Jia Xu

Jia Xu

Auto-generated profile, based on publicly available information

Jia Xu

Department of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMaoting Zhang
Maoting Zhang
CZCheng Zhou
Cheng Zhou
LZLingxi Zeng
Lingxi Zeng
XHXianhua Hou
Xianhua Hou
JXJia Xu
Jia Xu
JSJian Sun
Jian Sun
Timely reperfusion of ischemic tissues and hemodynamic reconstruction are key to the treatment of acute ischemic stroke. The low temporal resolution of current imaging methods commonly used in clinical practice have the risk of diagnostic delay. In this study, a noninvasive cerebral blood flow (CBF) monitoring device was established based on inductive sensing technology, aiming at rapid and real-time assessment of ischemic tissue blood flow reperfusion to improve the treatment conditions and assess the prognostic outcome of acute ischemic stroke. The noninvasive CBF monitoring device was constructed using an inductive sensor and the LDC1612 evaluation module. Based on a homemade physical model of CBF pulsation and a healthy volunteer test, the depth and range of the sensor were evaluated by the time-domain amplitude and frequency-domain variation characteristics of resonant frequency. The monitoring results were processed using wavelet transform, high and low pass filtering, and cubic spline interpolation to remove the baseline and extract the CBF signal components. Based on the cardiogenic CBF pulsation mechanism, the periodic amplitude and area of CBF signals in resting and carbon dioxide inhalation states were extracted from healthy volunteers, and the feasibility of noninvasive monitoring of CBF by inductive sensing technology was evaluated. The experimental results showed that the method can evaluate the periodic pulsation of CBF and the changes of CBF in real-time with high accuracy. Thus, the present study verifies that the noninvasive CBF monitoring device based on inductive sensing technology can effectively detect the cardiac pulsations of CBF, which is expected to break the time window effect caused by the imaging examination and provide a new technology for noninvasive real-time monitoring of CBF perfusion changes.

11 February 2020 in IEEE Access
Verified
Journal Article
Open access
WZWei Zhuang
Wei Zhuang
WPWencai Pan
Wencai Pan
LXLin Xu
Lin Xu
JCJingbo Chen
Jingbo Chen
JXJia Xu
Jia Xu
MQMingxin Qin
Mingxin Qin
Acute cerebral ischemia is an important clinical disease that is usually detected by magnetic resonance imaging or computed tomography. The magnetic inductive phase shift (MIPS) is a new method for detecting cerebral diseases, which is non-invasive, miniaturized, and low-cost. A total of 25 rabbits were studied using a two-coil sensor with a 0.3-200 MHz frequency range, and all the subjects were measured for 1 hour. Based on the rabbit acute cerebral ischemia model, the rabbits were divided into unilateral ligation, bilateral ligation, and non-ligation groups. The results showed that the average MIPS values of the non-ligation, unilateral ligation, and bilateral ligation group were -0.195 ± 0.079°, -4.873 ± 1.042°, and -9.165 ± 2.862° respectively. MIPS distinguished different severities of cerebral ischemia in rabbits with statistical significance (p <; 0.05). Laser Doppler flowmetry (LDF) was used as the gold standard for collecting cerebral blood flow data. The strong correlation between the LDF measurements and the phase shift suggested that the phase shift reflects blood flow changes in the brain. Overall, these results suggest that the MIPS detection method has the potential to provide early detection of global cerebral ischemia. Furthermore, this method effectively distinguished different severities of cerebral ischemia.

9 June 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GJGui Jin
Gui Jin
CXChuanqian Xia
Chuanqian Xia
FWFeng Wang
Feng Wang
LYLian Yan
Lian Yan
CZChen Zhou
Chen Zhou
JSJian Sun
Jian Sun
Stroke is a leading cause of mortality and disability worldwide, with rapid diagnosis critical for effective intervention. Conventional imaging modalities such as CT and MRI are limited by their size, cost, and unsuitability for bedside or prehospital emergency use. This study presents a novel Superparamagnetic Iron Oxide Nanoparticles (SPIOs) based Magnetic Induction Tomography (SPIO-MIT) for non-invasive stroke-tracing imaging. Operating at an ultra-low excitation frequency of 3 kHz and a magnetic field strength below 1 mT, the system effectively suppresses background interference from biological tissues while enhancing sensitivity to SPIOs distribution. System performance was validated through phantom experiments featuring varied SPIOs positions, geometries, and concentration gradients, confirming accurate imaging of SPIOs with negligible response to low-conductivity substances. Complementary in vitro experiments embedding SPIO-blood mixtures in biological tissues demonstrated minimal background interference. In vivo experiments on a rabbit intracerebral hemorrhage model further confirmed precise localization of SPIOs injected into the brain, with detection sensitivity down to 1.2 mg of iron and an imaging diameter of 60 mm. In summary, the developed SPIO-MIT system enables sensitive, non-invasive spatial mapping of SPIOs. By combining the high sensitivity of magnetic particle imaging with the operational simplicity and biological safety of magnetic induction tomography, SPIO-MIT represents a promising technique for portable, bedside, and prehospital stroke diagnostics.