Dennis Albert

Dennis Albert

Auto-generated profile, based on publicly available information

Dennis Albert

OMICRON electronics GmbH, Klaus, Austria

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2022 in Space Weather
Verified
Journal Article
Open access
PDF file
DAD. Albert
D. Albert
PSP. Schachinger
P. Schachinger
RBR. L. Bailey
R. L. Bailey
HRHerwig Renner
Herwig Renner
GAG. Achleitner
G. Achleitner
Geomagnetically induced currents (GICs), a result of solar wind interaction with the Earth's magnetic field and the resistive ground, are known to flow in power transmission grids, where they can lead to transformer damage and grid operation problems. In this study we present an analysis of five years of continuous GIC measurements in transformer neutral points in Austria. Seven self‐designed stand‐alone measurement systems are currently installed in the Austrian 220 and 380 kV transmission levels, measuring currents up to 25 A. We identify recurrent geomagnetic activity in the measurements, and also find man‐made sources of low frequency currents using frequency analysis. In order to support the transmission grid operators, two GIC simulation approaches are used to simulate GICs in the power grid. The first model uses measurements to derive the sensitivity of the location to northward and eastward geoelectric field components (which requires no detailed grid data), and the second model uses the detailed grid model to compute GICs from a geoelectric field. We evaluate two geomagnetic storms from September 2017 and May 2021 to discuss the effects of GICs on the power transmission grid and its assets.

15 June 2022 in IEEE Access
Verified
Journal Article
Open access
SZSergey E. Zirka
Sergey E. Zirka
DADennis Albert
Dennis Albert
YMYuriy I. Moroz
Yuriy I. Moroz
HRHerwig Renner
Herwig Renner
This paper is devoted to improvements of the low-frequency topological model of a three-legged stacked-core transformer. It is shown that $B-H$ hysteresis loops employed in the transformer model and $\Psi -i$ curves measured at transformer terminals are quite different in shape. A distinction is made between transformer modeling at moderate and deep saturations, separated conditionally by the level of technical saturation (near 2 Tesla) typical for grain-oriented steels. In the former case, in addition to the magnetic coupling of different phase windings through the core, an important part is played by air gaps at core joints. It is found that the effective gap length depends on the instantaneous magnetic flux and this dependence is proposed to implement by a variable inductance. It is shown that regardless of the core saturation depth, an important role in the transformer modeling belongs to the distribution of the zero-sequence path between all three phases. In addition to accurate replications of the special purpose saturation test, the modeled results are in a close agreement with positive- and zero sequence data measured on a 50 kVA transformer, as well as with the measured inrush currents.

11 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JMJohannes Mandl
Johannes Mandl
PTPhilipp Trampitsch
Philipp Trampitsch
PSPhilipp Schachinger
Philipp Schachinger
DADennis Albert
Dennis Albert
RKReinhard Klambauer
Reinhard Klambauer
ABAlexander Bergmann
Alexander Bergmann
Preserving the stable operation and proper functionality of the electric power grid is of utmost importance. Integral grid components such as power transformers are negatively affected by occurring disturbances. In particular, the time course and distribution on the different phases of direct currents within the transmission grid, among them geomagnetically induced currents, is of great interest. In this paper, we report on the development of a fiber optic current sensor exploiting the Faraday effect intended to observe these direct currents on all three phases of a high-voltage power grid. The proposed low-cost sensor is constructed with an adjustable phase retarder and a single-mode sensing fiber. A linear current relationship for direct currents down to 1A was observed. From the sensor signal, the presence of a direct current bias superimposed on an alternating current can be identified. Simulations based on a Jones formalism model provided application limits of the single-mode sensing fiber. Furthermore, we developed a calibration procedure to counteract temperature-induced variations of the sensor scale factor within the fiber-optic coil and achieve a maximum current error of 0.5% down to a rated current of 5A in a range from 15-65°C.

28 February 2023 in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Verified
Journal Article
Open access
PDF file
DADennis Albert
Dennis Albert
LDLukas Daniel Domenig
Lukas Daniel Domenig
PSPhilipp Schachinger
Philipp Schachinger
KRKlaus Roppert
Klaus Roppert
HRHerwig Renner
Herwig Renner
Purpose: The purpose of this paper is to investigate the applicability of a direct current (DC) hysteresis measurement on power transformer terminals for the subsequent hysteresis model parametrization in transformer grey box topology models. Design/methodology/approach: Two transformer topology models with two different hysteresis models are used together with a DC hysteresis measurement via the power transformer terminals to parameterize the hysteresis models by means of an optimization. The calculated current waveform with the derived model in the transformer no-load condition is compared to the measured no-load current waveforms to validate the model. Findings: The proposed DC hysteresis measurement via the power transformer terminals is suitable to parametrize two hysteresis models implemented in transformer topology models to calculate the no-load current waveforms. Originality/value: Different approaches for the measurement and utilization of transformer terminal measurements for the hysteresis model parametrization are discussed in literature. The transformer topology models, derived with the presented approach, are able to reproduce the transformer no-load current waveform with acceptable accuracy.

2 December 2024 in e+i Elektrotechnik und Informationstechnik
Verified
Journal Article
Closed access
PDF file
DADennis Albert
Dennis Albert
LDLukas Domenig
Lukas Domenig
NSNicolai Schwartze
Nicolai Schwartze
ZHZerina Hadzic
Zerina Hadzic
KRKlaus Roppert
Klaus Roppert

11 June 2025 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Open access
ASAlexander Sauseng
Alexander Sauseng
ARAlice Reinbacher‐Köstinger
Alice Reinbacher‐Köstinger
DADennis Albert
Dennis Albert
PHPeter Hamberger
Peter Hamberger
MKManfred Kaltenbacher
Manfred Kaltenbacher
KRKlaus Roppert
Klaus Roppert
Incorporating the magnetic core material in a lumped‐element transformer model generally results in a nonlinear network with hysteresis. Such a network can be solved subsequently in the time domain using time‐stepping methods. The transient response reveals the inrush, whose decay time is generally enormous compared to the time constant of the excitation period (e.g., 20 ms for a voltage source with a frequency of 50 Hz). To directly obtain the steady‐state solution of the lumped‐element transformer model, the harmonic balance method is superior to such an analysis, because it is a frequency domain approach inherently yielding the steady‐state solution. The great advantage of harmonic balance is that it can handle nonlinearities by evaluating them in the time domain and using their spectral components in the frequency domain. This paper theoretically derives the harmonic balance algorithm and further solves a lumped‐element single‐phase transformer model based on a mutual and leakage flux approach utilizing Hopkinson 's law. The nonlinear network element is represented by an energy‐based dry friction‐like hysteresis model depicting the core material of the transformer. The hysteresis parameters are fitted to no‐load current measurements, and the no‐load case, the short‐circuit case, and a chosen load case are simulated and compared to measurements. The algorithm's efficiency in terms of iterations and computational time is demonstrated by simulating with several excitation frequencies and for several load cases and comparing it to a transient analysis revealing the transformer's inrush.