6 June 2023 in IEEE Transactions on Energy Conversion
Previous studies regards that the grid-forming (GFM) converter switches from the constant voltage control (CVC) to the current limiting control (CLC) at the point of intersection of the unsaturated and saturated power-angle curves, which might not be held in most situations. This paper firstly derives the switching rule of GFM converter between two controls from the current limiting inequality. Accordingly, the conventional algebraic-variable switched model is transferred to the proposed state-variable switched model. Based on Lyapunov Theory, the stability of equilibrium points (EPs) is studied and the stable regions under two controls are further derived. In addition, one necessary stabilizing condition for the power synchronization loop based GFM (PSL-GFM) converter being locked in CLC is derived. As a result, one global stabilization on CVC is proposed by regulating the angle between the saturated current vector and d-axis . Finally, the maximum system boundary of the first swing can be obtained by placing stable equilibrium points (SEPs) under CLC on the right switching line.
9 May 2024 in IEEE Transactions on Power Systems
This paper investigates the synchronization stability of one multiple virtual synchronous generators (VSGs) embedded power system with the current saturation and limits of frequency. The dynamic model of the multiple VSGs integrated system with controller limits is built. Accordingly, the transient energy function (TEF) for the autonomous system without touching controller limits is established, and the stability region is determined via the method of the closet unstable equilibrium point (UEP). Further, it is found that the system leaves away from the bounds of frequency at several leaving bound points . Among these, there exists two special ones with the minimal transient energy, and they are fixed irrespective of the switching times. Finally, one stabilizing condition is proposed that only if the energy of two special leaving bound points is less than the system critical energy, the global stability is ensured. The system critical energy is determined by the minimum of two values, namely, the method by closet UEP, and the maximum potential energy to ensure the system does not enter the mode of current limiting control (CLC). The numerical simulations of 9-buses and 39-buses power systems have verified the correctness of the proposed analysis.
19 January 2023 in IEEE Transactions on Power Systems
This paper investigates the large disturbance stability of single voltage source converter (VSC) connected to the infinite bus system through the transmission line. One conservative stable region is obtained via the direct method of Lyapunov. Based on the Poincaré Theorem, it is interesting to find there might exist limit cycle between the obtained stable boundary and the angle of unstable equilibrium point (UEP). Accordingly, the nonlinear damping effect on the system stability is defined, and one limit cycle exists when the positive and negative damping effect over one period is mutually balanced. A conservative existence condition of limit cycle is further derived by constructing a proper piece-wise curve to approximate one specified unstable system trajectory. The derived analytical existence condition can directly predict the limit cycle without numerical simulations. Finally, the paper also proves that the studied dynamic system has at most one limit cycle, and if it exists, it is unstable.
8 May 2024 in International Journal of Electrical Power & Energy Systems
30 March 2023 in Electric Power Systems Research
5 May 2023 in IEEE Transactions on Power Systems
The robust stability of one single voltage source converter (VSC) connected to a bus via the line is studied in this letter. Considering arbitrary bounded perturbations from uncertainties, the perturbed system model is firstly proposed. Then, one switched system is constructed to investigate the stability of the perturbed system, and it is proved that the stability region of the switched system is the subset of that of the perturbed system. Finally, the stability region of the switched system is obtained by the inverse-time (backwards) integration starting from the unstable equilibrium point, which is also the conservative stability region of the perturbed system.