15 September 2022 in Physics in Medicine & Biology
Objective. Obtaining the intrinsic dose distributions in particle therapy is a challenging problem that needs to be addressed by imaging algorithms to take advantage of secondary particle detectors. In this work, we investigate the utility of deep learning methods for achieving direct mapping from detector data to the intrinsic dose distribution. Approach. We performed Monte Carlo simulations using GATE/Geant4 10.4 simulation toolkits to generate a dataset using human CT phantom irradiated with high-energy protons and imaged with compact in-beam PET for realistic beam delivery in a single-fraction (∼2 Gy). We developed a neural network model based on conditional generative adversarial networks to generate dose maps conditioned on coincidence distributions in the detector. The model performance is evaluated by the mean relative error, absolute dose fraction difference, and shift in Bragg peak position. Main results. The relative deviation in the dose and range of the distributions predicted by the model from the true values for mono-energetic irradiation between 50 and 122 MeV lie within 1% and 2%, respectively. This was achieved using 105 coincidences acquired five minutes after irradiation. The relative deviation in the dose and range for spread-out Bragg peak distributions were within 1% and 2.6% uncertainties, respectively. Significance. An important aspect of this study is the demonstration of a method for direct mapping from detector counts to dose domain using the low count data of compact detectors suited for practical implementation in particle therapy. Including additional prior information in the future can further expand the scope of our model and also extend its application to other areas of medical imaging.
31 May 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Proton therapy for cancer treatment has a precise dose deposition capability owing to the nature of the interactions of heavy charge particles with matter resulting in a Bragg Peak. Uncertainties in the proton range can limit the scope of proton therapy. Academia Sinica PET employs a modular design for In-beam detection using SiPMs and crystals read out by STiC asic for range verification. In this work we report the depth distribution of the positron emitters from a PMMA sample irradiated with 130 MeV protons at the Chang Gung Memorial Hospital measured using a compact 32-channel setup. The timing capabilities of this system are assessed and presented. The depth dependence of the positron activity measured using coincidences agrees well with the Geant4 simulated distributions. Using a multi-exponential fit function we estimate and compare the relative amounts of different positron emitting isotopes with the relative cross sections. The application of this method can be useful to estimate the anatomical changes between different treatment sessions. The modular design of the AS-PET currently under development at Academia Sinica is presented and the simulated images of the reconstructed positron activity for the palm sized modules are used to assess the range verification capability.