bacteria in the tank and the piping downstream to the tank but failed to control NTM. For both heterotrophic plate count and NTM, the piping downstream was not more microbially active than the tank.
Real-time monitoring of phytoplankton in freshwater systems is critical for early detection of harmful algal blooms so as to enable efficient response by water management agencies. This paper presents an image processing pipeline developed to adapt ARTiMiS, a low-cost automated flow-imaging device, for real-time algal monitoring specifically in freshwater and environmental systems. This pipeline addresses several challenges associated with autonomous imaging of aquatic samples such as flow-imaging artifacts (i.e., out-of-focus and background objects), as well as specific challenges associated with monitoring of open environmental systems (i.e., identification of novel objects). The pipeline leverages a Random Forest model to identify out- of-focus particles with an accuracy of 89% and a custom background particle detection algorithm to identify and remove particles that erroneously appear in consecutive images with >97±2.8% accuracy. Furthermore, a convolutional neural network (CNN), trained to classify distinct classes comprising both taxonomical and morphological categories, achieved 94% accuracy in a closed dataset. Nonetheless, the supervised closed-set classifiers struggled with the accurate classification of objects when challenged with debris and novel particles which are common in complex open environments; this limits real-time monitoring applications by requiring extensive manual oversight. To mitigate this, three methods incorporating classification with rejection were tested to improve model precision by excluding irrelevant or unknown classes. Combined, these advances present a fully integrated, end-to-end solution for real-time HAB monitoring in open environmental systems thus enhancing the scalability of automated detection in dynamic aquatic environments. Highlights: Random Forest model is more generalizable than Convolutional Neural Networks to remove out-of-focus particles. A two-stage clustering algorithm is effective at removing background particles in flow imaging microscopy. Closed-set CNN classifier performance deteriorates when challenged with unknown particles. Classification with rejection improves both precision and accuracy for environmental samples.
The authors regret to report that the paper “Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri” contains some erroneous computations