Denice van Herwerden

Denice van Herwerden

Auto-generated profile, based on publicly available information

Denice van Herwerden

University of Amsterdam

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Analytical Chemistry
Verified
Journal Article
Open access
TBTijmen Bos
Tijmen Bos
JBJim Boelrijk
Jim Boelrijk
SMStef R. A. Molenaar
Stef R. A. Molenaar
BVBrian van ’T Veer
Brian van ’T Veer
LNLeon E. Niezen
Leon E. Niezen
BPBob W. J. Pirok
Bob W. J. Pirok
The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesian-optimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).

20 June 2024 in JACS Au
Verified
Journal Article
Open access
Saer SamanipourSaer Samanipour
Saer Samanipour
LBLeon Patrick Barron
Leon Patrick Barron
DHDenice van Herwerden
Denice van Herwerden
APAntonia Praetorius
Antonia Praetorius
KTKevin V. Thomas
Kevin V. Thomas
JOJake William O’brien
Jake William O’brien
Around two-thirds of chronic human disease can not be explained by genetics alone. The Lancet Commission on Pollution and Health estimates that 16% of global premature deaths are linked to pollution. Additionally, it is now thought that humankind has surpassed the safe planetary operating space for introducing human-made chemicals into the Earth System. Direct and indirect exposure to a myriad of chemicals, known and unknown, poses a significant threat to biodiversity and human health, from vaccine efficacy to the rise of antimicrobial resistance as well as autoimmune diseases and mental health disorders. The exposome chemical space remains largely uncharted due to the sheer number of possible chemical structures, estimated at over 1060 unique forms. Conventional methods have cataloged only a fraction of the exposome, overlooking transformation products and often yielding uncertain results. In this Perspective, we have reviewed the latest efforts in mapping the exposome chemical space and its subspaces. We also provide our view on how the integration of data-driven approaches might be able to bridge the identified gaps.

12 February 2022 in Chemometrics and Intelligent Laboratory Systems
Verified
Journal Article
Open access
DHDenice van Herwerden
Denice van Herwerden
JOJake W. O'BRien
Jake W. O'BRien
PCPhil M. Choi
Phil M. Choi
KTKevin V. Thomas
Kevin V. Thomas
PSPeter J. Schoenmakers
Peter J. Schoenmakers
Saer SamanipourSaer Samanipour
Saer Samanipour

24 August 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
BSBastian Schulze
Bastian Schulze
DHDenice van Herwerden
Denice van Herwerden
IAIan Allan
Ian Allan
LBLubertus Bijlsma
Lubertus Bijlsma
NENestor Etxebarria
Nestor Etxebarria
Saer SamanipourSaer Samanipour
Saer Samanipour
Non-target analysis (NTA) employing high-resolution mass spectrometry is a commonly applied approach for the detection of novel chemicals of emerging concern in complex environmental samples. NTA typically results in large and information-rich datasets that require computer aided (ideally automated) strategies for their processing and interpretation. Such strategies do however raise the challenge of reproducibility between and within different processing workflows. An effective strategy to mitigate such problems is the implementation of inter-laboratory studies (ILS) with the aim to evaluate different workflows and agree on harmonized/standardized quality control procedures. Here we present the data generated during such an ILS. This study was organized through the Norman Network and included 21 participants from 11 countries. A set of samples based on the passive sampling of drinking water pre and post treatment was shipped to all the participating laboratories for analysis, using one pre-defined method and one locally (i.e. in-house) developed method. The data generated represents a valuable resource (i.e. benchmark) for future developments of algorithms and workflows for NTA experiments.

24 February 2023 in Journal of Cheminformatics
Verified
Journal Article
Open access
PDF file
JBJim Boelrijk
Jim Boelrijk
DHDenice van Herwerden
Denice van Herwerden
BEBernd Ensing
Bernd Ensing
PFPatrick Forré
Patrick Forré
Saer SamanipourSaer Samanipour
Saer Samanipour
Non-target analysis combined with liquid chromatography high resolution mass spectrometry is considered one of the most comprehensive strategies for the detection and identification of known and unknown chemicals in complex samples. However, many compounds remain unidentified due to data complexity and limited number structures in chemical databases. In this work, we have developed and validated a novel machine learning algorithm to predict the retention index (r $$_i$$ i ) values for structurally (un)known chemicals based on their measured fragmentation pattern. The developed model, for the first time, enabled the predication of r $$_i$$ i values without the need for the exact structure of the chemicals, with an $$R^2$$ R 2 of 0.91 and 0.77 and root mean squared error (RMSE) of 47 and 67 r $$_i$$ i units for the NORMAN ( $$n=3131$$ n = 3131 ) and amide ( $$n=604$$ n = 604 ) test sets, respectively. This fragment based model showed comparable accuracy in r $$_i$$ i prediction compared to conventional descriptor-based models that rely on known chemical structure, which obtained an $$R^2$$ R 2 of 0.85 with an RMSE of 67.

29 September 2022 in Molecules
Verified
Journal Article
Open access
PDF file
FYFan Yang
Fan Yang
DHDenice van Herwerden
Denice van Herwerden
HPHugues Preud'homme
Hugues Preud'homme
Saer SamanipourSaer Samanipour
Saer Samanipour
High-resolution mass spectrometry is a promising technique in non-target screening (NTS) to monitor contaminants of emerging concern in complex samples. Current chemical identification strategies in NTS experiments typically depend on spectral libraries, chemical databases, and in silico fragmentation tools. However, small molecule identification remains challenging due to the lack of orthogonal sources of information (e.g., unique fragments). Collision cross section (CCS) values measured by ion mobility spectrometry (IMS) offer an additional identification dimension to increase the confidence level. Thanks to the advances in analytical instrumentation, an increasing application of IMS hybrid with high-resolution mass spectrometry (HRMS) in NTS has been reported in the recent decades. Several CCS prediction tools have been developed. However, limited CCS prediction methods were based on a large scale of chemical classes and cross-platform CCS measurements. We successfully developed two prediction models using a random forest machine learning algorithm. One of the approaches was based on chemicals’ super classes; the other model was direct CCS prediction using molecular fingerprint. Over 13,324 CCS values from six different laboratories and PubChem using a variety of ion-mobility separation techniques were used for training and testing the models. The test accuracy for all the prediction models was over 0.85, and the median of relative residual was around 2.2%. The models can be applied to different IMS platforms to eliminate false positives in small molecule identification.