Chih-Hsun Lin

Chih-Hsun Lin

Auto-generated profile, based on publicly available information

Chih-Hsun Lin

Academia Sinica

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in The Astronomical Journal
Verified
Journal Article
Closed access
CYChien-Ying Yang
Chien-Ying Yang
YCYi-Chi Chang
Yi-Chi Chang
HLHung-Hsiang Liang
Hung-Hsiang Liang
CCChe-Yen Chu
Che-Yen Chu
JHJr-Yue Hsiang
Jr-Yue Hsiang
HCHsiang-Kuang Chang
Hsiang-Kuang Chang
Instruments flown on CubeSats are small. Meaningful applications of CubeSats in astronomical observations rely on the choice of a particular subject that is feasible for CubeSats. Here we report the result of a feasibility study for observing gamma-ray polarization from Cygnus X-1 using a small Compton polarimeter on board a 3U CubeSat. Silicon detectors and cerium bromide scintillators were employed in the instrument models that we discuss in this study. Through Monte Carlo simulations with a Geant4-based MEGAlib package, we found that, with a 10 Ms on-axis, zenith-direction observation in a low-inclination, low-altitude, Earth-orbit radiation background environment, the minimum detectable polarization degree can be down to about 10% in 160–250 keV, 20% in 250–400 keV, and 65% in 400–2000 keV. A 3U CubeSat dedicated to observing Cygnus X-1 can therefore yield useful information on the polarization state of gamma-ray emissions from the brightest persistent X-ray black hole binary in the sky.

1 July 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
YIY. Inoue
Y. Inoue
BHB. H. Hsieh
B. H. Hsieh
KCK. H. Chen
K. H. Chen
YCY. K. Chu
Y. K. Chu
KIK. Ito
K. Ito
TYT. Yokozawa
T. Yokozawa
The Kamioka Gravitational wave detector (KAGRA) cryogenic gravitational-wave observatory has commenced joint observations with the worldwide gravitational wave detector network. Precise calibration of the detector response is essential for accurately estimating parameters of gravitational wave sources. A photon calibrator is a crucial calibration tool used in laser interferometer gravitational-wave observatory, Virgo, and KAGRA, and it was utilized in joint observation 3 with GEO600 in Germany in April 2020. In this paper, KAGRA implemented three key enhancements: a high-power laser, a power stabilization system, and remote beam position control. KAGRA employs a 20 W laser divided into two beams that are injected onto the mirror surface. By utilizing a high-power laser, the response of the detector at kHz frequencies can be calibrated. To independently control the power of each laser beam, an optical follower servo was installed for power stabilization. The optical path of the photon calibrator’s beam positions was controlled using pico-motors, allowing for the characterization of the detector’s rotation response. Additionally, a telephoto camera and quadrant photodetectors were installed to monitor beam positions, and beam position control was implemented to optimize the mirror response. In this paper, we discuss the statistical errors associated with the measurement of relative power noise. We also address systematic errors related to the power calibration model of the photon calibrator and the simulation of elastic deformation effects using finite element analysis. Ultimately, we have successfully reduced the total systematic error from the photon calibrator to 2.0%.

8 June 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TTTomonori Takahashi
Tomonori Takahashi
KAKazuya Aoki
Kazuya Aoki
SASakiko Ashikaga
Sakiko Ashikaga
WCWen-Chen Chang
Wen-Chen Chang
EHEitaro Hamada
Eitaro Hamada
SYSatoshi Yokkaichi
Satoshi Yokkaichi
J-PARC E16 is an experiment to examine the origin of hadron mass through a systematic measurement of spectral changes of vector mesons in nuclei. The measurement of e + e - pairs from the decay of vector mesons will provide the information of the partial restoration of the chiral symmetry in a normal nuclear density. To resolve a pulse pile-up and achieve good discrimination of e + and e - from the background of a reaction rate of an order of 10 MHz, the data acquisition (DAQ) system uses waveform sampling chips of APV25 and DRS4. The trigger rate and data rate are expected to be 1 kHz and 120-330 MiB/s, respectively. The DAQ system for readout of APV25 and DRS4 were developed, where events were synchronized by common trigger and tag data. The first commissioning in beam, called Run-0a, was performed in June 2020 with about 1/4 of the designed setup. The DAQ worked with a trigger rate of 300 Hz in the Run-0a and the main bottleneck was a large data size of APV25. Further optimization of the DAQ system will improve the performance.

