Room‐temperature (RT) gas sensitivity of morphology‐controlled free‐standing hollow aluminum‐doped zinc oxide (AZO) nanofibers for NO2 gas sensors is presented. The free‐standing hollow nanofibers are fabricated using a polyvinylpyrrolidone fiber template electrospun on a copper electrode frame followed by radio‐frequency sputtering of an AZO thin overlayer and heat treatment at 400 °C to burn off the polymer template. The thickness of the AZO layer is controlled by the deposition time. The gas sensor based on the hollow nanofibers demonstrates fully recoverable n‐type RT sensing of low concentrations of NO2 (0.5 ppm). A gas sensor fabricated with Al2O3‐filled AZO nanofibers exhibits no gas sensitivity below 75 °C. The gas sensitivity of a sensor is determined by the density of molecules above the minimum energy for adsorption, collision frequency of gas molecules with the surface, and available adsorption sites. Based on finite‐difference time‐domain simulations, the RT sensitivity of hollow nanofiber sensors is ascribed to the ten times higher collision frequency of NO2 molecules confined inside the fiber compared to the outer surface, as well as twice the surface area of hollow nanofibers compared to the filled ones. This approach might lead to the realization of RT sensitive gas sensors with 1D nanostructures.
Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) is one of the most promising candidate materials for flexible thermoelectric generators. We report changes in morphological, electrical, and thermoelectric properties of strained PEDOT:PSS thin films treated with solvents, including H2SO4, MeOH, and polyethylene glycol (PEG). The stretching creates macroscopic cracks on the thin film surface and microscopically change the domain structure from a dense network to an isolated state. With increasing strain, short, fine cracks at small strains propagate into long, thick cracks. The H2SO4 treatment makes PEDOT:PSS very brittle even at ∼5% strain, whereas PEG improves the stretchability of PEDOT:PSS up to 50%. Stretching reduces the electrical conductivity of solvent-treated samples, which agrees well with the decreased hole concentration of strained PEDOT:PSS, as confirmed by ultraviolet photoemission spectroscopy. In contrast, the Seebeck coefficient (S) of the strained PEDOT:PSS thin films increases. The PEG sample shows the highest S, and thus exhibits an enhanced power factor (PF) with strain, while other solvent treatments reduce PF. To the best of our knowledge, this is the first report on the strain-induced enhancement of S and thermoelectric PF of PEDOT:PSS.