11 February 2020 in IEEE Access
Acute cerebral ischemia is an important clinical disease that is usually detected by magnetic resonance imaging or computed tomography. The magnetic inductive phase shift (MIPS) is a new method for detecting cerebral diseases, which is non-invasive, miniaturized, and low-cost. A total of 25 rabbits were studied using a two-coil sensor with a 0.3-200 MHz frequency range, and all the subjects were measured for 1 hour. Based on the rabbit acute cerebral ischemia model, the rabbits were divided into unilateral ligation, bilateral ligation, and non-ligation groups. The results showed that the average MIPS values of the non-ligation, unilateral ligation, and bilateral ligation group were -0.195 ± 0.079°, -4.873 ± 1.042°, and -9.165 ± 2.862° respectively. MIPS distinguished different severities of cerebral ischemia in rabbits with statistical significance (p <; 0.05). Laser Doppler flowmetry (LDF) was used as the gold standard for collecting cerebral blood flow data. The strong correlation between the LDF measurements and the phase shift suggested that the phase shift reflects blood flow changes in the brain. Overall, these results suggest that the MIPS detection method has the potential to provide early detection of global cerebral ischemia. Furthermore, this method effectively distinguished different severities of cerebral ischemia.
21 August 2019 in Measurement Science and Technology
Intracranial hemorrhage (ICH), with extremely high morbidity and mortality, can only be detected by computed tomography (CT) and magnetic resonance imaging (MRI), which do not meet the requirements for bedside continuous monitoring and pre-hospital first aid. The magnetic induction method is a potential means of non-contact, non-invasive and continuous measurement of ICH. However, the current magnetic induction method measures the conductivity of the measured object. Because the conductivity of blood is only half that of cerebrospinal fluid (CSF) and the compensatory mechanism of CSF during hemorrhage, the sensitivity of measuring changes in intracranial conductivity to reflect the amount of bleeding is low. Since the permittivity of blood is far larger than that of other brain tissues, here a new method was used to determine the amounts of bleeding by measuring the head permittivity. The perturbed magnetic field produced by the measured head relative to the excitation magnetic field (Δ B/B ) was measured using an excitation coil and a receiving coil. The real part of Δ B/B , which includes permittivity information, was used to reflect the amount of bleeding. First, three solutions of alcohol, distilled water and blood (60 ml each) were detected. Then the rabbit heads were measured during the intracerebral blood injection. The injection amount was 2 ml at the rate of 2 ml/12 min. The real part data were extracted and evaluated. The physical experiments showed the real parts ranked as blood > distilled water > alcohol, which was consistent with the ranking of known permittivity among the three solutions. The animal experiments indicated the real part data of each animal changed little without blood injection, but slowly declined with increasing amount of injection. The real parts changed in the same trends among the ten animals. Analysis suggested the changing amounts of the real part data without injection were significantly smaller than those during the injection ( P < 0.05). The physical experiments confirm the real part of Δ B/B can differentiate the three solutions of alcohol, distilled water and blood. The animal experiment results also reveal the feasibility of using this method for intracranial hemorrhage measurement.
16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Currently, electrical capacitance tomography (ECT) is limited to time-differential imaging for monitoring dynamic alterations in cerebral hemorrhage. However, the inherent constraint of this approach renders it unsuitable for rapid hemorrhage detection, as it requires a reference measurement from a non-hemorrhaging brain. To address this limitation, this study proposes a novel approach of frequency-differential ECT (FDECT) for cerebral hemorrhage imaging in practice. The method entails identification of a frequency range wherein the permittivity variation of cerebral blood with frequency is much greater than the variation of other brain tissues. Within this identified range, two optimal frequencies are selected, and the permittivity difference at these two frequencies are used for imaging. With this method, cerebral hemorrhage is highlighted and other brain tissue is suppressed, thereby achieving the absolute distribution of cerebral hemorrhage and eliminating the need for non-hemorrhagic baseline data. Simulation results demonstrate that FDECT imaging quality correlates directly with the frequency-dependent permittivity difference between the target and background media, thereby validating FDECT's theoretical basis and highlighting the critical role of optimal frequency selection. Before conducting in vitro animal imaging, we analyzed the dielectric spectra of ex vivo sheep blood, pig fat, and pig brain tissue to identify the optimal frequency range for differentiating blood from these tissues. In vitro experiments confirmed that FDECT with the optimal frequencies effectively images blood within pig fat or brain tissue, contrasting with the suboptimal results from non-ideal frequencies. Although essential for FDECT success, optimal frequency pairing does not eliminate the higher noise levels in FDECT images, largely due to the background brain tissue's frequency-dependent dielectric characteristics. To mitigate this inherent limitation and improve imaging quality, we intend to implement a three-frequency FDECT approach, reducing background tissue interference.
21 March 2025 in Measurement Science and Technology
Microwave detection is a prospective method in promptly identifying strokes, thereby facilitating clinical intervention and improved prognosis. We aimed to explore the factors affecting microwave stroke detection results, including brain tissue volume, composition, and motion artifacts. Various brain tissue conductivities were simulated using different concentrations of sodium chloride solutions. Physical experiments were conducted utilizing a microwave detection system, with observations focused on changes in S-parameters. Eigenvalue changes are most notable for volume alterations and motion artifacts. The eigenvalues of motion artifacts and volumes exhibit distinctions at specific frequencies. At 1.85 GHz, differences in the imaginary part of depend solely on volume variation. The study reveals that volume changes and motion artifacts significantly impact microwave detection outcomes. Motion artifacts can be initially mitigated by targeting specific frequency points. The optimal eigenvalues for characterizing volume changes are differences in imaginary parts of , and real parts of differences in serve as the optimal feature for characterizing composition changes.
9 June 2026 in IEEE Transactions on Instrumentation and Measurement
Stroke is a leading cause of mortality and disability worldwide, with rapid diagnosis critical for effective intervention. Conventional imaging modalities such as CT and MRI are limited by their size, cost, and unsuitability for bedside or prehospital emergency use. This study presents a novel Superparamagnetic Iron Oxide Nanoparticles (SPIOs) based Magnetic Induction Tomography (SPIO-MIT) for non-invasive stroke-tracing imaging. Operating at an ultra-low excitation frequency of 3 kHz and a magnetic field strength below 1 mT, the system effectively suppresses background interference from biological tissues while enhancing sensitivity to SPIOs distribution. System performance was validated through phantom experiments featuring varied SPIOs positions, geometries, and concentration gradients, confirming accurate imaging of SPIOs with negligible response to low-conductivity substances. Complementary in vitro experiments embedding SPIO-blood mixtures in biological tissues demonstrated minimal background interference. In vivo experiments on a rabbit intracerebral hemorrhage model further confirmed precise localization of SPIOs injected into the brain, with detection sensitivity down to 1.2 mg of iron and an imaging diameter of 60 mm. In summary, the developed SPIO-MIT system enables sensitive, non-invasive spatial mapping of SPIOs. By combining the high sensitivity of magnetic particle imaging with the operational simplicity and biological safety of magnetic induction tomography, SPIO-MIT represents a promising technique for portable, bedside, and prehospital stroke diagnostics.