Anuj J. Kapadia

Anuj J. Kapadia

Auto-generated profile, based on publicly available information

Anuj J. Kapadia

Oak Ridge National Laboratory

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
EAEhsan Abadi
Ehsan Abadi
BHBrian Harrawood
Brian Harrawood
SSShobhit Sharma
Shobhit Sharma
AKAnuj Kapadia
Anuj Kapadia
WSWilliam P. Segars
William P. Segars
ESEhsan Samei
Ehsan Samei
The purpose of this study was to develop a CT simulation platform that is: 1) compatible with voxel-based computational phantoms; 2) capable of modeling the geometry and physics of commercial CT scanners; and 3) computationally efficient. Such a simulation platform is designed to enable the virtual evaluation and optimization of CT protocols and parameters for achieving a targeted image quality while reducing radiation dose. Given a voxelized computational phantom and a parameter file describing the desired scanner and protocol, the developed platform DukeSim calculates projection images using a combination of ray-tracing and Monte Carlo techniques. DukeSim includes detailed models for the detector quantum efficiency, quantum and electronic noise, detector crosstalk, subsampling of the detector and focal spot areas, focal spot wobbling, and the bowtie filter. DukeSim was accelerated using GPU computing. The platform was validated using physical and computational versions of a phantom (Mercury phantom). Clinical and simulated CT scans of the phantom were acquired at multiple dose levels using a commercial CT scanner (Somatom Definition Flash; Siemens Healthcare). The real and simulated images were compared in terms of image contrast, noise magnitude, noise texture, and spatial resolution. The relative error between the clinical and simulated images was less than 1.4%, 0.5%, 2.6%, and 3%, for image contrast, noise magnitude, noise texture, and spatial resolution, respectively, demonstrating the high realism of DukeSim. The runtime, dependent on the imaging task and the hardware, was approximately 2-3 minutes per rotation in our study using a computer with 4 GPUs. DukeSim, when combined with realistic human phantoms, provides the necessary toolset with which to perform large-scale and realistic virtual clinical trials in a patient and scanner-specific manner.

19 April 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
EAEhsan Abadi
Ehsan Abadi
WSWilliam P. Segars
William P. Segars
GSGregory M. Sturgeon
Gregory M. Sturgeon
BHBrian Harrawood
Brian Harrawood
AKAnuj Kapadia
Anuj Kapadia
ESEhsan Samei
Ehsan Samei
The purpose of this paper was to develop detailed and realistic models of the cortical and trabecular bones in the spine, ribs, and sternum and incorporate them into the library of virtual human phantoms [extended cardiac-torso (XCAT)]. Cortical bone was modeled by 3-D morphological erosion of XCAT homogenously defined bones with an average thickness measured from the computed tomography (CT) dataset upon which each individual XCAT phantom was based. The trabecular texture was modeled using a power law synthesis algorithm, where the parameters were tuned using high-resolution anatomical images of the Human Visible Female. The synthesized bone textures were added into the XCAT phantoms. To qualitatively evaluate the improved realism of the bone modeling, CT simulations of the XCAT phantoms were acquired with and without the textured bone modeling. The 3-D power spectrum of the anatomical images exhibited a power law behavior (R 2 = 0.84), as expected in fractal and porous textures. The proposed texture synthesis algorithm was able to synthesize textures emulating real anatomical images, where the simulated CT images with the prototyped bones were more realistic than those simulated with the original XCAT models. Incorporating intraorgan structures, the “textured” phantoms are envisioned to be used to conduct virtual clinical trials in the context of medical imaging in cases, where the actual trials are infeasible due to the lack of ground truth, cost, or potential risks to the patients.

26 June 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CFCarey E Floyd
Carey E Floyd
JBJanelle E Bender
Janelle E Bender
ASAmy C Sharma
Amy C Sharma
AKAnuj Kapadia
Anuj Kapadia
JXJessie Xia
Jessie Xia
CHCalvin Howell
Calvin Howell
Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.

8 February 2008 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
AKAnuj J. Kapadia
Anuj J. Kapadia
ASAmy C. Sharma
Amy C. Sharma
GTGeorgia D. Tourassi
Georgia D. Tourassi
JBJanelle E. Bender
Janelle E. Bender
CHCalvin R. Howell
Calvin R. Howell
CFCarey E. Floyd
Carey E. Floyd
Neutron stimulated emission computed tomography (NSECT) is being developed as a non-invasive spectroscopic imaging technique to determine element concentrations in the human body. NSECT uses a beam of fast neutrons that scatter inelastically from atomic nuclei in tissue, causing them to emit characteristic gamma photons that are detected and identified using an energy-sensitive gamma detector. By measuring the energy and number of emitted gamma photons, the system can determine the elemental composition of the target tissue. Such determination is useful in detecting several disorders in the human body that are characterized by changes in element concentration, such as breast cancer. In this paper we describe our experimental implementation of a prototype NSECT system for the diagnosis of breast cancer and present experimental results from sensitivity studies using this prototype. Results are shown from three sets of samples: (a) excised breast tissue samples with unknown element concentrations, (b) a multi-element calibration sample used for sensitivity studies, and (c) a small-animal specimen, to demonstrate detection ability from in-vivo tissue. Preliminary results show that NSECT has the potential to detect elements in breast tissue. Several elements were identified common to both benign and malignant samples, which were confirmed through neutron activation analysis (NAA). Statistically significant differences were seen for peaks at energies corresponding to 37Cl, 56Fe, 58Ni, 59Co, 79Br and 87Rb. The spectrum from the small animal specimen showed the presence of 12C from tissue, from bone, and elements 39K, 27Al, 37Cl, 56Fe, 68Zn and 25Mg. Threshold sensitivity for the four elements analyzed was found to range from 0.3 grams to 1 gram, which is higher than the microgram sensitivity required for cancer detection. Patient dose levels from NSECT were found to be comparable to those of screening mammography.

15 December 2023 in Applied Geography
Verified
Journal Article
Open access
APAlina Peluso
Alina Peluso
JTJoseph Tuccillo
Joseph Tuccillo
KSKevin Sparks
Kevin Sparks
AKAnuj Kapadia
Anuj Kapadia
HHHeidi A. Hanson
Heidi A. Hanson

1 October 2022
Verified
Conference Paper
Closed access
SWSean R. Wilkinson
Sean R. Wilkinson
GEGreg Eisenhauer
Greg Eisenhauer
AKAnuj J. Kapadia
Anuj J. Kapadia
KKKathryn Knight
Kathryn Knight
JLJeremy Logan
Jeremy Logan
MWMatthew Wolf
Matthew Wolf
The FAIR principles for scientific data (Findable, Accessible, Interoperable, Reusable) are also relevant to other digital objects such as research software and scientific workflows that operate on scientific data. The FAIR principles can be applied to the data being handled by a scientific workflow as well as the processes, software, and other infrastructure which are necessary to specify and execute a workflow. The FAIR principles were designed as guidelines, rather than rules, that would allow for differences in standards for different communities and for different degrees of compliance. There are many practical considerations which impact the level of FAIR-ness that can actually be achieved, including policies, traditions, and technologies. Because of these considerations, obstacles are often encountered during the workflow lifecycle that trace directly to shortcomings in the implementation of the FAIR principles. Here, we detail some cases, without naming names, in which data and workflows were Findable but otherwise lacking in areas commonly needed and expected by modern FAIR methods, tools, and users. We describe how some of these problems, all of which were overcome successfully, have motivated us to push on systems and approaches for fully FAIR workflows.