6 June 2023 in IEEE Transactions on Energy Conversion
Previous studies regards that the grid-forming (GFM) converter switches from the constant voltage control (CVC) to the current limiting control (CLC) at the point of intersection of the unsaturated and saturated power-angle curves, which might not be held in most situations. This paper firstly derives the switching rule of GFM converter between two controls from the current limiting inequality. Accordingly, the conventional algebraic-variable switched model is transferred to the proposed state-variable switched model. Based on Lyapunov Theory, the stability of equilibrium points (EPs) is studied and the stable regions under two controls are further derived. In addition, one necessary stabilizing condition for the power synchronization loop based GFM (PSL-GFM) converter being locked in CLC is derived. As a result, one global stabilization on CVC is proposed by regulating the angle between the saturated current vector and d-axis . Finally, the maximum system boundary of the first swing can be obtained by placing stable equilibrium points (SEPs) under CLC on the right switching line.
9 May 2024 in IEEE Transactions on Power Systems
This paper investigates the synchronization stability of one multiple virtual synchronous generators (VSGs) embedded power system with the current saturation and limits of frequency. The dynamic model of the multiple VSGs integrated system with controller limits is built. Accordingly, the transient energy function (TEF) for the autonomous system without touching controller limits is established, and the stability region is determined via the method of the closet unstable equilibrium point (UEP). Further, it is found that the system leaves away from the bounds of frequency at several leaving bound points . Among these, there exists two special ones with the minimal transient energy, and they are fixed irrespective of the switching times. Finally, one stabilizing condition is proposed that only if the energy of two special leaving bound points is less than the system critical energy, the global stability is ensured. The system critical energy is determined by the minimum of two values, namely, the method by closet UEP, and the maximum potential energy to ensure the system does not enter the mode of current limiting control (CLC). The numerical simulations of 9-buses and 39-buses power systems have verified the correctness of the proposed analysis.
18 December 2024 in IEEE Transactions on Power Systems
The existing priority-based current limiting control (CLC) for grid-forming (GFM) inverters may lead to failures in fault recovery, including being locked in CLC and mode oscillation between CLC and constant voltage control (CVC). To resolve these problems, this letter first reveals the fault recovery mechanism of droop controlled GFM inverters by illustrating the conditions of three fault recovery states in the phasor diagram. Then, two methods including determination of the optimal range of current angle and upper limit of saturation block are presented to guarantee successful fault recovery of GFM inverters. The correctness of theoretical analyses is verified and validated by multiple experimental tests.
18 September 2025 in International Journal of Electrical Power & Energy Systems
1 January 2026 in IEEE Transactions on Power Electronics
1 July 2026 in IEEE Transactions on Power Systems