Xianglong Duan

Xianglong Duan

Auto-generated profile, based on publicly available information

Xianglong Duan

The College of Life Sciences and Medicine Northwest University xi'an China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
KZKang Zhao
Kang Zhao
HJHanjun Jiang
Hanjun Jiang
ZWZhihua Wang
Zhihua Wang
PCPing Chen
Ping Chen
BZBinjie Zhu
Binjie Zhu
XDXianglong Duan
Xianglong Duan
Bowel sounds (BSs), typically generated by the intestinal peristalses, are a significant physiological indicator of the digestive system's health condition. In this study, a wearable BS monitoring system is presented for long-term BS monitoring. The system features a wearable BS sensor that can record BSs for days long and transmit them wirelessly in real-time. With the system, a total of 20 subjects' BS data under the hospital environment were collected. Afterward, CNNs are introduced for BS segment recognition. Specifically, this study proposes a novel CNN design method that makes it possible to transfer the popular CNN modules in image recognition into the BS segmentation domain. Experimental results show that in holdout evaluation with corrected labels, the designed CNN model achieves a moderate accuracy of 91.8% and the highest sensitivity of 97.0% compared with the similar works. In cross validation with noisy labels, the designed CNN delivers the best generability.

6 September 2021 in Molecular Medicine Reports
Verified
Journal Article
Open access
PDF file
CXCuixiang Xu
Cuixiang Xu
XHXiaoyan Huang
Xiaoyan Huang
YHYubin Huang
Yubin Huang
XLXiao Liu
Xiao Liu
MWMin Wu
Min Wu
XDXianglong Duan
Xianglong Duan
Naringin (Nar) is one of the natural glycosides extracted from pomelo and other citrus fruits. It has various pharmacological activities, including anti‑inflammatory, antioxidant, anti‑proliferative and anti‑cancer. However, the underlying mechanisms by which Nar regulates apoptosis and autophagy in gastric cancer remain unclear. Thus, the present study aimed to assess the therapeutic effect of Nar and the underlying mechanisms. SNU‑1 cell proliferation was determined using Cell Counting Kit‑8 assay. Cell morphological changes were observed under a phase‑contrast microscope. The changes in the cell cycle were determined using flow cytometry analysis and the changes in cell apoptosis were determined using flow cytometry, Hoechst 33258 and TUNEL staining. The protein levels pertaining to the PI3K/AKT pathway and cell apoptosis and autophagy were monitored using western blot analysis. The results demonstrated that Nar significantly inhibited SNU‑1 cell growth and induced cell cycle arrest in the G0/G1 phase and cell apoptosis. Further mechanistic studies demonstrated that Nar blocked the PI3K/AKT pathway, activated cell autophagy and stimulated the expression of apoptosis‑associated protein cleaved caspase 3 and Bax, but decreased the expression of Bcl‑2. Preincubating SNU‑1 cells with 3‑methyladenine, a cell‑autophagy inhibitor, significantly alleviated the effects of Nar in promoting cell apoptosis and cleaved caspase 3 expression. It was concluded that Nar promoted SNU‑1 cell apoptosis via blocking the PI3K/AKT signaling pathway and activating cell autophagy.

31 May 2022 in Research Square
Verified
Preprint
Open access
PDF file
SWShixun Wu
Shixun Wu
SLShizhang Liu
Shizhang Liu
MLMing Ling
Ming Ling
MHMinggang Huang
Minggang Huang
ZLZhe Liu
Zhe Liu
XDXianglong Duan
Xianglong Duan
To investigate a novel approach of establishment for transverse pedicle angle (TPA) of lower lumbar spine using preoperative digital radiography(DR). CT dataset of the lower lumbar were reconstructed using MIMICS 17.0 software, then imported into the 3matic software for surgical simulation and anatomical parameters measurement. Mathematical algorithm of TPA based on Pythagorean theorem was established, all obtained data was analysised by SPSS software. CT dataset from 66 samples were reconstructed as digital model of lower lumbar vertebrate(L3-L5), AP length / estimated lateral length for L3 between right and left were significant statistically(P = 0.015, P = 0.005). AP length of right for L4 was smaller than that of left after Paired t-test was executed(P = 0.006). Both width of pedicle and length of pedicle (P2C1) are consistent with TPA(L3 < L4 < L5). No statistical differences in TAN-TPA and DR-TPA compared with real TPA. ICC for real TPA and DR-TPA within L3 is good reliability, ICC for real TPA and DR-TPA within both L4 and L5 are moderate reliability. Our novel approach can be well considered as a reliable way to determine the transverse pedicle angle from routine DR, width and length of pedicle within lumbar DR should be considered to determine the length and trajectory of screw during preoperation planning.

3 June 2022 in Orthopaedic Surgery
Verified
Journal Article
Open access
SWShi‐Xun Wu
Shi‐Xun Wu
SLShi‐Zhang Liu
Shi‐Zhang Liu
MLMing Ling
Ming Ling
YCYan‐Hui Che
Yan‐Hui Che
XTXin Tian
Xin Tian
ZYZhi Yi
Zhi Yi
Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE (R) total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub-data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67 degrees +/- 2.87 degrees, the average amount of bone resection was 12.13 +/- 1.86 cm(3), the mid-anterior distance was 1.72 +/- 0.19 cm, the mid-posterior distance was 2.00 +/- 0.19 cm, the ratio of mid-anterior to mid-posterior was 0.87, the mid-medial distance was 1.26 +/- 0.17 cm, the mid-lateral distance was 1.19 +/- 0.16 cm, and the ratio of mid-medial to mid-lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 +/- 0.32 cm, the transverse diameter was 2.46 +/- 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid-anterior distance was strongly negatively correlated with age, the mid-anterior distance and the amount of bone resection, the mid-medial distance and the amount of bone resection, the mid-lateral distance and the amount of bone resection, the mid-lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.