14 April 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Jakub RipaJakub Ripa
Jakub Ripa
MDMarianna Dafčíková
Marianna Dafčíková
PKPavel Kosík
Pavel Kosík
FMFilip Münz
Filip Münz
MOMasanori Ohno
Masanori Ohno
CTChe-Chih Tsao
Che-Chih Tsao

31 May 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
MNMythra Varun Nemallapudi
Mythra Varun Nemallapudi
ARAtiq Rahman
Atiq Rahman
ACAugustine Ei-Fong Chen
Augustine Ei-Fong Chen
SLShih-Chang Lee
Shih-Chang Lee
CLChih-Hsun Lin
Chih-Hsun Lin
CCCheng-Ying Chou
Cheng-Ying Chou
Proton therapy for cancer treatment has a precise dose deposition capability owing to the nature of the interactions of heavy charge particles with matter resulting in a Bragg Peak. Uncertainties in the proton range can limit the scope of proton therapy. Academia Sinica PET employs a modular design for In-beam detection using SiPMs and crystals read out by STiC asic for range verification. In this work we report the depth distribution of the positron emitters from a PMMA sample irradiated with 130 MeV protons at the Chang Gung Memorial Hospital measured using a compact 32-channel setup. The timing capabilities of this system are assessed and presented. The depth dependence of the positron activity measured using coincidences agrees well with the Geant4 simulated distributions. Using a multi-exponential fit function we estimate and compare the relative amounts of different positron emitting isotopes with the relative cross sections. The application of this method can be useful to estimate the anatomical changes between different treatment sessions. The modular design of the AS-PET currently under development at Academia Sinica is presented and the simulated images of the reconstructed positron activity for the palm sized modules are used to assess the range verification capability.

26 November 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YIY. Igarashi
Y. Igarashi
MDM. Dozono
M. Dozono
RHR. Honda
R. Honda
NKN. Kobayashi
N. Kobayashi
CLC. S. Lin
C. S. Lin
TTT. N. Takahashi
T. N. Takahashi
Detector systems in modern nuclear and particle physics experiments must handle numerous channels and high data throughput. Furthermore, the requirements for trigger systems have become increasingly complex, necessitating effective decision-making processes. Streaming readout and software-based triggering on distributed computers present a natural solution to these challenges, owing to recent technological advances. Therefore, we developed a widely usable streaming data acquisition (DAQ) system based on FairMQ and the Redis key value database. To address this challenge, we have developed a streaming DAQ system that handles continuous data flow and complex triggering in the software. The DAQ system is relatively simple and can be deployed and operated by a small team. It operates through the cooperation of multiple elementary functional processes, with connections automatically established based on port names, service names, and connection information stored in a database. We applied this DAQ system to actual detector systems, including the RCNP Grand Raiden spectrometer and the J-PARC E50 detector system beam test, utilizing streaming readout and online software triggering. The two detector systems, consisting of plastic scintillation counters and drift chambers, were read out by a field-programmable gate array based streaming readout time-to-digital converter and distributed synchronized clock, where the charge information was obtained from the time-over-threshold. The streaming DAQ system performed effectively, including the software trigger, on 24-Core server computers. The software component of the DAQ system was also applied to a triggered DAQ system for a cylindrical drift chamber for the J-PARC COMET experiment, where it demonstrated sufficient performance. We further demonstrated the streaming-capable DAQ system and its practical application, with a focus primarily on the software aspect.