Herwig Renner

Prof. Dr. Herwig Renner

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2002
Verified
Conference Paper
Closed access
HRHerwig Renner
Herwig Renner
MSM. Sakulin
M. Sakulin

24 January 2022 in Space Weather
Verified
Journal Article
Open access
PDF file
DAD. Albert
D. Albert
PSP. Schachinger
P. Schachinger
RBR. L. Bailey
R. L. Bailey
HRHerwig Renner
Herwig Renner
GAG. Achleitner
G. Achleitner
Geomagnetically induced currents (GICs), a result of solar wind interaction with the Earth's magnetic field and the resistive ground, are known to flow in power transmission grids, where they can lead to transformer damage and grid operation problems. In this study we present an analysis of five years of continuous GIC measurements in transformer neutral points in Austria. Seven self‐designed stand‐alone measurement systems are currently installed in the Austrian 220 and 380 kV transmission levels, measuring currents up to 25 A. We identify recurrent geomagnetic activity in the measurements, and also find man‐made sources of low frequency currents using frequency analysis. In order to support the transmission grid operators, two GIC simulation approaches are used to simulate GICs in the power grid. The first model uses measurements to derive the sensitivity of the location to northward and eastward geoelectric field components (which requires no detailed grid data), and the second model uses the detailed grid model to compute GICs from a geoelectric field. We evaluate two geomagnetic storms from September 2017 and May 2021 to discuss the effects of GICs on the power transmission grid and its assets.

15 February 2018 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
KYKoji Yamashita
Koji Yamashita
HRHerwig Renner
Herwig Renner
SVSergio Martinez Villanueva
Sergio Martinez Villanueva
GLGustav Lammert
Gustav Lammert
Petros AristidouPetros Aristidou
Petros Aristidou
TCThierry Van Cutsem
Thierry Van Cutsem
Dynamic simulations have played an important role in assessing the power system dynamic studies. The appropriate numerical model is the key to obtain correct dynamic simulation results. In addition, the appropriate model including the selection of the individual model component (such as protections, controls, and capabilities) is different depending on the type of phenomena to be observed or examined. However, the proper selection of the model is not an easy task, especially for inverter-based generators (IBGs). Considerable industry experience concerning power system dynamic studies and the dynamics of the IBGs is required for the proper selection of the IBG model. The established CIGRE C4/C6.35/CIRED joint working group (JWG) has gathered a wide variety of experts, which fully cover the required industry experience. The JWG provides the guidance on the model selection for analyzing the phenomena, such as frequency deviation, large voltage deviation, and long-term voltage deviation, individually. This helps to reduce the computational burden, as well as it clarifies the required characteristics/functions that should be represented for the power system dynamic studies with the IBGs.

15 June 2022 in IEEE Access
Verified
Journal Article
Open access
SZSergey E. Zirka
Sergey E. Zirka
DADennis Albert
Dennis Albert
YMYuriy I. Moroz
Yuriy I. Moroz
HRHerwig Renner
Herwig Renner
This paper is devoted to improvements of the low-frequency topological model of a three-legged stacked-core transformer. It is shown that $B-H$ hysteresis loops employed in the transformer model and $\Psi -i$ curves measured at transformer terminals are quite different in shape. A distinction is made between transformer modeling at moderate and deep saturations, separated conditionally by the level of technical saturation (near 2 Tesla) typical for grain-oriented steels. In the former case, in addition to the magnetic coupling of different phase windings through the core, an important part is played by air gaps at core joints. It is found that the effective gap length depends on the instantaneous magnetic flux and this dependence is proposed to implement by a variable inductance. It is shown that regardless of the core saturation depth, an important role in the transformer modeling belongs to the distribution of the zero-sequence path between all three phases. In addition to accurate replications of the special purpose saturation test, the modeled results are in a close agreement with positive- and zero sequence data measured on a 50 kVA transformer, as well as with the measured inrush currents.

11 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZZZiqian Zhang
Ziqian Zhang
CGCihan Gercek
Cihan Gercek
HRHerwig Renner
Herwig Renner
ARAngèle Reinders
Angèle Reinders
LFLothar Fickert
Lothar Fickert
This article presents an in-situ comparative analysis and power quality tests of a newly developed photovoltaic charging system for e-bikes. The various control methods of the inverter are modeled and a single-phase grid-connected inverter is tested under different conditions. Models are constituted for two current control methods; the proportional resonance and the synchronous rotating frames. In order to determine the influence of the control parameters, the system is analyzed analytically in the time domain as well as in the frequency domain by simulation. The tests indicated the resonance instability of the photovoltaic inverter. The passivity impedance-based stability criterion is applied in order to analyze the phenomenon of resonance instability. In conclusion, the phase-locked loop (PLL) bandwidth and control parameters of the current loop have a major effect on the output admittance of the inverter, which should be adjusted to make the system stable.

9 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
SPStefan Polster
Stefan Polster
JDJohannes Deschler
Johannes Deschler
HRHerwig Renner
Herwig Renner
ABAurelie Bocquel
Aurelie Bocquel
MJMartin Janssen
Martin Janssen
The green energy transition of electrical energy production is leading to an increasing share of total energy production for volatile renewable energy sources, mainly wind and solar power. To handle this volatile production, flexible and efficient energy storage is required. The development of high-power converters has enabled the generation of variable-speed pumped hydro storage power plants, combining the so-far-unequalled energy storage capacity of classical pumped-storage hydro power plants and the recently increased operation requirements. The introduction of large-scale converters has led to new challenges in the overall design of power plant systems. This paper intended to take a closer look at a large-scale converter-fed synchronous generator, especially the distribution of the current and voltage harmonics caused by the converter in the implemented generation system. Thereby, holistic design considerations for an ideal loss distribution as well as possible measures to limit the effects of harmonic coupling at the generator shaft and bearings are discussed. Furthermore, basic considerations of harmonic emission to the connected network are described. These topics are addressed by analyzing on-site measurements at an 85 MVA converter-fed synchronous generator with a voltage source inverter, underpinned with the theoretical background.