Jong Sung Park

Jong Sung Park

Auto-generated profile, based on publicly available information

Jong Sung Park

DEMO Technology Division, National Fusion Research Institute, Daejeon, South Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2016 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
KIKihak Im
Kihak Im
SKSungjin Kwon
Sungjin Kwon
JPJong Sung Park
Jong Sung Park
A preconceptual design study for the Korean fusion demonstration tokamak reactor (K-DEMO) has been started in 2012. The results of the preliminary concept study on the K-DEMO divertor are summarized in this paper. An up-down symmetric double-null configuration is selected as a primary choice for study with high elongation of 2 and the triangularity of 0.625. For the vertical maintenance of the K-DEMO in-vessel components, upper and lower divertors are subdivided into 32 toroidal modules, respectively. With maintaining its functionality, the poloidal coverage of divertor is restricted to maximize the breeding area of blanket. The plasma radiation from the core and the edge plasma and the fusion neutron wall loading onto the first walls of the in-vessel components were calculated as heat sources to the structures of the in-vessel components. The divertor targets are tilted at ~10° against separatrix field line to handle the conceived engineering limit of steady 10 MW/m 2 of peak heat flux with ~50% of core plasma radiation and ~85% of divertor plasma radiation. Divertor adopts tungsten monoblock targets, reduced activation steel-based structures carrying the pressurized water coolant. Also, the preliminary electromagnetic force extrapolated from the ITER disruption events was considered as a mechanical load to the structures in addition to the coolant pressure. The developed concept on the target and structure is supported by preliminary thermohydraulic and structural analyses using ANSYS, which show that the temperature and the stresses are within their allowables.

24 August 2016 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
JPJ. S. Park
J. S. Park
KIK. Im
K. Im
SKS. Kwon
S. Kwon
Neutronic assessment is the important foundation of Korean fusion demonstration reactor (K-DEMO) study. Previously, preliminary neutronic calculations using a simplified model have been performed [1], and optimized structure of blanket module and shield material has been derived. Based on the previous calculation results, the advanced K-DEMO neutronic analysis model has been developed to perform more accurate and reliable neutronic assessments with the detailed configuration of vacuum vessel (VV), toroidal field (TF) coil, blanket, and shield. The advanced K-DEMO neutronic analysis model was imported into the integrated interface program by the help of Monte Carlo automatic modeling system to produce input files for the Monte Carlo neutron photon transport code analyses. The neutronic calculation on neutron wall loading (NWL) distribution, tritium breeding ratio (TBR), and nuclear heating in tokamak components was conducted for the newly developed advanced K-DEMO neutronic analysis model. In the NWL calculation, the peak was indicated at the inboard (IB) and the outboard (OB) blanket first wall with the value of 3.81 and 3.93 MW/m2. The different types of models by changing gaps between the blanket modules and the thickness of separated borated steel shield blocks are calculated to check global TBR and the shield performance. The global TBR of 1.017 was achieved with the 49.7and 76.2-cm-thick IB and OB blanket modules. The model with 1-cm-thick assembly gap between blanket modules, 22-cm-thick IB shield, 50-cm-thick OB shield, and 34-cm-thick divertor shield are considered as a reasonable shield model with the total nuclear heating in 16 TF coils and VV of 9 and 32 kW.

19 April 2018 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
JPJongsung Park
Jongsung Park
SKSungjin Kwon
Sungjin Kwon
KIKihak Im
Kihak Im
BKByungchul Kim
Byungchul Kim
SHSuk-Ho Hong
Suk-Ho Hong
This paper presents a shutdown dose rate (SDR) calculation to estimate a newly developed preliminary concept of the equatorial port model for the Korean fusion demonstration reactor (K-DEMO). The equatorial port model was designed to provide effective radiation shielding abilities adopting the port shielding block and labyrinth structure, which was integrated into the modified K-DEMO neutronic analysis model by the Monte Carlo automatic modeling system. A rigorous two-step method was applied to couple transport (MCNP) and activation (FISPACT) codes according to three steps of calculation procedures. The results of neutron flux and decay gamma transport calculation for the equatorial port area have been indicated in this paper. The SDR calculation result near the equatorial port area reveals that a dose level in the equatorial port interspace was below 100 μSv/h after 12 days of the shutdown. Shielding blocks and two labyrinth structures prove that they effectively attenuate neutrons on the current concept of the equatorial port model.

12 October 2017 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
JPJ. Park
J. Park
KIK. Im
K. Im
SKS. Kwon
S. Kwon
JKJ. Kim
J. Kim
DKD. Kim
D. Kim
CSC. Shin
C. Shin
This paper addresses nuclear analysis on the Korean fusion demonstration reactor (K-DEMO) divertor to estimate the overall trend of nuclear heating values and displacement damages. The K-DEMO divertor model was created and converted by the CAD (Pro-Engineer™) and Monte Carlo automatic modeling programs as a 22.5° sector of the tokamak. The Monte Carlo neutron photon transport and ADVANTG codes were used in this calculation with the FENDL-2.1 nuclear data library. The calculation results indicate that the highest values appeared on the upper outboard target (OT) area, which means the OT is exposed to the highest radiation conditions among the three plasma-facing parts (inboard, central and outboard) in the divertor. Especially, much lower nuclear heating values and displacement damages are indicated on the lower part of the OT area than others. These are important results contributing to thermal-hydraulic and thermo-mechanical analyses on the divertor and also it is expected that the copper alloy materials may be partially used as a heat sink only at the lower part of the OT instead of the reduced activation ferritic-martensitic steel due to copper alloy's high thermal conductivity.