Stijn Vandenberghe

Stijn Vandenberghe

Auto-generated profile, based on publicly available information

Stijn Vandenberghe

Department of Cardiac Surgery, Cardiocentro Ticino, Lugano, Switzerland

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2012 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
AZAdrian Zurbuchen
Adrian Zurbuchen
APA. Pfenniger
A. Pfenniger
ASA. Stahel
A. Stahel
CSC. T. Stoeck
C. T. Stoeck
SVS. Vandenberghe
S. Vandenberghe
RVRolf Vogel
Rolf Vogel

27 November 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GOGregor Ochsner
Gregor Ochsner
RARaffael Amacher
Raffael Amacher
AAAlois Amstutz
Alois Amstutz
APAndre Plass
Andre Plass
MDMarianne Schmid Daners
Marianne Schmid Daners
LGLino Guzzella
Lino Guzzella
This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

26 July 2002 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
KDKris Dumont
Kris Dumont
JYJessa Yperman
Jessa Yperman
EVErik Verbeken
Erik Verbeken
PSPatrick Segers
Patrick Segers
BMBart Meuris
Bart Meuris
PVPascal R. Verdonck
Pascal R. Verdonck

1 October 2012 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
TPTohid Pirbodaghi
Tohid Pirbodaghi
SFShannon Axiak Flammer
Shannon Axiak Flammer
AWAlberto Weber
Alberto Weber
TGThomas Gempp
Thomas Gempp
SVStijn Vandenberghe
Stijn Vandenberghe

21 November 2013 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
GOGregor Ochsner
Gregor Ochsner
RARaffael Amacher
Raffael Amacher
MWMarkus J. Wilhelm
Markus J. Wilhelm
SVStijn Vandenberghe
Stijn Vandenberghe
HTHendrik Tevaearai
Hendrik Tevaearai
MDMarianne Schmid Daners
Marianne Schmid Daners

1 January 2006 in ASAIO Journal
Verified
Journal Article
Closed access
SVStijn Vandenberghe
Stijn Vandenberghe
PSPatrick Segers
Patrick Segers
PSPaul Steendijk
Paul Steendijk
BMBart Meyns
Bart Meyns
RDRobert A.E. Dion
Robert A.E. Dion
PVPascal Verdonck
Pascal Verdonck
The time-varying elastance theory of Suga et al. is widely used to simulate left ventricular function in mathematical models and in contemporary in vitro models. We investigated the validity of this theory in the presence of a left ventricular assist device. Left ventricular pressure and volume data are presented that demonstrate the heart-device interaction for a positive-displacement pump (Novacor) and a rotary blood pump (Medos). The Novacor was implanted in a calf and used in fixed-rate mode (85 BPM), whereas the Medos was used at several flow levels (0–3 l/min) in seven healthy sheep. The Novacor data display high beat-to-beat variations in the amplitude of the elastance curve, and the normalized curves deviate strongly from the typical bovine curve. The Medos data show how the maximum elastance depends on the pump flow level. We conclude that the original time-varying elastance theory insufficiently models the complex hemodynamic behavior of a left ventricle that is mechanically assisted, and that there is need for an updated ventricular model to simulate the heart–device interaction.