Philipp Seeböck

Philipp Seeböck

Auto-generated profile, based on publicly available information

Philipp Seeböck

Medical University of Vienna

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
NMNathaniel Mercaldo
Nathaniel Mercaldo
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
BBBettina Baeßler
Bettina Baeßler
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical

31 May 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PSPhilipp Seebock
Philipp Seebock
JOJose Ignacio Orlando
Jose Ignacio Orlando
TSThomas Schlegl
Thomas Schlegl
SWSebastian M. Waldstein
Sebastian M. Waldstein
HBHrvoje Bogunović
Hrvoje Bogunović
USUrsula Schmidt-Erfurth
Ursula Schmidt-Erfurth
Diagnosis and treatment guidance are aided by detecting relevant biomarkers in medical images. Although supervised deep learning can perform accurate segmentation of pathological areas, it is limited by requiring a-priori definitions of these regions, large-scale annotations, and a representative patient cohort in the training set. In contrast, anomaly detection is not limited to specific definitions of pathologies and allows for training on healthy samples without annotation. Anomalous regions can then serve as candidates for biomarker discovery. Knowledge about normal anatomical structure brings implicit information for detecting anomalies. We propose to take advantage of this property using bayesian deep learning, based on the assumption that epistemic uncertainties will correlate with anatomical deviations from a normal training set. A Bayesian UNet is trained on a well-defined healthy environment using weak labels of healthy anatomy produced by existing methods. At test time, we capture epistemic uncertainty estimates of our model using Monte Carlo dropout. A novel post-processing technique is then applied to exploit these estimates and transfer their layered appearance to smooth blob-shaped segmentations of the anomalies. We experimentally validated this approach in retinal optical coherence tomography (OCT) images, using weak labels of retinal layers. Our method achieved a Dice index of 0.789 in an independent anomaly test set of age-related macular degeneration (AMD) cases. The resulting segmentations allowed very high accuracy for separating healthy and diseased cases with late wet AMD, dry geographic atrophy (GA), diabetic macular edema (DME) and retinal vein occlusion (RVO). Finally, we qualitatively observed that our approach can also detect other deviations in normal scans such as cut edge artifacts.

22 October 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PSPhilipp Seebock
Philipp Seebock
SWSebastian M. Waldstein
Sebastian M. Waldstein
SKSophie Klimscha
Sophie Klimscha
HBHrvoje Bogunović
Hrvoje Bogunović
TSThomas Schlegl
Thomas Schlegl
GLGeorg Langs
Georg Langs
The identification and quantification of markers in medical images is critical for diagnosis, prognosis, and disease management. Supervised machine learning enables the detection and exploitation of findings that are known a priori after annotation of training examples by experts. However, supervision does not scale well, due to the amount of necessary training examples, and the limitation of the marker vocabulary to known entities. In this proof-of-concept study, we propose unsupervised identification of anomalies as candidates for markers in retinal Optical Coherence Tomography (OCT) imaging data without a constraint to a priori definitions. We identify and categorize marker candidates occurring frequently in the data, and demonstrate that these markers show predictive value in the task of detecting disease. A careful qualitative analysis of the identified data driven markers reveals how their quantifiable occurrence aligns with our current understanding of disease course, in early- and late age-related macular degeneration (AMD) patients. A multiscale deep denoising autoencoder is trained on healthy images, and a one-class support vector machine identifies anomalies in new data. Clustering in the anomalies identifies stable categories. Using these markers to classify healthy-, early AMD- and late AMD cases yields an accuracy of 81.40%. In a second binary classification experiment on a publicly available data set (healthy vs. intermediate AMD) the model achieves an AUC of 0.944.

1 January 2022 in Progress in Retinal and Eye Research
Verified
Journal Article
Open access
USUrsula Schmidt-Erfurth
Ursula Schmidt-Erfurth
GRGregor S. Reiter
Gregor S. Reiter
SRSophie Riedl
Sophie Riedl
PSPhilipp Seeböck
Philipp Seeböck
WVWolf-Dieter Vogl
Wolf-Dieter Vogl
HBHrvoje Bogunović
Hrvoje Bogunović
Retinal fluid as the major biomarker in exudative macular disease is accurately visualized by high-resolution three-dimensional optical coherence tomography (OCT), which is used world-wide as a diagnostic gold standard largely replacing clinical examination. Artificial intelligence (AI) with its capability to objectively identify, localize and quantify fluid introduces fully automated tools into OCT imaging for personalized disease management. Deep learning performance has already proven superior to human experts, including physicians and certified readers, in terms of accuracy and speed. Reproducible measurement of retinal fluid relies on precise AI-based segmentation methods that assign a label to each OCT voxel denoting its fluid type such as intraretinal fluid (IRF) and subretinal fluid (SRF) or pigment epithelial detachment (PED) and its location within the central 1-, 3- and 6-mm macular area. Such reliable analysis is most relevant to reflect differences in pathophysiological mechanisms and impacts on retinal function, and the dynamics of fluid resolution during therapy with different regimens and substances. Yet, an in-depth understanding of the mode of action of supervised and unsupervised learning, the functionality of a convolutional neural net (CNN) and various network architectures is needed. Greater insight regarding adequate methods for performance, validation assessment, and device- and scanning-pattern-dependent variations is necessary to empower ophthalmologists to become qualified AI users. Fluid/function correlation can lead to a better definition of valid fluid variables relevant for optimal outcomes on an individual and a population level. AI-based fluid analysis opens the way for precision medicine in real-world practice of the leading retinal diseases of modern times.


8 February 2024 in Medical Image Analysis
Verified
Journal Article
Open access
PSPhilipp Seeböck
Philipp Seeböck
JOJosé Ignacio Orlando
José Ignacio Orlando
MMMartin Michl
Martin Michl
JMJulia Mai
Julia Mai
USUrsula Schmidt-Erfurth
Ursula Schmidt-Erfurth
HBHrvoje Bogunović
Hrvoje Bogunović
Automated lesion detection in retinal optical coherence tomography (OCT) scans has shown promise for several clinical applications, including diagnosis, monitoring and guidance of treatment decisions. However, segmentation models still struggle to achieve the desired results for some complex lesions or datasets that commonly occur in real-world, e.g. due to variability of lesion phenotypes, image quality or disease appearance. While several techniques have been proposed to improve them, one line of research that has not yet been investigated is the incorporation of additional semantic context through the application of anomaly detection models. In this study we experimentally show that incorporating weak anomaly labels to standard segmentation models consistently improves lesion segmentation results. This can be done relatively easy by detecting anomalies with a separate model and then adding these output masks as an extra class for training the segmentation model. This provides additional semantic context without requiring extra manual labels. We empirically validated this strategy using two in-house and two publicly available retinal OCT datasets for multiple lesion targets, demonstrating the potential of this generic anomaly guided segmentation approach to be used as an extra tool for improving lesion detection models.